The Fox ESS T20-G3 is a 20kW three-phase string inverter from the T Series (G3) range, designed for three-phase residential and small-scale commercial solar installations. With two independent MPP trackers, 2+2 string inputs and up to 30kW of PV input, it gives installers generous array flexibility on larger roofs and split-orientation sites.
A wide 140V to 1000V MPPT range and a low 140V start-up voltage extend the generating day, while a 98.6% maximum efficiency keeps conversion losses low. Built to an IP65 rating for outdoor mounting, it supports remote monitoring through the FoxCloud 2.0 app and web portal.
Grid Connection: G99 Application Required
A 20kW three-phase output is above the 16A-per-phase G98 limit, so a G99 application to the Distribution Network Operator must be approved before installation and commissioning. Installation must be carried out by a competent person in line with BS 7671 and the manufacturer's installation manual.
DC Isolation and AFCI Are Listed as Options
The manufacturer lists the integrated DC switch and AFCI as optional features. Where the unit does not include an integrated DC switch, an external DC isolator must be fitted in the PV circuit. Confirm the specification you need at order stage.
Dual MPPT, Four String Inputs
Two MPP trackers each take two strings (2+2), with 28A maximum input current and 36.4A short-circuit current per tracker. Mixed roof pitches and orientations can be matched to separate trackers.
Wide Voltage Window
A 140V to 1000V MPPT operating range and 140V start-up voltage let the inverter begin generating earlier in the morning and keep going later into the evening.
High Efficiency
98.6% maximum efficiency, 97.8% European efficiency and 99.8% MPPT efficiency turn more of every kilowatt-hour of sunlight into usable energy.
Built for Outdoor Mounting
An IP65 enclosure and an operating range of -25°C to +60°C (derating from +45°C) suit exposed wall locations, in a compact transformerless design.
Grid Support and Safety Interfaces
Adjustable power factor from 0.8 leading to 0.8 lagging, THDi below 3%, plus DRM, emergency-stop and smart-meter interfaces on board.
Simple Commissioning
Plug-and-play wall mounting, an LCD with touch key, a status LED (blue normal, red fault) and a USB port for firmware upgrades keep site work straightforward.
DC Input (PV)
Max. PV input power
30,000 W
Max. DC input voltage
1100 V
Rated input voltage
600 V
MPPT operating voltage range
140 to 1000 V
Start-up input voltage
140 V
Strings per MPP tracker
2+2
Max. input current (per MPPT)
28 A
Max. short-circuit current (per MPPT)
36.4 A
AC Output
Rated output power
20,000 W
Max. apparent output power
22,000 VA
Rated grid voltage
3/N/PE, 220/380, 230/400, 240/415 V
Rated grid frequency
50 / 60 Hz
Max. output current
31.9 A
Power factor
1 (adjustable 0.8 leading to 0.8 lagging)
Efficiency
European efficiency
97.8%
Night-time self-consumption
<3 W
Protection
Insulation resistance monitoring
Yes
Residual current monitoring
Yes
DC reverse polarity protection
Yes
Anti-islanding protection
Yes
AC short-circuit, overcurrent and overvoltage protection
Yes
Surge protection (DC / AC)
Type II / Type II
General Data
Dimensions (mm)
370 x 480 x 183.5
Operating temperature
-25°C to +60°C (derating from +45°C)
Humidity
0 to 100%, non-condensing
Max. operating altitude
3000 m
Installation clearances
300 mm each side; 500 mm above, below and in front
Communication and Display
Interfaces
RS485, smart meter, DRM, E-stop, USB
Wireless monitoring
WiFi / 4G (optional module)
Display
LCD with touch key
Monitoring platform
FoxCloud 2.0 (app and web portal)
Certifications and Standards
Grid codes
G98, G99, EN 50549-1, VDE-AR-N 4105, C10/11, RD 1699, CEI 0-21 and others
Does the T20-G3 need a G99 application?
Yes. At 20kW three-phase the output exceeds the 16A-per-phase G98 limit, so the installer must obtain G99 approval from the DNO before the system is installed and commissioned.
How many solar strings and how much PV can I connect?
The inverter has 2 MPP trackers with 2+2 string inputs (four strings in total) and a 30kW maximum PV input, which is 150% of the 20kW AC rating. Each tracker accepts up to 28A input current.
Can I connect a battery to the T20-G3?
No. This is a PV-only on-grid string inverter with no battery port. For storage or backup power, choose a three-phase hybrid inverter.
Is a DC isolator built in?
The manufacturer lists the DC switch as optional. If the unit you receive has no integrated DC switch, fit an external DC isolator in the PV circuit.
Is it suitable for outdoor installation?
Yes. It is rated IP65 with an operating range of -25°C to +60°C, derating from +45°C. Leave 300 mm clearance each side and 500 mm above, below and in front, and mount on a wall within 5° of vertical.
How do I monitor the inverter?
Through FoxCloud 2.0 on a smartphone app or web portal. A WiFi or 4G module is available as an option, and an RS485 smart-meter port is built in.