Take control of everyday comfort with the Vaillant sensoHOME VRT380 wired room thermostat. Designed for compatible Vaillant eBUS heating systems, it combines a clear touch interface with flexible weekly programming, helping homeowners match heating to their routine while giving installers dedicated commissioning and configuration tools.
Set individual comfort temperatures with up to 12 heating periods per day, make temporary adjustments and manage domestic hot water where supported by the installed system. Its wired eBUS connection enables modulating control, allowing the heating system to adjust its operation to demand rather than relying solely on basic on/off switching.
12 per day
Heating periods
Class III
Electrical protection
Installation safety: Electrical installation must be carried out by a qualified electrician. The heating installation must be decommissioned before work begins. Use the specified eBUS connection and follow the installation instructions.
Compatibility: This is the wired VRT380, not the wireless VRT 380f. It is intended for compatible Vaillant eBUS heat generators, it is not a universal replacement for a mains switching thermostat. Available functions depend on the installed system.
ErP documentation difference: The product data sheet lists control class V and a 3.0% contribution to seasonal room heating efficiency. The installation manual lists class VI and 4.0% for weather compensated control with the room thermostat function enabled. These are configuration dependent figures, not guaranteed energy bill savings, confirm the applicable classification for the installation.
Positioning tip: Keep the room thermostat clear of furniture and curtains. Where it controls the room temperature, the manual instructs users to keep that room’s thermostatic radiator valves fully open.
Key features
Modulating eBUS control
The wired eBUS interface supports modulating control of compatible Vaillant heating equipment, helping match heat delivery to the system’s requirements.
Flexible weekly schedules
Create up to 12 heating periods per day, each with its own desired temperature. Set back settings manage heating outside scheduled periods.
Straightforward touch interface
Use the touch controls to navigate menus, adjust temperatures and access help. A button lock helps prevent unintended changes.
Guided commissioning
The installation assistant guides the installer through configuration. Dedicated installer settings allow the control to be matched to the heating installation.
Hot water management
Control domestic hot water schedules and request a one off cylinder boost where the system supports these functions. Hot water and circulation planners each allow up to three periods per day.
Weather compensated operation
With a suitable outdoor temperature sensor, the control can use weather compensation and an installer configured heat curve to adjust target flow temperature.
Technical specifications
Product identification
Manufacturer part number
0020260951
Product type
Programmable wired room thermostat / system control
Electrical and protection
Communication
Vaillant eBUS
Rated current
Less than 50 mA
Rated surge voltage
330 V
Supply conductor cross-section
0.75-1.5 mm²
Maximum bus cable length
125 m
Dimensions and operating environment
Dimensions (H × W × D)
109 × 175 × 26 mm
Permitted ambient temperature
0-60 °C
Ball pressure test temperature
75 °C
Installation
Wall mounted, do not install in rooms prone to frost
Programming and system functions
Heating weekly planner
Up to 12 time periods and desired temperatures per day
Domestic hot water weekly planner
Up to 3 time periods per day, system dependent
Circulation weekly planner
Up to 3 time periods per day, system dependent
Heating modes
Manual, time controlled and off
Additional functions
Absence, domestic hot water boost, ventilation boost and button lock, availability depends on system configuration
Weather compensation
Requires a suitable connected outdoor temperature sensor
Heat curve adjustment
0.1-4.0
Compatibility
Compatible Vaillant heat generators with eBUS, system design and commissioning determine supported functions
Compliance and energy classification
CE marking
Confirmed in operating and installation instructions
ErP product data sheet
Class V, 3.0% seasonal room heating efficiency contribution
Manual: weather-compensated configuration
Class VI, 4.0% contribution with room thermostat function enabled, see documentation callout
Frequently asked questions
Is the sensoHOME VRT 380 wired or wireless?
The VRT 380 is wired and communicates through Vaillant eBUS. It should not be confused with the VRT 380f wireless version.
Will this thermostat work with any boiler?
No. It is intended for compatible Vaillant heat generators with an eBUS interface. Ask your installer to check the exact boiler and system configuration before ordering; it is not a universal mains switching thermostat.
Can I set different heating temperatures throughout the day?
Yes. The weekly planner supports up to 12 heating periods per day, each with its own desired temperature. Outside these periods, operation follows the configured set-back mode.
Can it control my hot water as well as the heating?
On suitable systems, it provides domestic hot water scheduling, circulation scheduling and a one off cylinder boost. These functions depend on the connected equipment and installation configuration.
Does weather compensation require an outdoor sensor?
Yes. Weather compensated control requires a suitable connected outdoor temperature sensor. The installer configures the heat curve and relevant room temperature settings for the building.
Where should the room thermostat be installed?
Install the wall mounted control in an appropriate room according to the manual, away from obstructions such as curtains and furniture. Do not install it in a room prone to frost; electrical installation requires a qualified electrician.