The SolaX X1-MINI G4 1.1kW single phase string inverter is an ultra-compact, fanless grid-tied inverter built for small PV arrays, balcony installations and tight mounting spaces. At 5.2 kg and smaller than an A4 sheet, it pairs a single MPP tracker with a 40–450 V MPPT range, a 16 A input and up to 200% PV oversizing so modern high-power modules can be used without an oversized inverter.
Global MPP scanning with shade optimisation keeps yields up on partially shaded roofs, while the IP66 enclosure, natural convection cooling and Type II surge protection on both the AC and DC side make it a quiet, low-maintenance choice for outdoor and outbuilding installs. With a 1,100 W AC rating it is well suited to small roofs, sheds, garages and low-demand homes.
The inverter includes a built-in export power control function, supports parallel operation of up to 5 inverters without an external EMS, and offers smart loads management for devices such as heat pumps and smart EV chargers. It is supplied with WiFi and is available with AFCI arc-fault detection for the DC side.
1.1 kW
Rated AC output
2.2 kWp
Max recommended PV
40–450 V
MPPT voltage range
16 A
Max input current
98%
Max efficiency
IP66
Outdoor rated
Important Safety Information
Installation must be carried out by a competent, qualified person in accordance with BS 7671 and the manufacturer's installation manual. The DC side carries dangerous voltage whenever the array is illuminated. Isolate both AC and DC before opening the inverter.
Grid Connection (G98 / G99)
The X1-MINI G4 range is certified to G98 and G99. Notify or apply to the DNO as required before or after commissioning, and confirm the country code is set correctly for the UK. Where export limiting is required, use the built-in export control together with a compatible meter or CT (sold separately).
Monitoring & Connectivity
Connect to SolaXCloud via the supplied WiFi for monitoring and firmware updates. The datasheet lists 10 second data refresh as an option with the newer WiFi dongle, and the inverter provides I-V curve diagnosis to help identify string or module faults.
Ultra-Compact & Fanless
Only 5.2 kg and 290 × 206 × 120 mm, with natural convection cooling for silent operation and no fan to fail.
200% PV Oversizing
16 A input and up to 200% DC oversizing let you match high-power modules and start generating earlier in the morning and later in the evening.
Ultra-Wide MPPT Range
A 40–450 V MPPT range with global MPP scan and shade optimisation holds yield through changing conditions.
Type II Surge Protection
Type II SPD on the AC and DC side protects the inverter and your installation from voltage spikes.
Parallel Operation
Run up to 5 inverters in parallel with no external EMS, so the system scales as your needs grow.
Smart Loads & Export Control
Built-in export power control and smart loads management for heat pumps and EV chargers help you use more of what you generate.
PV Input
Max. recommended PV array power
2.2 kWp
Max. PV input voltage
450 V
Start-up voltage
50 V
Rated PV input voltage
360 V
Operating voltage range
35–450 V
MPPT voltage range
40–450 V
No. of MPP trackers / strings per tracker
1 / 1
Max. input current per MPPT
16 A
Max. input short-circuit current per MPPT
22 A
AC Output
Rated output power
1,100 W
Rated output current
4.8 A
Max. output apparent power
1,210 VA
Max. output continuous current
5.5 A
Rated AC voltage
1 / N / PE, 220 / 230 / 240 V
AC frequency
50 / 60 Hz (±5 Hz)
Adjustable power factor range
0.8 leading to 0.8 lagging
THDi (rated power)
< 3%
Efficiency
Max. efficiency
98%
European efficiency
97%
Night-time consumption
< 1 W
General
Ingress protection
IP66
Protection class
Class I
Overvoltage category
II (DC), III (AC)
Operating temperature range
-25 to +60 °C
Max. operating altitude
< 4,000 m
Relative humidity
0–100%
Dimensions (W × H × D)
290 × 206 × 120 mm
Net weight
5.2 kg
Cooling
Natural convection
Communication interfaces
USB / RS485 / DRM; optional meter / CT
Monitoring
Supplied WiFi dongle; SolaXCloud and app
Display
2 × LED + LCD (16 × 2) / app
Surge protection (DC / AC)
Type II / Type II
Arc-fault circuit interrupter (AFCI)
Optional
Standard warranty
5 years
Standards & Certification
Safety
EN/IEC 62109-1/2
EMC
EN 61000-6-1/2/3/4; EN 61000-3-2/3/11/12
Grid codes
G98, G99, EN 50549, IEC 61727, VDE 4105, CEI 0-21, AS 4777.2, VFR
What is the maximum PV array I can connect to the 1.1kW model?
The datasheet gives a maximum recommended PV array power of 2.2 kWp. This equals 200% of the 1.1 kW AC rating. The single MPP tracker accepts up to 16 A input current and 22 A short-circuit current, with a 450 V maximum input voltage.
Is this inverter suitable for a balcony or tight space?
Yes. At 290 × 206 × 120 mm and 5.2 kg it is smaller than an A4 sheet, fanless and IP66 rated, so it can be wall mounted in confined or outdoor locations.
Does it meet UK grid connection requirements?
The X1-MINI G4 range is certified to G98 and G99. Whether you need to notify the DNO or apply for approval depends on the total installed generating capacity at the premises, so check the requirements for your installation before commissioning.
Can I limit export to the grid?
Yes. The inverter has a built-in export power control function. Export limiting relies on a compatible meter or CT, which is sold separately. A SolaX single phase Chint meter with CT is suitable for this.
Can several inverters be used together?
Yes. The X1-MINI G4 supports parallel operation of up to 5 inverters without an external EMS.
What warranty does it carry?
SolaX lists a 5 year standard warranty for the X1-MINI G4 range under its UK warranty terms. Keep your invoice and commissioning details, and register the inverter on SolaXCloud.