The Dyness LS Series 6.0kW LV Hybrid Inverter (D6.0K-LS) is a single-phase, 48V low-voltage hybrid inverter that manages solar, battery storage, grid and backup supply from one wall-mounted, IP66-rated unit. It delivers 6,000VA nominal grid output (6,600VA maximum), accepts up to 12,000W of PV across two MPP trackers with 20A inputs, and charges or discharges a 48V battery at up to 140A (6,000W charge / 6,600W discharge).
If the grid fails, the backup port takes over in under 4ms, supplying 6,600VA continuously and up to 12,000VA for 10 seconds (200% overload) to ride through motor and compressor start-up surges. A generator port with load control, AI Correct CT direction fix, colour touch LCD and parallel operation of up to 16 units make it a flexible fit for UK homes and small commercial sites. Natural-convection cooling keeps noise below 30dB, and a 97.6% maximum efficiency (96.5% Euro) keeps conversion losses low.
Qualified Installation and DNO Approval Required
Installation and commissioning must be carried out by a competent person in accordance with BS 7671 and Part P where applicable. Connection requires DNO notification (G98) or prior approval (G99) depending on export capacity. The BACK-UP port is live whenever the inverter is on: isolate the inverter and wait 5 minutes after power-off before working on it or on backed-up circuits. Never connect a PV string or a battery to more than one inverter.
48V Low-Voltage Batteries Only – Battery Not Included
The D6.0K-LS works with 48V low-voltage batteries (lead-acid or lithium-ion, 40–60V operating range). It is not compatible with high-voltage battery stacks. No battery is supplied with the inverter, so confirm your chosen battery against the manufacturer's inverter matching list before ordering.
Backup Peak and Grid Output Limits
The 12,000VA backup peak is a 10-second surge rating available only when PV and battery power are sufficient; continuous backup output is 6,600VA. Maximum power output to grid (6,600VA) is subject to local grid regulation.
Dyness Battery Pairing
Manufacturer-listed Dyness batteries for the LS Series are the DL5.0X, DL5.0C, Powerbox Pro and Powerbrick. BMS communication is over CAN with automatic plug-and-play detection, so no manual protocol setup is normally needed.
Key Features
Seamless <4ms Backup Switching
Automatic changeover to the backup port in under 4ms keeps lights, networking and electronics running through a grid failure. Backup output is 6,600VA continuous with a 200% peak of 12,000VA for 10 seconds for start-up surges.
2:1 DC Oversizing, 110% AC Overload
Connect up to 12,000W of PV to the 6kW inverter (DC/AC ratio up to 2×) with 110% continuous AC overloading (6,600VA), helping capture more generation on east/west roofs and in low light.
20A PV Inputs for 182/210mm Panels
Two MPP trackers, each with 20A max input current (27A short-circuit) and one string per tracker, suit high-power 182mm and 210mm modules. 50–550V working range, 180–500V MPPT range at nominal power, 600V maximum.
Touch LCD and AI Correct CT
A colour touch LCD gives easy configuration and live power-flow viewing, with LED indicators and app control. AI Correct fixes the CT clamp direction automatically, avoiding rework if it is fitted the wrong way round.
Generator and Load Control Port
A dedicated AC input accepts a generator (6,000VA nominal, 12,000VA max, 50A) with dry contacts for load control. Supports Generator, Smart Load and Micro-grid modes, and generator charging of the battery.
Up to 16 Units in Parallel
Scale capacity with up to 16 inverters in parallel for both on-grid and off-grid operation. Only the master unit connects to the battery BMS and CT, and multiple batteries in parallel are supported.
