The Intergas Xylinder Heat Pump is an unvented, mains-pressure hot water cylinder built from grade 444 stainless steel and fitted with a large-area smooth internal coil and 28 mm coil connections for heat pump primary circuits. It is available in 150, 180, 200, 250 and 300 litre capacities.
The coil grows with the cylinder, from 1.42 m² on the 150L to 2.98 m² on the 300L, giving manufacturer reheat times of just 13 to 18 minutes. A 3 kW titanium immersion heater sits above the coil, a complete G3 kit is included, and the tank carries a 25-year warranty on mains water. Intergas developed the Xylinder range as part of the Rheem group, working with DeJong, a specialist in hot water cylinders, and built it to last like their boilers.
Grade 444 stainless steel: built to outlast the industry standard
Every Xylinder tank is made from grade 444 stainless steel. The industry standard is Duplex 2304, and Intergas describe grade 444 as one of the highest grades of stainless steel on the market and unique to Intergas, renowned for its superior corrosion resistance.
Extreme corrosion resistance
Resists limescale, chlorine, stress and pitting, the everyday causes of tank failure.
High heat transfer
High heat transfer capability works with the smooth coil for rapid recovery.
Lightweight construction
A lightweight build with a carry handle on the bottom lid makes handling easier.
25-year tank warranty
25 years on the tank with a mains water supply, plus 2 years parts and labour.
Grade 444
Stainless steel tank
1.42–2.98 m²
Coil surface area
28.9–41.7kW
Coil rating by size
13–18 min
Reheat 15°C to 60°C
25-Year
Tank warranty (mains supply)
A bigger coil built for heat pumps
Heat pumps work with lower primary temperatures than boilers, so the coil needs more surface area to transfer the heat. The Xylinder Heat Pump coil is smooth rather than corrugated for better water flow, and is up to nearly four times the area of the 0.78 m² coil on the standard Xylinder Indirect.
Xylinder Indirect (all sizes)
Unvented hot water safety and regulations
Unvented cylinders are a regulated installation (Building Regulations Part G3). Installation, commissioning and servicing must be carried out by a competent, G3-qualified installer, and the Benchmark commissioning record completed. Fit an approved thermostatic mixing valve (TMV Type 2 or 3) so the bath outlet never exceeds 48°C, and keep stored water at 60°C or above to control Legionella.
Match the coil to your heat pump
Coil ratings range from 28.9 to 41.7 kW and the primary pressure drop from 45 to 95 mbar at 1,400 l/h. Check both against your heat pump's output and circulation pump before specifying. The coil has a maximum primary operating pressure of 3 bar and a maximum design pressure of 16 bar.
Warranty conditions to be aware of
The 25-year tank warranty applies to mains-supplied water. On a private supply (well, spring or borehole) the tank warranty is 5 years. All components carry a 2-year parts and labour warranty. Register the cylinder with Intergas on MiREG and keep an annual service record to maintain cover.
Included in the box
Every Xylinder Heat Pump ships with the standard Intergas G3 kit: expansion vessel, dual stat, PRV, inlet group, diverter valve and tundish. The inlet group is WRAS approved, and the complete kit is matched to the cylinder.
Key features
Grade 444 stainless steel tank
Grade 444 stainless steel for extreme corrosion resistance and high heat transfer, where the industry standard is Duplex 2304.
Large smooth coil
A 1.42 to 2.98 m² smooth coil (not corrugated) promotes rapid heat transfer, efficient recovery and better water flow.
Rapid reheat
Manufacturer reheat times of 13 to 18 minutes from 15°C to 60°C, with a primary pressure drop of just 45 to 95 mbar.
Immersion above the coil
The 3 kW titanium immersion heater sits above the coil, so it heats only the water you need rather than the whole tank, saving energy and giving a quick recovery. Sensor pockets are fitted.
Complete G3 kit with WRAS-approved inlet group
Expansion vessel, dual stat, PRV, inlet group, diverter valve and tundish supplied as standard, with manual-reset safety on the immersion thermostats.
Easy to install and handle
Every connection sits on a 30-degree plane at the front, and a lightweight build with a built-in carry handle makes it easier to manoeuvre.
