Boiler Buying Guide & Kit Builder

Choose a boiler and everything it needs, in one basket

Tell us your fuel, your home and how you use hot water. The builder picks the right boiler type and size from our live range, then adds the cylinder, flue, filter, valves, controls and safety parts an installer will expect to find on site.

What will the boiler run on?

This decides which boilers, flues and safety parts apply.

Your parts list

Each line says why it’s there. Untick what you don’t need, change quantities or swap a product, then add the kit to your basket.

    Gas, LPG or electric?

    All three heat water and pump it round the same radiators or underfloor pipes. What changes is the fuel bill, what has to be fitted around the boiler, and who is allowed to install it.

    Mains gas

    Still the cheapest way to run a wet heating system in most UK homes with a gas meter. Every gas boiler needs a flue, a condensate drain, a carbon monoxide alarm and a Gas Safe engineer to fit and register it.

    Shop gas boilers

    LPG

    For homes off the gas grid. Many gas boilers run on LPG once the maker’s conversion kit is fitted, and some ship LPG-ready. Fuel costs more per kWh than mains gas, so efficiency and good controls matter more.

    Shop LPG boilers

    Electric

    No flue, no combustion and no annual gas safety check. Close to 100% efficient at the point of use and silent, but electricity costs more per kWh than gas. Best for flats, smaller or well-insulated homes, off-peak tariffs and homes with solar PV.

    Shop electric boilers

    Combi, system or heat-only

    The boiler type follows your hot water and your pipework, not the other way round. Getting this wrong is the most expensive mistake on a boiler order, because the types aren’t interchangeable.

    Combi System Heat-only (regular)
    Hot water On demand, no cylinder Stored in a cylinder Stored in a cylinder
    Heating system Sealed Sealed Open-vented, or sealed with an added vessel
    Loft tanks None None Feed & expansion tank (and cold tank for a vented cylinder)
    Built-in pump and vessel Yes Yes Usually not
    Two showers at once Struggles Yes Yes
    Best for Flats and 1-bathroom homes Family homes, 2+ bathrooms Like-for-like swaps on older systems

    How to tell what you have now

    Look in the loft. A small tank feeding the heating, usually beside a larger cold water tank, means an open-vented system: a heat-only boiler is the like-for-like swap. A pressure gauge on or near the boiler and a filling loop, with no heating tank in the loft, means a sealed system, which suits a system boiler or a combi.

    Browse by type: gas combi, gas system, gas heat-only, electric combi, electric system and electric heat-only.

    Sizing a boiler

    A boiler needs to cover two loads: the heat your home loses on a cold day, and, for a combi, the hot water you draw at once. The builder estimates heat loss from floor area and insulation. An installer’s room-by-room calculation is the figure to size on.

    Gas and LPG

    Gas combis are sized on hot water, because heating water instantly for a shower needs far more power than heating most homes. Around 24–28kW suits one bathroom, 30–35kW suits a bathroom plus an en-suite. Beyond that, a system boiler and cylinder serves better. Gas system and heat-only boilers are sized on heat loss plus a little for the cylinder. They modulate down well, so a 15–25kW model covers most homes.

    Electric

    Electric boilers are sized tightly to heat loss, because every kW is current your supply has to carry. Most single-phase models top out at 14.4kW, which draws about 63A and needs its own circuit. Bigger loads need a three-phase supply.

    Electric combi hot water: expect roughly 0.41 litres a minute for every kW. A 14.4kW combi gives about 5.9 L/min, enough for one modest shower. If two people shower at once, choose a system boiler and cylinder, or a direct cylinder heated on an off-peak tariff.

    Do you need a cylinder?

    It depends on what the boiler supplies and how much hot water you use at once.

    • Radiators, one bathroom: a combi is simplest. Add a cylinder if you have a large bath or regularly run two outlets together.
    • Underfloor heating: UFH runs at low temperatures for long periods, leaving the boiler free to reheat a cylinder between cycles. A system boiler with a cylinder is the usual pairing in larger homes. Large UFH systems hold a lot of water, so the builder adds an extra expansion vessel.
    • Hot water only: a combi or gas water heater makes it on demand. With electricity, a direct unvented cylinder with immersion heaters does the job with no boiler at all.
    • Two or more bathrooms: a cylinder, almost always.
    Household Typical cylinder
    1–2 bedrooms, 1 bathroom 150L
    3–4 bedrooms, 1 bathroom 180L
    2 bathrooms 210L
    3 bathrooms 250L
    4+ bathrooms 300L

    Unvented cylinders run at mains pressure for strong showers but need a G3-qualified installer and decent mains flow. Vented cylinders are fed from a loft tank and are the simple swap on older systems. Pre-plumbed cylinders arrive with the zone valves and wiring centre fitted. See all boiler cylinders.

    The parts a boiler can’t do without

    A boiler arrives as a box. These are the parts that turn it into a working, compliant installation, and the ones manufacturers check before honouring a warranty.

