What's in the box
1 × RFRP-TW programmable RF Touch Thermostat (with 4 × AAA batteries), 1 × RF1B wireless receiver and 1 × GW04-v2 dual-band gateway, supplied pre-paired.
Compatibility notes
The floor and external air sensor modes need an NTC10K plug sensor, sold separately; the same plug is needed for the cylinder (CYL) range. In the EMBER app, select the black GW04 gateway when prompted. In multi-zone systems there can be only one hub receiver, and receivers must be fitted at least 25cm apart or they will not pair.
Touch Thermostat
A sleek new Touch Thermostat with a white backlight, 91 × 91 × 23 mm body, wall or table mounting (stand included) and a PIN lock.
OpenTherm® modulation
Adjusts the boiler's flow temperature to demand. Installer settings include heating setpoint limits, climatic curve for weather compensation and room sensor influence.
Three sensor modes
Choose the internal air sensor, an external air sensor for an adjacent room, or the internal sensor with an external floor high-limit sensor (default limit 26°C, adjustable 5–45°C).
Optimum Start and TPI
Optimum Start reaches the target temperature by the program start time, with up to 3 hours of pre-heat. TPI cycles the heating to avoid overshoot.
Dual-band Wi-Fi or Ethernet
The GW04-v2 gateway connects by 2.4/5GHz Wi-Fi or LAN cable to the EMBER app, with multiple user invitations and zone grouping.
Expandable and flexible
Add up to six RFRP-TW thermostats with RF1B receivers. A CYL mode covers 5…90°C for cylinder thermostat use, and a holiday mode switches heating off for set periods.
Pack Contents
Gateway
GW04-v2 dual band
RFRP-TW Thermostat
Power supply
4 × AAA alkaline batteries (supplied)
Power consumption
Less than 1W
Temperature range
Heating 5…35°C; cylinder (CYL) hot water 5…90°C
Ambient temperature
0…45°C; humidity 5–95% RH
Dimensions
91 × 91 × 23 mm
Internal temperature sensor
NTC 100K
Hysteresis (switching differential)
Heating 0…1°C in 0.1°C steps (default 0.4°C); CYL 0…20°C in 0.5°C steps
Frost protection
5°C default, adjustable 5…15°C (active in OFF and Holiday modes)
Programming
6 periods per day; 5/2 day, 7 day or 24 hour modes
Operating modes
Normal, Optimum Start, TPI
Floor high limit (FHL)
26°C default, adjustable 5…45°C
Mounting
Wall mounted or table mounted (stand included)
Protection rating
IP20; pollution degree 2
RF1B Receiver
Power supply
200–240Vac, 50–60Hz
Switch output
SPDT volt free; mains or low-voltage switching
Ambient temperature
0…45°C
Appliance class
Class II; pollution degree 2; IP20
Rated impulse voltage
2500V as per EN 60730
Wireless range
Mount within 20 metres of the thermostat
Multi-zone
One hub receiver plus branch receivers; up to 6 RF1B receivers
Indicators
System, Hub, RF and OpenTherm® LEDs
GW04-v2 Gateway
Connectivity
Dual band 2.4/5GHz Wi-Fi or Ethernet (LAN)
App
EMBER Smart Heating; iOS 11.0 or later, Android 5.1 or later
Zones per gateway
Up to 6 receivers connect to the hub
Status LEDs
Power, Wi-Fi, LAN and RF
OpenTherm® Installer Parameters
Max / min heating setpoint
Max 45–85°C (default 85°C); min 10°C up to the max setting (default 45°C)
Climatic curve (weather compensation)
0.2–3.0 (default 1.2); outside sensor required on the boiler
Room sensor influence on modulation
0–20 (default and recommended value 10)
Approvals and Warranty
What is included in the CP5i pack?
The pack includes the RFRP-TW thermostat with its 4 × AAA batteries, the RF1B receiver and the GW04-v2 gateway. The three parts are pre-paired, so there is no RF pairing step on a standard install.
Does the CP5i work with a non-OpenTherm® boiler?
Yes. The RF1B has a volt-free SPDT output. For mains switching, link L to terminal 1; for low-voltage switching, remove the external controls link on the boiler PCB and connect to the RF1B terminals. OpenTherm® modulation needs a compatible boiler and a dedicated two-core cable.
How do I add more zones?
Add further RFRP-TW thermostats (sold individually) with an RF1B receiver for each zone. Make one RF1B the hub by holding Manual and Connect for 5 seconds, then pair the others as branch receivers. The system supports up to 6 thermostats, and receivers must be at least 25cm apart.
Can I use a floor sensor?
Yes. Set AFS mode 03 to use the internal air sensor with an external floor high-limit sensor; the limit defaults to 26°C and can be set from 5 to 45°C. An NTC10K plug sensor is required and sold separately.
Should I use Wi-Fi or the LAN port?
The GW04-v2 supports both. EPH recommends Wi-Fi for the best range. If you use the LAN cable, leave 1–2 metres between the router and the gateway to limit RF interference.
Why does the display show a battery warning?
The battery low symbol appears on the thermostat and in the EMBER app when the 4 × AAA cells are nearly empty. Replace them straight away with Duracell or Energizer type batteries; poor-quality cells can interrupt wireless communication or reset the thermostat.