The Panasonic CU-2Z35CBE is a 3.5kW R32 Free Multi System Z outdoor unit with two refrigerant ports, letting one compact condenser heat and cool two separate rooms with individual control of each indoor unit. It delivers 3.50kW nominal cooling and 4.20kW nominal heating, with a seasonal efficiency of SEER 9.10 (A+++) in cooling and SCOP 4.80 (A++) in heating.
Built for installers specifying a multi-split system, it supports total connected indoor capacity of 3.2 to 6.0kW, pipe runs of up to 30m in total and 20m to a single indoor unit, and heating operation down to -15°C outdoor ambient. The R2 rotary inverter compressor carries a 5-year compressor warranty, and the R32 refrigerant keeps the system's CO₂ equivalent to just 0.797 tonnes.
2 Ports
Two-room multi-split
48 dB(A)
Sound pressure (cooling)
Safety and regulatory
R32 is a mildly flammable (A2L) refrigerant. Installation, pipework, commissioning and any refrigerant handling must be carried out by F-Gas certified engineers in line with Panasonic's installation instructions and current UK regulations. Electrical connection must comply with BS 7671.
Compatibility: outdoor unit only, minimum two indoor units
This listing is for the outdoor unit only. Indoor units are supplied separately and at least two indoor units must be connected, with a combined nominal capacity between 3.2kW and 6.0kW. Some indoor unit combinations require a pipe reducer (CZ-MA1PA), and the floor console is compatible only with 2-port outdoor units. Always check your chosen pairing against Panasonic's combination matrix before ordering.
Good to know: A+++ cooling efficiency
With SEER 9.10 and a nominal cooling EER of 4.61, the CU-2Z35CBE sits in the top A+++ energy class for cooling, while SCOP 4.80 and a nominal heating COP of 5.06 deliver A++ heating efficiency.
Key Features
A+++ / A++ Efficiency
SEER 9.10 (A+++) and SCOP 4.80 (A++) keep running costs low, with a rated annual consumption of 135 kWh/a cooling and 933 kWh/a heating.
Two Rooms, One Outdoor Unit
Two ports serve two rooms with individual indoor control, avoiding two separate outdoor units on the wall and the extra pipework and electrics that brings.
Wide Indoor Unit Choice
The Free Multi System Z range pairs with Etherea and TZ super-compact wall units, floor console, 4-way 60x60 cassette and low static pressure hide-away indoor units, so each room gets the right format.
Heating Down to -15°C
Rated for heating operation from -15°C to +24°C and cooling from -10°C to +46°C, with 3.77kW heating capacity at -7°C for reliable winter output.
Flexible Pipe Runs
30m total pipe length, 20m to any one indoor unit and 10m elevation difference. The outdoor unit is pre-charged for 20m, with additional gas only needed beyond that.
Compact and Quiet
At just 619 x 824 x 299mm and 37kg, it suits wall brackets and tight plant areas, with 48 dB(A) sound pressure in cooling and 50 dB(A) in heating.
Technical Specifications
General
Range
Free Multi System Z · R32
Type
Multi-split inverter outdoor unit, heat pump (cooling and heating)
Connectable rooms (ports)
2
Connectable indoor capacity range
3.2 ~ 6.0 kW
Compressor
R2 rotary inverter, 5-year compressor warranty
Cooling Performance
Cooling capacity (nominal / min / max)
3.50 / 1.50 / 4.50 kW
Input power (nominal / min / max)
0.76 / 0.25 / 1.10 kW
EER (nominal / min / max)
4.61 / 6.00 / 4.09 W/W
Pdesign (cooling)
3.50 kW
Annual energy consumption (cooling)
135 kWh/a
Heating Performance
Heating capacity (nominal / min / max)
4.20 / 1.10 / 5.60 kW
Heating capacity at -7°C
3.77 kW
Input power (nominal / min / max)
0.83 / 0.21 / 1.34 kW
COP (nominal / min / max)
5.06 / 5.24 / 4.18 W/W
Annual energy consumption (heating)
933 kWh/a
Electrical
Running current (cooling / heating)
3.60 / 3.90 A
Recommended power cable section
2.5 mm²
Sound and Dimensions
Sound pressure, high (cooling / heating)
48 / 50 dB(A)
Dimensions (H x W x D)
619 x 824 x 299 mm
Refrigerant and Piping
Refrigerant charge
1.18 kg
CO₂ equivalent
0.797 tonnes
Liquid pipe diameter
1/4 inch (6.35 mm)
Gas pipe diameter
3/8 inch (9.52 mm)
Total pipe length range
6 ~ 30 m
Pipe length to one indoor unit
3 ~ 20 m
Elevation difference (indoor / outdoor)
10 m
Pre-charged pipe length
20 m
Additional gas amount
15 g/m beyond 20 m
Operating Range
Cooling mode (outdoor ambient)
-10°C to +46°C
Heating mode (outdoor ambient)
-15°C to +24°C
Frequently Asked Questions
How many indoor units can I connect to the CU-2Z35CBE?
It is a 2-port outdoor unit, so it serves two rooms. At least two indoor units must be connected, and their combined nominal capacity should fall within 3.2 to 6.0kW.
Are indoor units included?
No. This is the outdoor unit only. Indoor units, pipework, condensate drainage and any required pipe adaptors are supplied separately, so you can choose the right format for each room.
What pipe lengths and heights are permitted?
Total pipe length across both rooms is 6 to 30m, with 3 to 20m to any single indoor unit (minimum 3m per indoor unit). The maximum elevation difference between indoor and outdoor units is 10m. The unit is pre-charged for 20m, and 15g of additional R32 per metre is needed beyond that.
Do I need pipe reducers or expanders?
It depends on the indoor units chosen. Panasonic's combination matrix marks some pairings as requiring the CZ-MA1PA pipe reducer, and other models in the range use the CZ-MA2PA expander or CZ-MA3PA reducer. Check the matrix for your exact indoor unit sizes before ordering.
What electrical supply does it need?
It runs from a 230V supply. Panasonic recommends a 16A fuse and 2.5mm² power cable, with a running current of 3.60A in cooling and 3.90A in heating. Wiring must comply with BS 7671.
Do I need to be F-Gas certified to buy and install this unit?
Yes. The CU-2Z35CBE uses R32 refrigerant, so F-Gas certification is required for installation and refrigerant handling, and we verify certification before supplying. Use the button at the top of this page to submit your certificate.