The EPH Controls CP4V2 is the latest version of the popular CP4 OpenTherm® programmable wireless room thermostat and receiver pack. It adds a redesigned RF1B receiver that fits an industry-standard 6 pin backplate and a new 30 minute boost option, while keeping the proven Optimum Start, TPI, On/Off and OpenTherm® modulation control modes. The RFRPV2 thermostat and RF1B receiver are pre-paired, so there is no pairing step on a standard install.
The thermostat offers six time and temperature periods per day, boost for 30 minutes, 1, 2 or 3 hours, a holiday mode, a backlit LCD, temperature calibration and a PIN lock with two lock levels. An optional service interval reminder can be enabled through EPH customer service. For multi-zone jobs, up to six CP4V2 thermostats can control one OpenTherm® boiler through a hub receiver, and adding a GW04 gateway (sold separately) brings EMBER app control.
30 min
Shortest boost option
6 pin
Standard backplate receiver
6
Zones on one OpenTherm® boiler
What's in the pack
1 × RFRPV2 wireless programmable thermostat and 1 × RF1B wireless receiver, supplied pre-paired. The thermostat is powered by 2 × AA alkaline batteries, and EPH recommends Duracell or Energizer cells.
Smart upgrade is sold separately
The CP4V2 does not include a Wi-Fi gateway. To control it from the EMBER app, add a GW04 gateway, make the RF1B a hub receiver and pair the two.
Receiver contact rating
EPH's current RF1B datasheet and CP4V2 product page list the receiver contact rating as 230Vac, 3A, while the earlier CP4V2 installation guide shows 250Vac 10(3)A. Until you have confirmed the rating with EPH, keep the switched load within 3A and use a relay or contactor for anything higher.
Installation safety
Installation and connection must be carried out by a qualified person in accordance with BS 7671. Only qualified electricians or authorised service staff should open the thermostat. Connect an OpenTherm® boiler with a dedicated two-core cable from the RF1B OpenTherm® terminals.
Key Features
30 minute boost
Boost to a chosen temperature for 30 minutes, 1, 2 or 3 hours in any mode except holiday, using one press of the BOOST button.
6 pin backplate receiver
The redesigned RF1B fits an industry-standard 6 pin backplate, making replacement and first-fix installs simpler.
OpenTherm® modulation
Adjusts the boiler's flow temperature to demand. Installer-adjustable setpoint limits, climatic curve and room sensor influence.
Optimum Start and TPI
Optimum Start pre-heats up to 3 hours so the room is warm on time; TPI cycles heating 2, 3, 6 or 12 times per hour to avoid overshoot.
Flexible programming
Six periods per day in 5/2 day, 7 day or 24 hour modes, plus a copy function, temporary and permanent override and a holiday mode.
Scalable to six zones
Add thermostats and receivers for up to six zones with a hub and branch receiver arrangement, or add a GW04 gateway for EMBER app control.
Technical Specification
Pack Contents
RFRPV2 Thermostat
Power supply
2 × AA alkaline batteries (replace approximately once a year)
Temperature control range
5…35°C
Ambient temperature
0…45°C
Dimensions
130 × 95 × 23 mm
Temperature sensor
NTC 100K Ω @ 25°C
Switching differential
0.4°C default; HOn 0.2…1.0°C, HOFF 0.0…1.0°C
Frost protection
5°C default, adjustable 5…15°C (active in OFF and Holiday modes)
Programming
6 periods per day; 5/2 day, 7 day or 24 hour modes
Control modes
OpenTherm®, Optimum Start, TPI, Normal (On/Off)
Boost
30 minutes, 1, 2 or 3 hours
PIN lock
Two options: full lock, or reduced functionality (AUTO / OFF only)
Mounting
Wall mounted or free standing (stand included)
RF1B Receiver
Power supply
200–240Vac, 50–60Hz
Contact rating
230Vac 3A (see compatibility note above)
Switch output
SPDT volt free; mains or low-voltage switching
Ambient temperature
0…45°C
Appliance class
Class II; pollution degree 2; IP20
Rated impulse voltage
2500V as per EN 60730
Wireless range
Mount within 20 metres of the thermostat, with over 25cm clearance from metal objects
Backplate
Industry standard 6 pin
Multi-zone
One hub receiver plus branch receivers; up to 6 receivers
OpenTherm® Installer Parameters
Max / min heating setpoint
Max 45–85°C (default 85°C); min 10°C up to the max setting (default 45°C)
Climatic curve (weather compensation)
0.2–3.0 (default 1.2); outside sensor required on the boiler
Room sensor influence on modulation
0–20 (default and recommended value 10)
Frequently Asked Questions
What is new compared with the original CP4?
EPH redesigned the receiver to fit an industry-standard 6 pin backplate and added a 30 minute boost option. The control modes (OpenTherm®, Optimum Start, TPI and On/Off) carry over.
How does the boost function work?
Press BOOST once for 30 minutes, twice for 1 hour, three times for 2 hours or four times for 3 hours, then adjust the boost temperature if needed. BOOST TO and the end time show on the display. Press BOOST again to cancel.
Does the CP4V2 work with boilers that do not support OpenTherm®?
Yes. The RF1B has a volt-free SPDT output for mains or low-voltage switching. For OpenTherm® modulation, connect a compatible boiler with a dedicated two-core cable from the RF1B.
How many CP4V2 thermostats can control one boiler?
Up to six. Make one RF1B a hub by holding Manual and Connect for 5 seconds, then pair the other receivers as branch receivers. Fit receivers at least 25cm apart and allow 2 to 5 minutes for them to start sharing OpenTherm® data.
Can I control it from my phone?
Yes, with an optional GW04 gateway (sold separately) and the EMBER app. The RF1B must be set as a hub receiver before pairing it to the gateway.
Where should I fit the thermostat and receiver?
Mount the thermostat 1.5 metres above floor level, away from sunlight and other heat or cooling sources. Fit the receiver within 20 metres of the thermostat, over 25cm from metal objects and at least 1 metre from electronic devices such as routers and microwaves.