Protection is built in. A pressure differential switch switches the heater on only when the outlet opens, two over-temperature cut-outs guard against abnormal conditions, and a 10 bar expansion relief valve and tee piece are supplied. The vandal-resistant white ABS casing is IPX5 rated, and the heater is backed by a 2 year manufacturer guarantee.
Electrical and installation safety
Must be installed and commissioned by a competent person in line with the Water Fittings Regulations and Building Regulations G3. At 9kW the heater draws about 37.5A at 240V, so confirm the supply before ordering. It needs its own circuit, a 40A double-pole isolator (at least 3mm contact separation per pole), earthing and a 30mA RCD, and the consumer unit main switch should be 80A or above. Fit the supplied relief valve and tee piece on the outlet pipework, discharging through a tundish to a safe, visible point. Electrical work must comply with BS 7671 and Part P.
One outlet at a time, no mixer valves
The heater supplies one outlet at a time through a single outlet valve, which must be fully open to deliver the set flow and temperature. Do not use with mixer valves, and do not use in steam rooms or steam cubicles.
Not sure the supply will cope?
The 7kW sibling (95050424) uses the same casing, connections and safety devices but draws about 29A at 240V and needs only a 30A isolator. Choose the 9kW when the extra heating capacity is worth the heavier electrical demand.
Higher heating capacity
At 9kW it has more power than the 7kW model, so it can heat more water per minute to the same temperature, or reach a higher temperature at the same flow.
Instant hot water, no cylinder
Heats mains water as it flows to a single shower or tap. There is no storage tank to fill and no standing heat loss.
Compact footprint
Only 160mm wide and 104mm deep on the wall, and the manufacturer notes it can be concealed from view in many installations.
Vandal-resistant casing
White moulded ABS casing built to cope with shared, remote and public-facing locations, with an IPX5 enclosure rating.
Two-stage over-temperature safety
Two over-temperature cut-outs, including a one-shot cut-out, with the safety cut-out pre-set at 88°C (190°F). A pressure differential switch only starts the heater when water is flowing.
Safety kit included
The 10 bar expansion relief valve, tee piece, fixing screws, wall plugs and fitting instructions are all supplied.
General
Range
Multipoint Instantaneous
Model
Multipoint Instantaneous 9kW
Manufacturer part code
95050425 (95:050:425)
Product type
Instantaneous point-of-use electric water heater, closed-outlet unvented
Colour / finish
White, moulded ABS
Energy label (ErP)
Class A, load profile XXS
Electrical
Rated output
9kW at 240V (8.2kW at 230V)
Maximum current draw (calculated)
Approximately 37.5A at 240V (calculated from rated output)
Supply
230/240V AC only, on its own independent circuit
Double-pole isolating switch
40A, contacts at least 3mm apart per pole
Consumer unit main switch
80A or above
Earth and RCD
Must be earthed; 30mA RCD required in the circuit
Cable entry
Bottom or rear
Water and connections
Operating pressure
Minimum 1 bar (0.1 MPa), maximum 7 bar (0.7 MPa)
Inlet / outlet connections
½" BSP male, suitable for 15mm copper pipe
Outlets
One outlet at a time, controlled by a single outlet valve. Not for use with mixer valves
Expansion relief valve
10 bar (1 MPa), supplied; fitted with the supplied tee piece on the outlet pipework
Relief valve discharge
Via a tundish to waste in a safe, visible location; 22mm bore discharge pipe falling continuously, protected from frost
Construction, controls and safety
Casing
White moulded vandal-resistant ABS; ABS backplate and cover
Inner container
Glass-reinforced nylon, with drain plug to drain the container and prevent freezing
Element
Copper-sheathed rod type
Flow control
Pressure differential switch, automatic operation when the outlet opens; neon power indicator
Temperature setting
No user thermostat; set at commissioning with the isolating ball valve (flow restrictor). Manufacturer advises 48°C should not normally be exceeded
Over-temperature protection
Two over-temperature cut-outs (one-shot and a second cut-out); safety cut-out pre-set at 88°C (190°F)
Dimensions
Width x depth
160mm x 104mm
Height
240mm in the brochure dimension drawing; 210mm in the fitting instructions (see note above)
Approvals and guarantee
Approvals
BEAB approved, Kiwa approved, CE marked; EN 60335-2-35
Regulations
Water Fittings Regulations and Building Regulations G3 (England and Wales)
Manufacturer guarantee
2 years, transferable. Frost damage and scale build-up are excluded
In the box
Heater, fixing screws and wall plugs, 10 bar (1 MPa) expansion relief valve, tee piece, fitting instructions
Not in the box
Isolating ball valve (flow restrictor), isolating stop valve, tundish, double-pole isolator
Will my electrical supply cope with a 9kW heater?
The 9kW needs its own 230/240V circuit, a 40A double-pole isolating switch (at least 3mm contact separation per pole), earthing and a 30mA RCD. The calculated current draw is about 37.5A at 240V, and the consumer unit main switch should be 80A or above. A qualified electrician must select the cable and protective device to BS 7671. If spare capacity is limited, the 7kW model is the lighter option.
Is the 9kW physically larger than the 7kW?
No. Both models share the same 160mm width and 104mm depth, the same casing and the same ½" BSP connections. The manufacturer's brochure applies one set of dimensions to all models.
Can it supply more than one tap or shower at once?
No. It supplies one outlet at a time through a single outlet valve and must not be used with mixer valves, whatever the power rating.
How is the outlet temperature set?
There is no user thermostat. The temperature is set at commissioning using the isolating ball valve (flow restrictor), and the outlet valve must then be fully open. The manufacturer advises that 48°C should not normally be exceeded.
What are the water pressure and pipework requirements?
Supply pressure must be between 1 bar and 7 bar. Connections are ½" BSP male inlet and outlet for 15mm copper pipe, with water entering at the bottom. The relief valve must discharge through a tundish to a safe, visible location via a continuously falling 22mm bore pipe; the tundish is not in the box.
What does the 2 year guarantee involve?
The 2 year manufacturer guarantee applies when the heater is installed to the instructions and regulations, with approved valves and controls, and used with potable water only. Frost damage and scale build-up are excluded, and the heater should not be switched on if the water may be frozen.