The Joule Cyclone Plus Indirect Standard is a mains-pressure unvented hot water cylinder built around a high-grade Duplex stainless steel vessel, engineered for use with a gas or oil boiler, a heat pump, or any other indirect heat source. Available in seven capacities from 90L to 300L, it's sized for anything from a compact flat to a large family home with multiple bathrooms.
Every cylinder in the range shares the same core engineering: a smooth-tube primary coil for fast, efficient heat transfer, 100% CFC/HCFC-free polyurethane insulation to keep standing losses low, and a factory-fitted 3kW immersion heater for electric backup. The cylinder is finished in a white outer case and supplied with a full unvented safety kit, so it arrives ready to plumb in rather than requiring separate parts sourcing.
|
90-300L
Capacity range
|
Duplex SS
Stainless steel grade
|
3kW
Factory-fitted immersion
|
Class B/C
ErP energy rating
|
25 Yr
Cylinder warranty
|
10 Bar
Test pressure
|
|
Duplex Stainless Steel Vessel
The cylinder body is manufactured from high-grade Duplex stainless steel, chosen for its high mechanical strength and resistance to stress and crevice corrosion — the two failure modes that shorten the life of lower-grade cylinders in hard water areas.
|
Smooth-Tube Primary Coil
A high-performance smooth-tube coil gives faster reheat times and better heat transfer than a corrugated coil of the same size, so hot water recovers quicker after heavy use and the boiler or heat pump runs for less time per cycle.
|
|
Factory-Fitted 3kW Immersion
Every cylinder ships with a 3kW Incoloy immersion heater with an integral thermostat already fitted, giving you a reliable electric backup for hot water during a boiler outage or for topping up on an off-peak tariff.
|
Low Standing-Loss Insulation
50mm-thick, 100% CFC-free polyurethane foam insulation (ODP 0) wraps the vessel to minimise heat loss between draw-offs, which is what actually drives the ErP energy rating rather than the coil alone.
|
|
Complete Unvented Safety Kit
The cylinder is supplied with its full inlet control group, expansion vessel, T&P relief valve, tundish, and dual cylinder thermostat — everything a G3-qualified installer needs is in the box, with nothing to source separately.
|
Front-Access Plumbing
All hot, cold, coil, and safety connections are screwed with 22mm compression fittings and grouped at the front of the cylinder, which keeps the installation faster and means the unit can sit close to a wall.
|
| Construction | |
| Cylinder Material | Duplex Stainless Steel (LDX 2101 grade) |
| Insulation | 100% CFC/HCFC-free polyurethane foam, 50mm thick |
| Insulation ODP | 0 (zero ozone depletion potential) |
| Outer Casing | White outer case, grey polycarbonate T&P safety cover |
| Coil Type | Smooth-tube, high-efficiency primary coil |
| Standard Test | BS EN 12897:2006 |
| Heating & Electrical | |
| Immersion Heater | 3kW Incoloy, factory-fitted with integral thermostat |
| Immersion Supply | 230V single-phase |
| Heat Source | Indirect — gas/oil boiler, heat pump, or compatible heat source |
| Pressure & Safety | |
| Max. Operating Pressure | 3 bar (unvented kit as supplied) |
| T&P Relief Valve Setting | 7 bar / 90°C |
| Test Pressure | 10 bar |
| Unvented Kit Included | Inlet control group, expansion vessel, T&P valve, tundish, dual cylinder stat |
| Capacity | Product Code | Weight Empty | Weight Full | ErP Class | Reheat Time (Coil) | Standing Loss |
|---|---|---|---|---|---|---|
| 120L | TRJMVI-0120LFB | 30 kg | 146 kg | B | 19.05 min | 46 W |
| 150L | TRJMVI-0150LFB | 38 kg | 184 kg | B | 23.71 min | 53 W |
| 180L | TRJMVI-0180LFB | 42 kg | 218 kg | B | 29.20 min | 58 W |
| 210L | TRJMVI-0210LFC | 45 kg | 248 kg | B | 32.5 min | 62 W |
| 250L | TRJMVI-0250LFC | 51 kg | 296 kg | C | 38.83 min | 73 W |
| 300L | TRJMVI-0300LFC | 60 kg | 355 kg | C | 43.8 min | 85 W |
| Capacity | Height (A) | Diameter (B) | Cold Inlet (C) | Coil Flow (D) | Coil Return (E) | T&P Valve (G) |
|---|---|---|---|---|---|---|
| 120L | 900mm | 545mm | 480mm | 440mm | 200mm | 710mm |
| 150L | 1100mm | 545mm | 560mm | 520mm | 200mm | 890mm |
| 180L | 1280mm | 545mm | 600mm | 560mm | 200mm | 1085mm |
| 210L | 1470mm | 545mm | 640mm | 600mm | 200mm | 1265mm |
| 250L | 1720mm | 545mm | 640mm | 600mm | 200mm | 1520mm |
| 300L | 1980mm | 545mm | 640mm | 600mm | 200mm | 1785mm |