The Revive2 500mm x 1000mm K2 Compact Radiator is a double panel, double convector (Type 22) central heating radiator built for rooms that need strong heat output from a slim, wall-hugging footprint. Twin steel panels sandwich two full-depth convector fins, giving this size a rated output of 1732W (5910 BTU/h) at the industry-standard Delta T50 test condition — enough to heat a well-insulated room quickly without the radiator dominating the wall.
Finished in durable powder-coated white (RAL 9016) with factory-fitted top grille and side panels, the K2 compact sits close to the wall and suits both domestic and light commercial installations on standard wet central heating systems. It is supplied complete with wall brackets, an air vent, a blanking plug and fixings, so it is ready to plumb in as soon as it is on the wall.
1732W
Heat Output
5910
BTU/h
500mm
Height
1000mm
Length
K2 / Type 22
Configuration
10 Year
Warranty
Please Note
Heat output figures (1732W / 5910 BTU/h) are the BS EN 442 Delta T50 certified standard for a K2 (Type 22) double panel, double convector compact radiator at 500mm x 1000mm — the harmonised European test condition (mean water temperature 70°C against a 20°C room). Always confirm the exact figure on your order confirmation before final room heat-loss calculations, as coating batch and panel tolerances can cause minor variation between production runs.
Double Panel, Double Convector
K2 (Type 22) construction: two full steel panels plus two convector fins deliver significantly higher output than a single-panel radiator of the same size.
Compact Wall Projection
Slim profile projects only around 100-135mm from the wall (including brackets), making it a practical fit for hallways, bathrooms and box rooms where space is tight.
Factory-Fitted Top Grille & Side Panels
Integrated top grille and closed end panels give a tidy, finished look straight out of the box and help direct convected heat efficiently into the room.
BS EN 442 Tested
Manufactured and tested to BS EN 442, the harmonised European standard for radiator heat output, pressure and safety performance.
10 Bar Rated
Rated to a maximum operating pressure of 10 bar, giving it headroom for pressurised and unvented central heating systems as well as standard open-vent setups.
10-Year Manufacturer Warranty
Backed by a 10-year warranty against manufacturing defects, giving long-term peace of mind on a radiator built for everyday use.
Dimensions
Height
500mm
Length
1000mm
Depth / Projection from wall
100mm (approx. 101-135mm including brackets, size dependent)
Performance
Heat output (Watts)
1732W
Heat output (BTU/h)
5910 BTU/h
Test standard
BS EN 442, Delta T50
Maximum operating pressure
10 bar
Construction
Configuration
K2 / Type 22 - double panel, double convector
Material
Cold-rolled steel
Finish
Powder-coated white, RAL 9016
Connections
4 x G½" internal thread (top and bottom, both sides)
What's included
Supplied with
Wall brackets, air vent, blanking plug, screws and wall plugs
Radiator valves
Not included - select compatible valves separately
Warranty
Manufacturer warranty
10 years
Is this a K2 or Type 22 radiator?
Both terms describe the same construction. "K2" and "Type 22" are interchangeable industry names for a double panel, double convector radiator - two full steel panels with two convector fins between them, giving higher output than a single panel (K1 / Type 11) radiator of the same dimensions.
What size room will this radiator heat?
At 1732W (5910 BTU/h), this size is generally suited to a small-to-medium room with reasonable insulation. Actual suitability depends on room volume, insulation standard, window area and target temperature, so we'd recommend running a proper heat-loss calculation for your specific room before ordering.
Does it come with a valve?
No. Radiator valves are sold separately so you can choose the type that suits your system - manual, thermostatic (TRV), or angled/straight/corner pattern to match your pipework.
Can this be used with a heat pump?
K2 compact radiators can be used on heat pump systems, but because heat pumps run at lower flow temperatures than a gas boiler, the actual heat output will be lower than the BS EN 442 Delta T50 figure quoted here. For heat pump installations, always size radiators against the manufacturer's low-temperature output data (typically Delta T30) rather than the standard Delta T50 rating.
What's the maximum operating pressure and temperature?
This radiator is rated to a maximum operating pressure of 10 bar, suitable for both vented and unvented (pressurised) central heating systems. As with all steel panel radiators, always check your specific system pressure and consult a qualified heating engineer if you're unsure.
BTU & WATT Calculator
Room Dimensions
Room Type
Living Room
Bedroom
Kitchen
Bathroom
Conservatory
Hallway
Glazing Type
Single Glazed
Double Glazed
Triple Glazed
External Walls
0 Wall
1 Wall
2 Walls
3 Walls
4 Walls
Insulation Level
Poor
Average
Good (New Build)
Required Heating
0