The EPH Controls CP4i is a WiFi-enabled OpenTherm® smart thermostat pack for installers who want app control without a complicated commissioning job. The box contains an RFRP-OT programmable wireless room thermostat, an RF1A-OT wireless boiler receiver and a GW03 dual-band 2.4/5GHz gateway, all pre-paired at the factory. Once the receiver is wired to the boiler, the system is ready to connect to the EMBER app on iOS and Android.
Because the receiver passes OpenTherm® modulation data to a compatible boiler, the thermostat can vary the boiler's flow temperature to suit actual heat demand instead of simply switching it on and off. Optimum Start and TPI control modes are built in, the thermostat offers six time and temperature periods per day, and the system expands to up to six zones by adding thermostats. Hot water control is available with the separate CP4-HW-OT cylinder thermostat, and the EMBER app adds Alexa voice control, multiple users and multiple homes.
2.4/5GHz
Dual-band gateway
OpenTherm®
Boiler modulation
5 Years
Manufacturer warranty
What's in the box
1 × RFRP-OT wireless programmable thermostat, 1 × RF1A-OT wireless receiver, 1 × GW03 dual-band gateway with power supply and instructions. The thermostat runs on 2 × AA alkaline batteries; EPH recommends good-quality branded cells.
Compatibility notes
Modulation needs an OpenTherm®-compatible boiler wired to the receiver's OpenTherm® terminals. For on/off boilers the RF1A-OT provides a volt-free SPDT output for mains or low-voltage switching. Set the system up in the EMBER app as a Thermostat System (TS). Hot water control needs the additional CP4-HW-OT thermostat.
Installation safety
Installation and connection must be carried out by a competent person in accordance with BS 7671. Never connect mains voltage to the OpenTherm® terminals. Isolate the supply before opening the receiver.
Key Features
Pre-paired for fast installs
The thermostat, receiver and gateway are paired in production, so there is no RF pairing to carry out on a standard single-zone job.
OpenTherm® modulation
Adjusts the boiler's flow temperature to match demand. Installer-adjustable heating setpoint limits, weather-compensation climatic curve for boilers with an outside sensor, and room sensor influence settings.
Optimum Start and TPI
Optimum Start works out when to fire up so the room reaches temperature on time, with up to 3 hours pre-heat. TPI cycles the heating to avoid overshoot, with 2, 3, 6 or 12 cycles per hour.
Flexible programming
Six periods per day in 5/2 day, 7 day or 24 hour modes, a copy function, temporary and permanent override, boost for 30 minutes, 1, 2 or 3 hours, and a holiday mode.
EMBER app and voice control
Control heating from anywhere with the EMBER app, invite multiple users, manage multiple homes and use Alexa voice control to boost zones and check temperatures.
Expandable to six zones
Add further thermostats to reach up to six zones on one OpenTherm® boiler using a hub receiver. A keypad lock, PIN lock and calibration option are also built in.
Technical Specification
Pack Contents
Gateway
GW03 dual band 2.4/5GHz × 1
RFRP-OT Thermostat
Power supply
2 × AA alkaline batteries (replace approximately once a year)
Temperature control range
5…35°C
Ambient temperature
0…45°C
Dimensions
130 × 99 × 25 mm
Temperature sensor
NTC 100K Ω @ 25°C
Switching differential
Default 0.4°C, adjustable 0…1.0°C
Frost protection
5°C default, adjustable 5…15°C
Programming
6 periods per day; 5/2 day, 7 day or 24 hour modes
Control modes
OpenTherm®, Optimum Start, TPI, On/Off
Mounting
Wall mounted or free standing (stand included)
RF1A-OT Receiver
Power supply
200–240Vac, 50–60Hz
Contact rating
230Vac 10(3)A
Switch output
SPDT volt free
Ambient temperature
0…45°C
Appliance class
Class II; pollution degree 2; IP20
Rated impulse voltage
2500V as per EN 60730
Wireless range
Mount within 20 metres of the thermostat, more than 1 metre from metal objects and electronic devices
GW03 Gateway
Wi-Fi
Dual band 2.4GHz and 5GHz (SSID must not be hidden during pairing)
App
EMBER Smart Heating (iOS and Android)
Thermostats per gateway
Up to 6
Status LEDs
Red: power; green: Wi-Fi connected; white: connected to receiver
OpenTherm® Installer Parameters
Max / min heating setpoint
Max 45–85°C (default 85°C); min 10°C up to the max setting (default 45°C)
Climatic curve (weather compensation)
0.2–3.0 (default 1.2); outside sensor required on the boiler
Room sensor influence on modulation
0–20 (default and recommended value 10)
Approvals and Warranty
Frequently Asked Questions
What is included in the CP4i pack?
The pack contains the RFRP-OT thermostat, the RF1A-OT receiver and the GW03 gateway, supplied with the gateway power supply and instructions. The three parts are pre-paired, so no RF pairing is needed on a standard install.
Does the CP4i work with my boiler?
With an OpenTherm®-compatible boiler, run a dedicated two-core cable from the receiver's OpenTherm® terminals to the boiler to enable modulation. For boilers without OpenTherm®, the receiver's volt-free SPDT contact switches the boiler on and off by mains or low-voltage wiring. Check your boiler manufacturer's documentation to confirm OpenTherm® support.
How many zones can I control?
Up to six. Add further RFRP-OT thermostats, make one receiver the hub (connected to the boiler by OpenTherm®) and pair the remaining receivers to it. A maximum of 6 thermostats can be used with each GW03 gateway. Hot water control is available with the CP4-HW-OT cylinder thermostat.
Does it meet Boiler Plus requirements?
The CP4i combines OpenTherm® modulation with Optimum Start, the features EPH points to for Boiler Plus. The installer remains responsible for confirming that the complete installation meets the Boiler Plus requirements for the boiler being fitted.
What Wi-Fi do I need for the gateway?
The GW03 supports 2.4GHz and 5GHz routers. Fit it near the receiver where Wi-Fi is strong and keep it clear of microwaves, televisions, Wi-Fi boosters and smart speakers. Do not hide the router's SSID during pairing.
Will the heating still work if the internet goes down?
Yes. The link between thermostat and receiver is local RF; the gateway only adds EMBER app control. The thermostat can be programmed and operated from its own keypad at any time.