The EHC SlimJim 10 kW Electric Flow Boiler with 170L Direct Cylinder (EHCSJ10/170) is a pre-matched boiler and unvented cylinder package for all-electric heating and hot water. A 100% efficient, flueless SlimJim boiler heats the radiators, while a stainless steel direct unvented cylinder with two 3 kW immersion heaters supplies mains pressure hot water.
The pack includes the 24/7 programmer, room thermostat, hot water programmer, high efficiency circulating pump, lockshield pump valves, 8 litre Robo kit, automatic air vent and magnetic filter, plus the cylinder's inlet control set, temperature and pressure relief valve, expansion vessel and tundish. You only need to add radiators, radiator valves and pipework.
EHC positions this pack for two-bedroom properties. Because the boiler is 100% efficient there is no need to oversize it, so size the installation from a heat loss calculation to BS EN 12831.
41.7 A
Boiler load current
25 Years
Cylinder warranty
Electrical safety, load check and unvented regulations
Have a qualified electrician carry out a load check before installation; the incoming supply may need upgrading. The manufacturer recommends 50 A protection for the boiler, a 30 mA double pole RCD and a minimum 10 mm² cable cross-section, with final sizing to BS 7671 by the electrician. The maximum permitted network impedance is 0.29 Ω. The two 3 kW immersion heaters must be included in the electrician's load assessment. The cylinder is an unvented hot water system, so it must be installed, commissioned and its discharge arranged by a G3-qualified installer to the Building Regulations.
How a direct cylinder works with this pack
The SlimJim boiler heats the radiators only. The direct cylinder heats domestic hot water with its two 3 kW immersion elements, controlled by the hot water programmer. Because a direct cylinder reheats more slowly than an indirect one, the manufacturer suggests considering an indirect cylinder pack for properties with high hot water demand. Radiators, valves and pipework are not included.
Key features
Complete pre-matched pack
Boiler, unvented stainless steel cylinder, controls, pump, Robo kit, air vent and magnetic filter are specified together, so there is one pack to order and fewer parts to source.
100% efficient, no flue
The insulated stainless steel heat exchanger converts all the electricity into heat, with no flue, no gas supply and no combustion analysis.
Compact SlimJim boiler
The wall-mounted boiler measures 912 x 203 x 172 mm and weighs 11 kg, designed to free up cupboard space.
Neptune stainless steel cylinder
A floor-standing 170 litre direct unvented cylinder with a 25 year warranty and 2 x 3 kW immersion heating.
Built-in boiler protection
A run-dry water level sensor, 100°C thermal cut-out and high current safety device protect the boiler, with in-built fault diagnostics for faster servicing.
Flexible control and system fit
Volt-free or 240 V control via a DIP switch, three selectable power stages, and suitability for radiators and wet underfloor heating on a sealed system.
Installation essentials
1. Site the boiler
Mount it upright on a wall with an adequate fixing. Allow 400 mm at the front and 50 mm each side. Fit frost protection where the room can fall below 0°C.
2. Site the cylinder
The floor-standing cylinder weighs 40 kg empty and 208 kg full, at 1200 x 510 mm. Check the floor can carry the full weight.
3. Connect the pipework
Flow (top) and return (bottom) are 22 mm compression and must never be reversed. Fit full bore lockshield isolation valves.
4. Filter, pump and air vent
Fit the magnetic filter on the return before the pump. Position the automatic air vent to the side of the boiler, never directly above it.
5. Cylinder safety discharge
The inlet control set, temperature and pressure relief valve and tundish must be piped to a safe discharge to G3 by a qualified installer.
6. Flush and commission
Flush to BS 7593, add inhibitor, and commission at a normal working pressure of about 1.0 to 1.5 bar. Clean the magnetic filter annually.
What is in the pack
Pack contents
Boiler
SlimJim 10 kW electric flow boiler
Cylinder
Neptune 170 litre direct unvented stainless steel cylinder (NDIR170L) with combination valve, temperature and pressure relief valve, DHW expansion vessel, tundish and 2 x 3 kW immersion elements
Controls
24/7 programmer, room thermostat, hot water programmer
Pump and system
High efficiency circulating pump, lockshield pump valves, 8 litre Robo kit, automatic air vent, magnetic filter
Documents
Installation and maintenance instructions, Benchmark logbook
Not included
Radiators, radiator valves and pipework
SlimJim pack range at a glance
Pack code
Boiler
Cylinder
Immersion
Protection
EHC sizing guide
EHCSJ7/120
7 kW
120 L direct
2 x 3 kW
40 A
1 bed
EHCSJ10/120
10 kW
120 L direct
2 x 3 kW
50 A
1 to 2 bed
EHCSJ10/150
10 kW
150 L direct
2 x 3 kW
50 A
1 to 2 bed
EHCSJ10/170
10 kW
170 L direct
2 x 3 kW
50 A
2 bed
EHCSJ10/170IND
10 kW
170 L indirect
1 x 3 kW
50 A
1 to 2 bed
Technical specification
Pack
Boiler
EHC SlimJim 10 kW single phase electric flow boiler
Cylinder
170L pack code, Neptune NDIR170L direct unvented
Cylinder type
Direct (2 x 3 kW immersion elements)
EHC sizing guide
2 bedrooms
Boiler
Heat output
10 kW (34,121 BTU/h)
Supply
240 V AC, single phase, 50 Hz
Recommended protection
50 A
Minimum cable cross-section
10 mm²
Maximum network impedance
0.29 Ω
Dimensions (H x W x D)
912 x 203 x 172 mm
Flow temperature
30 to 80°C
Overheat protection
100°C
System pressure
Minimum 0.5 bar, maximum 3 bar
Connections
22 mm compression, flow top, return bottom
Cylinder
Height x diameter
1200 x 510 mm
Weight empty / full
40 kg / 208 kg
Immersion heater
2 x 3 kW
Material
Stainless steel, unvented
Frequently asked questions
What is included in this pack?
The 10 kW SlimJim boiler, the 170 litre direct unvented cylinder, 24/7 programmer, room thermostat and hot water programmer, plus the pump, lockshield valves, 8 litre Robo kit, air vent and magnetic filter. Radiators, valves and pipework are not included.
How is the hot water heated?
The cylinder is direct: its two 3 kW immersion elements heat the water, while the boiler heats the radiators only. For higher hot water demand, consider an indirect pack.
What electrical supply does it need?
A 240 V single phase supply. The boiler draws 41.7 A and the manufacturer recommends 50 A protection, a 30 mA double pole RCD and a minimum 10 mm² cable, with final sizing to BS 7671 and a load check by a qualified electrician. Include the cylinder's immersion heater(s) in that assessment.
What size is the cylinder and how heavy is it?
The NDIR170L cylinder is 1200 mm high and 510 mm in diameter, and weighs 40 kg empty and 208 kg full.
Can I use it with underfloor heating?
Yes. The SlimJim suits wet underfloor heating as well as radiators, with a flow temperature of 30 to 80°C. Add the manufacturer's required controls for the underfloor circuit.
Who can install the unvented cylinder?
An unvented cylinder must be installed and commissioned by a G3-qualified installer, with the discharge pipework to the Building Regulations. The electrical work should be carried out by a qualified electrician to BS 7671.