    Magnetic filter

    Catches the magnetite sludge that kills heat exchangers and pumps. Most manufacturers make an in-line filter a warranty condition. Boiler filters

    Cleaner and inhibitor

    Flush the old system before the new boiler goes on, then dose inhibitor to stop corrosion. Cleaning and inhibiting to BS 7593 is a typical warranty requirement. Heating chemicals

    Flue

    Gas and LPG only. Each flue system is certified with its own brand of boiler, so a Vaillant needs a Vaillant flue and a Worcester a Worcester flue. Plume kits redirect the vapour away from windows and boundaries. Flues and accessories

    Expansion vessel and filling loop

    Combis and system boilers have them built in. Heat-only boilers don’t, so a sealed installation needs a vessel and a Part L filling kit. Large underfloor systems may need extra vessel capacity. Vessel & filling kit, expansion vessels

    Circulating pump

    Built into combis and system boilers. Heat-only boilers need an external pump; underfloor manifolds often bring their own. Heating pumps

    Zone valves and bypass

    With a system or heat-only boiler, motorised valves split heating and hot water (S-plan). An automatic bypass keeps minimum flow through the boiler when valves close. Plumbing valves

    Controls

    Part L requires time and temperature control. For Vaillant boilers we pair Vaillant’s own controller, which talks to the boiler directly for load and weather compensation. Part L thermostats

    Scale reducer

    In hard water areas (above 200ppm), combis and hot water systems need scale protection under Building Regulations guidance. Scale inhibitors

    Carbon monoxide alarm

    Required by Building Regulations in the room where a gas or LPG boiler is fitted. Electric boilers don’t burn fuel, but a heat alarm near the cupboard is sensible. Alarms

    Regulations and sign-off

    • Gas Safe: any gas or LPG boiler must be installed by a Gas Safe registered engineer, who registers it with Building Control. That registration is usually needed for the warranty too.
    • Part L and Boiler Plus (England): new boilers need time and temperature controls, and TRVs on radiators where there’s no room thermostat. A new gas combi also needs one extra measure: weather compensation, load compensation, flue gas heat recovery, or a smart thermostat with automation and optimisation. Part L also asks for new systems to be designed for a flow temperature of 55°C or lower where practical.
    • Part J: a carbon monoxide alarm is required when a fixed combustion appliance, such as a gas or LPG boiler, is installed or replaced.
    • Part G3: unvented hot water cylinders must be fitted by a G3-qualified installer.
    • Part P: an electric boiler on a new circuit is notifiable electrical work, carried out by a registered electrician.

    Scotland, Wales and Northern Ireland have their own versions of these rules. Your installer will confirm what applies locally. See also our guide to meeting Part L.

    Boiler buying FAQs

    What size boiler do I need?

    For a gas combi, size on hot water: 24–28kW for one bathroom, 30–35kW for two. For system and heat-only boilers, size on your home’s heat loss plus a little for the cylinder. For electric boilers, size closely to heat loss, as most single-phase models stop at 14.4kW. The kit builder estimates this from floor area and insulation; confirm it with an installer’s heat loss survey.

    Can an electric combi run a shower?

    One modest shower, yes. An electric combi delivers about 0.41 litres a minute per kW, so a 14.4kW single-phase model gives roughly 5.9 L/min. For two outlets at once, a system boiler with a cylinder, or a three-phase combi, is the better choice.

    Do I need a cylinder with underfloor heating?

    Not necessarily: a combi can run underfloor heating. But UFH runs for long periods at low temperature, which leaves time to reheat a cylinder, and larger homes with UFH usually have more than one bathroom. With two or more bathrooms, choose a system boiler and cylinder.

    Can I replace an open-vented system with a combi?

    Yes, but it means converting to a sealed system: removing the loft tanks and cylinder, and checking that old pipework and radiators can take mains pressure. If you’d rather keep the existing pipework, a heat-only boiler is the like-for-like swap.

    Is a magnetic filter required for the boiler warranty?

    For most manufacturers, yes. A filter, plus cleaning and inhibiting the system to BS 7593, is a common condition of extended warranties. Check the terms for your boiler, and keep the commissioning checklist (Benchmark) your installer completes.

    Can I use any flue with my gas boiler?

    No. Flues are tested and certified with a specific brand’s boilers, so you need the same manufacturer’s flue kit, extensions and plume kit. Many boilers we sell include a horizontal flue; the kit builder only adds a flue when it isn’t already in the box.

    Do I need a carbon monoxide alarm?

    For a gas or LPG boiler, yes. Building Regulations require a CO alarm in the room when a fixed combustion appliance is installed or replaced. Electric boilers don’t burn fuel, so a CO alarm isn’t required for them.

    Can a natural gas boiler run on LPG?

    Many can, using the manufacturer’s LPG conversion kit, fitted and commissioned by a Gas Safe engineer. Some models ship with the kit included. Check the boiler’s LPG approval before you order.

    Why does the builder pick a Vaillant controller for Vaillant boilers?

    Vaillant boilers communicate with Vaillant controls over their own eBUS connection, which unlocks load and weather compensation. That helps meet Part L and Boiler Plus and gets the most from the boiler’s modulation. You can still swap it in the parts list.

    Can I run an electric boiler from solar panels?

    Yes. Many electric boilers can be range-rated or have multiple outputs to match available solar power, and a diverter can send surplus PV to a cylinder’s immersion heater. Read our guide to running an electric boiler with solar panels.

    More buying guides