Technical Specifications
Product
Manufacturer Model
D6.0K-LS
Type
Single-phase LV hybrid inverter
Battery Input
Battery Type
Lead-acid / Li-ion
Battery Voltage Range
40–60V
Nominal Battery Voltage
48V
Max Charge / Discharge Current
140A
Max Charge / Discharge Power
6,000W / 6,600W
PV String Input
Max PV Input Power
12,000W
Max PV Input Voltage
600V
Working Voltage Range
50–550V
First Feed-in Voltage
60V
MPPT Range for Nominal Power
180–500V
Nominal PV Input Voltage
380V
Max Input Current
20A / 20A
Max Short-Circuit Current
27A / 27A
Strings per MPP Tracker
1
AC Output (On-Grid Port)
Nominal Power Output to Grid
6,000VA
Max Power Output to Grid
6,600VA (subject to local grid regulation)
Max Power from Grid
12,000VA
Nominal Output Voltage
220 / 230 / 240V, L/N/PE
Nominal Output Frequency
50 / 60Hz
Nominal AC Current to Grid
27.3 / 26.1 / 25A (at 220 / 230 / 240V)
Max AC Current to Grid
30A
Max AC Current from Grid
50A
Output Power Factor
Adjustable from 0.8 leading to 0.8 lagging
Output THDi (Nominal Power)
<3%
AC Output (Back-Up Port)
Max Continuous Output Power
6,600VA
Peak Output Power
12,000VA for 10s (only if PV and battery power are sufficient)
Nominal Output Voltage
220 / 230 / 240V, L/N/PE
Nominal Output Frequency
50 / 60Hz
Output THDv (Linear Load)
<3%
AC Input (Generator Port / Load Control Port)
Nominal Input Apparent Power
6,000VA
Max Input Apparent Power
12,000VA
Nominal Input Voltage
220 / 230 / 240V, L/N/PE
Nominal AC Generator Frequency
50 / 60Hz
Efficiency
Protection
Anti-Islanding Protection
Integrated
PV Insulation Resistance Detection
Integrated
PV Reverse Protection
Integrated
Residual Current Monitoring Unit
Integrated
AC Over-Current / Over-Voltage Protection
Integrated
DC Switch (PV)
Integrated
Surge Protection
DC Type III / AC Type III
Communication Interface
Remote Shut Down
Yes (DI)
Display / User Interface
LED / LCD / App
General Data
Operating Temperature Range
-30 to 60°C
Operating Altitude
≤3,000m
Cooling
Natural convection
Size (W × H × D)
501 × 586 × 193mm
Installation
Wall-mounted
Certifications and Standards
Grid Regulation
EN 50549, NRS 097, G98, G99, IEC 61727, IEC 62116
Safety Regulation
IEC/EN 62109-1 & 2
EMC
IEC/EN 61000-6-1/2/3/4
Frequently Asked Questions
Is the Dyness D6.0K-LS compatible with high-voltage batteries?
No. It is a 48V low-voltage hybrid inverter that works with lead-acid or lithium-ion batteries in the 40–60V range. The manufacturer lists the Dyness DL5.0X, DL5.0C, Powerbox Pro and Powerbrick low-voltage lithium batteries for the LS Series, communicating over CAN. Check any other battery against the manufacturer's inverter matching list first.
How much solar can I connect?
Up to 12,000W of PV in total, split across two MPP trackers with one string per tracker. Each input accepts up to 20A (27A short-circuit), with a 600V maximum input voltage, a 50–550V working range and a 180–500V MPPT range at nominal power. The 20A inputs are designed for high-power 182mm and 210mm panels.
What happens during a power cut?
The inverter switches to its backup port in under 4ms. Backup output is 6,600VA continuous, with a peak of 12,000VA for 10 seconds when PV and battery power are sufficient. Connect only essential circuits to the backup port, and remember it is live whenever the inverter is on.
Can I connect a generator or use load control?
Yes. The generator/load control port accepts a generator rated up to 6,000VA nominal (12,000VA max, 50A) at 220/230/240V, 50/60Hz. Operating modes include Generator, Smart Load and Micro-grid, and the dry contacts are rated for a maximum of 24Vdc, 1A. A generator can also be used to charge the battery.
Can I add more inverters later?
Yes. The LS Series supports up to 16 units in parallel for both on-grid and off-grid operation. Parallel units are linked with standard network cables, the Parallel RES switch is set to ON on the first and last units only, and only the master connects to the battery BMS and CT.
What do I need to know before installing?
The unit weighs 17kg and mounts on a solid wall using the supplied backing plate, with at least 300mm clearance on all sides and no more than 5° backward tilt. A CT is included in the accessory package; for CT cable runs over 30m the manufacturer recommends an external meter. Cloud monitoring is via Wi-Fi or LAN. A competent installer must commission it to BS 7671 and notify or apply to the DNO under G98/G99 as applicable.