The EPH Controls B322MID is a 22mm compression 3 port motorised mid-position valve for domestic heating systems that have both a hot water cylinder and a central heating circuit. In mid-position operation, a call for heating alone opens Port A, a call for hot water alone opens Port B, and a call for both brings the valve to the mid position with Port A and Port B open, delivering a 7.1 Kvs flow rate through the valve.
The 230V actuator uses a spring return that closes Port A and opens Port B if mains power is lost, and a manual override lever allows the system to be filled, flushed or drained. The valve is rated for a maximum operating pressure of 21 bar and a permanent operating temperature of 2…88°C. It is supplied with a 1.2 metre, 5 core cable, has a removable actuator head and can also be wired as a diverter valve.
22mm
Compression connections
88°C
Max. fluid temperature
21 bar
Max. operating pressure
1.2m
5 core cable supplied
Valve position by wiring
No supply or 230V to orange or grey: hot water, Port B open. 230V to white: mid position, Port A and Port B open. 230V to grey and white together: central heating, Port A open. Without power the valve spring returns to Port A closed and Port B open.
Fitting notes
Fit the valve so the actuator head is not below the horizontal level of the pipework, with flow in the direction of the arrow, from the centre port to Port A or Port B. The open vent and cold feed must not be isolated. Use the valve body only for grip when tightening the compression nuts, and do not overtighten.
Installation safety
Installation must be carried out by a qualified person in accordance with wiring regulations. Fuse the system to no more than 3A. Use 230V only, an earth connection is required, and never insulate or cover the actuator because it must not exceed its 50°C maximum ambient temperature. This is not a fail-safe, no-fail or safety product.
Key Features
Mid-position operation
Serves central heating and hot water circuits together, with Port A and Port B open when both call for heat.
High flow rate
7.1 Kvs through the 22mm body, with maximum close-off pressures of 1.6 bar (Port A) and 1.2 bar (Port B).
Spring return actuator
230V, 5W impedance-protected motor; on power loss the valve returns to Port A closed, Port B open.
Manual override
A manual lever opens the valve for filling, flushing or draining; return it to Auto for normal operation.
Ready to wire
Supplied with a 1.2 metre, 5 core cable (blue, orange, grey, white, yellow/green) and nuts and olives for the compression joints.
Diverter wiring option
With grey and white cores linked, the valve works as a diverter: 0V opens Port B (hot water), 230V opens Port A (heating).
Technical Specification
Valve
Connection
22mm compression
Ports
3 (centre port to Port A or Port B)
Function
Mid position; can be wired as a diverter
Max. close-off pressure
1.6 bar (Port A); 1.2 bar (Port B)
Max. static / operating pressure
21 bar
Permanent operating temperature
2…88°C
Actuator
Motor supply voltage
230V
Max. ambient temperature
50°C
Movement
Rotary, multi position; spring return
Classification
Type 1.AA in accordance with EN 60730
Rated impulse voltage
2500V
Lead
1.2 metre, 5 core cable; earth connection required
Spindle
4mm flat; actuator head removable from the valve body
Wiring Colours (Mid Position)
Orange
Hot water ON from cylinder thermostat or programmer; also connect to boiler and pump live
Grey
Hot water OFF from cylinder thermostat or programmer
White
Central heating ON from room thermostat or programmer
Frequently Asked Questions
How does a mid-position valve work?
A call for heating only opens Port A; a call for hot water only opens Port B; both calls together bring the valve to the mid position with Port A and Port B open. The boiler and pump live is taken from the orange core.
What happens if the power fails?
The actuator spring returns to Port A closed and Port B open. EPH states this is not a fail-safe, no-fail or safety product, so it should not be relied on for safety functions.
How should I position the valve?
Mount it so the actuator head is not below the horizontal level of the pipework, with flow in the direction of the arrow from the centre port to Port A or Port B. Do not isolate the open vent or cold feed.
How do I fill, flush or drain the system?
Move the manual override lever to the raised manual position to hold the valve open, flush and drain as required, then refill and add inhibitor if needed. Return the lever to Auto before commissioning.
Can I use it as a diverter valve?
Yes. Connect the grey and white cores together to the heating switch: 0V opens Port B (hot water, normally open) and 230V opens Port A (heating). Terminate the orange core safe, as it carries 230V when grey and white are also live.
Is the actuator replaceable?
The actuator can be removed from the valve body by setting the lever to manual, loosening the side screw and the two base screws. It refits to the 4mm flat spindle, so the valve body can stay in the pipework.