The Telford 250L/50L Pre‑Plumbed Cylinder for Samsung (product code TSMI250/50/HP/PP/SAM) is a 250L Tempest unvented stainless‑steel heat pump cylinder with an integrated 50L buffer vessel, factory pre‑plumbed and pre‑wired to provide a fast, tidy installation with Samsung air source heat pumps.
Key Features
- Pre‑plumbed Tempest cylinder – duplex stainless‑steel unvented cylinder with pre‑fabricated 28mm pipework and wiring to minimise on‑site labour and first‑fix time.
- Integrated 50L buffer – built‑in 50L buffer store improves system volume, protects against short‑cycling and enhances heat pump defrost and flow stability.
- Heat pump optimised coil – large‑surface‑area coil specifically designed for low‑temperature heat pumps to maximise heat transfer and system efficiency.
- Mains‑pressure hot water – delivers high‑flow, mains‑pressure domestic hot water suitable for modern bathrooms and multiple outlets.
- Long‑life construction – Duplex stainless‑steel inner vessel with high‑performance insulation and robust fittings for durability and low standing heat losses.
Pre‑Installed Components
- Samsung control box and wired controller (MIM‑E03EN) – Samsung mono controller and user interface pre‑mounted and pre‑wired for seamless integration with compatible Samsung heat pumps.
- 3‑port diverter valve (pre‑wired) – factory‑wired diverter valve to manage DHW / heating priority without additional wiring centres.
- Secondary circulation pump – Grundfos pump (approx. 7.5m head) fitted on the secondary circuit to ensure correct flow through the cylinder and heating system.
- Integrated 50L buffer – internal buffer vessel within the cylinder assembly, eliminating the need for a separate external buffer tank.
- Filling loop and pressure gauge – pre‑installed filling kit and pressure gauge for easy filling, pressurisation and ongoing system checks.
- Safety and control components – 15–22mm tundish, temperature and pressure relief (T&P) valve, 22mm inlet group valve and automatic air vent, factory‑fitted for compliance and safety.
- Immersion heaters – 3kW immersion heater in the main tank and 3kW immersion heater in the buffer section for backup heating and pasteurisation cycles.
Other Included Accessories
- Samsung flow sensor – dedicated flow sensor included for correct control and monitoring by the Samsung heat pump system.
- Potable expansion vessel – expansion vessel supplied to manage domestic hot‑water expansion, typically complete with wall‑mounting bracket.
Cylinder Specifications
- Nominal DHW capacity: 250L.
- Integrated buffer volume: 50L.
- Empty weight: approximately 110kg.
- Full weight: approximately 357kg.
- Height: around 1778mm.
- Diameter: approximately 580mm.
- Primary coil size: around 3m² heat‑pump coil surface area.
Product Details & Performance
- Product code: TSMI250/50/HP/PP/SAM (Tempest Heat Pump with 50L Buffer Samsung Pre‑Plumbed, 250L).
- Standing heat loss: approximately 2.11kWh/24h (about 88W) under standard test conditions.
- Maximum primary pressure: 3 bar on the primary (heat pump) circuit.
- T&P valve setting: typically 7 bar / 90°C via the factory‑fitted T&P relief valve.
- Immersion heater rating: 3kW in the main cylinder and 3kW in the buffer vessel.
Compatibility & Applications
- Compatible heat pumps: specifically configured for Samsung Gen6, Gen7 and HTQ air source heat pumps and not suitable for Samsung integrated heat pumps which already incorporate a cylinder package.
- System type: indirect, unvented mains‑pressure hot‑water cylinder with integrated buffer, designed for use with a Samsung ASHP as the primary heat source.
- Ideal use cases: small to medium dwellings where a 250L cylinder with an integrated 50L buffer provides an optimal balance of DHW storage, plant‑room footprint and system stability.
Warranty & Registration
- Warranty: lifetime manufacturing warranty on the inner stainless‑steel vessel and 2‑year warranty on factory‑fitted components (terms and conditions apply).
- Registration: the cylinder must be registered with Telford after installation via the Telford online registration portal to validate the extended warranty.
- Type Heat Pump Cylinders
- Vendor Telford
- SKU TSMI250/50/HP/PP/SAM
BTU & WATT Calculator
Room Dimensions
Room Type
Living Room
Bedroom
Kitchen
Bathroom
Conservatory
Hallway
Glazing Type
Single Glazed
Double Glazed
Triple Glazed
External Walls
0 Wall
1 Wall
2 Walls
3 Walls
4 Walls
Insulation Level
Poor
Average
Good (New Build)
Required Heating
0
Watts
0
BTUs