Technical specification
Construction and pressure
Cylinder material
Grade 444 stainless steel
Insulation
50 mm Neopor EPS
Max design pressure (cylinder)
7 bar
Normal operating pressure
3 bar
Max working temperature (cylinder)
85°C
Max operating temperature (fluid)
90°C
Temperature and pressure relief valve
90°C / 7 bar
Expansion relief valve setting
6 bar
Pressure reducing valve setting
3 bar
Expansion vessel pre-charge
3 bar
Inlet group max static working pressure
12 bar
Cold and hot water connections
22 mm compression
Primary coil
Coil max design pressure
16 bar
Max primary operating pressure
3 bar
Primary flow rate (manufacturer figure)
1,400 l/h (all sizes)
Controls and electrical
Immersion heater
1 × 3 kW titanium, 240 V, 12.5 A single-phase, IP24
Dual thermostat
30–70°C control range, 82°C high-limit cut-out
Orientation and warranty
Orientation
Vertical, floor-standing on a level, frost-free surface
Tank warranty
25 years (mains supply); 5 years (private supply)
Parts and labour warranty
2 years
Size-by-size specification
Specification
150L
180L
200L
250L
300L
Product code
Part number
212960
212961
212962
212963
212964
Capacity, dimensions and weight
Rated storage water volume
142.1 L
167.3 L
199.6 L
234.2 L
283.4 L
Height (housing, excl. connections)
1192 mm
1372 mm
1594 mm
1485 mm
1750 mm
Minimum footprint diameter
550 mm
550 mm
550 mm
604 mm
604 mm
Weight empty (datasheet)
30.6 kg
36.5 kg
43.9 kg
48.6 kg
56.4 kg
Weight full
172 kg
204 kg
244 kg
282 kg
340 kg
Primary coil
Coil surface area
1.42 m²
1.92 m²
2.42 m²
2.55 m²
2.98 m²
Coil rating
28.9 kW
35.5 kW
41.5 kW
41.7 kW
40.9 kW
Coil length
16 m
21.8 m
27.5 m
29 m
33.9 m
Primary pressure drop
45 mbar
61 mbar
78 mbar
81 mbar
95 mbar
Performance
Reheat 15°C to 60°C
13 min
13 min
14 min
16 min
18 min
Standing heat loss (datasheet)
64.6 W
72.1 W
81.7 W
89.2 W
101.7 W
Heat loss (EN 12897, datasheet)
1.55 kWh/24h
1.73 kWh/24h
1.96 kWh/24h
2.14 kWh/24h
2.44 kWh/24h
ErP energy class (datasheet)
C
C
C
C
D
Immersion heater
1 × 3 kW
1 × 3 kW
1 × 3 kW
1 × 3 kW
1 × 3 kW
Frequently asked questions
Why is grade 444 stainless steel better for a hot water cylinder?
Intergas make every Xylinder tank from grade 444 stainless steel, where the industry standard is Duplex 2304. They describe it as one of the highest grades on the market, with extreme corrosion resistance to limescale, chlorine, stress and pitting and high heat transfer capability, which suits a coil-heated cylinder. The tank is backed by a 25-year warranty on mains water.
How is the Heat Pump Xylinder different from the Indirect model?
The Heat Pump model has a much larger coil, 1.42 to 2.98 m² against 0.78 m², with 28 mm connections instead of 22 mm. This brings manufacturer reheat times down to 13 to 18 minutes, against 20 to 39 minutes on the Indirect model, with a lower primary pressure drop of 45 to 95 mbar against 124 mbar.
How do I check it suits my heat pump?
Compare the cylinder's coil rating (28.9 to 41.7 kW) and primary pressure drop (45 to 95 mbar at 1,400 l/h) with your heat pump's output and circulation pump. Use 28 mm primary pipework, and keep the primary operating pressure within the coil's 3 bar limit.
What is the immersion heater for?
A 3 kW titanium immersion heater is fitted above the coil. It provides backup and boost heating, and because it sits above the coil it heats only the water needed for a quick shower rather than the whole cylinder.
Which size should I choose, and how much space is needed?
Choose by household hot water demand and available space. Note that the 250L is shorter (1485 mm) than the 200L (1594 mm) but wider (604 mm against 550 mm), which can help where ceiling height is limited. The 300L is the tallest at 1750 mm and weighs 340 kg when full, so check floor loading.
What is included, and does it need a qualified installer?
The standard Intergas G3 kit is included: expansion vessel, dual stat, PRV, inlet group, diverter valve and tundish. Yes. Unvented cylinders fall under Building Regulations Part G3, so installation, commissioning and annual servicing must be done by a competent, G3-qualified installer. Fit the tundish within 600 mm of the T&P valve with a correctly sized discharge pipe (D2), and complete the Benchmark commissioning record.
What does the warranty cover?
The tank carries a 25-year warranty on a mains water supply, reduced to 5 years on a private supply (well, spring or borehole), plus a 2-year parts and labour warranty on all components. To keep the warranty valid, register the cylinder on MiREG, have it serviced annually by a competent installer with the Benchmark service record completed, and use only original Intergas spare parts.