This system pairs the Samsung Mono 16kW air source heat pump (12.28kW nominal winter output) with the Joule Kodiak 200L Standard Pre-Plumbed Cylinder, giving the highest-capacity heat pump in the Samsung Gen 6 monobloc range a complete, coordinated hot water solution for large UK homes and light commercial properties. The Kodiak cylinder arrives factory pre-plumbed with its zonal control manifold already fitted, cutting installation time compared with plumbing a heat pump to a standard cylinder on site.
The patented modular zonal control manifold manages 3 zones - 1 hot water and 2 heating circuits - from a single compact unit, so radiators, underfloor heating, and domestic hot water can all run to their own independent temperature settings. The 16kW heat pump continues to operate down to -25°C outdoor air temperature, making it a robust choice for the highest heat loss properties this system range is designed to serve.
12.28kW
Winter Heating Output
200L
Cylinder Capacity
3 Zone
Pre-Plumbed Manifold
-25°C
Min. Operating Temp
65°C
Max Hot Water Temp
R32
Refrigerant (GWP 675)
Additional Components Are Not Included
This listing covers the Samsung 16kW heat pump and Joule Kodiak 200L Standard cylinder only. Items such as the potable expansion vessel, Y strainer with isolation valve, braided hoses, anti-vibration feet, and heat pump fluid are not included and should be ordered separately to complete the installation.
MCS-Certified Installation Required
Installation must be carried out by an MCS-certified installer to ensure compliance with UK regulations, to qualify for available government funding schemes such as the Boiler Upgrade Scheme, and to validate the full manufacturer warranty on both heat pump and cylinder.
Long-Term Warranty Cover
The heat pump carries a 7-year warranty when commissioned by Joule or a trained installer, while the Kodiak cylinder body is covered for up to 25 years with registration, and its components for 2 years - giving strong long-term protection across the whole system.
Highest Capacity in the Range
At 16kW nominal output, this is the largest heat pump in Samsung's Gen 6 monobloc line-up, suited to larger properties or higher-demand applications.
Factory Pre-Plumbed Cylinder
The 200L Kodiak Standard cylinder arrives with its hydraulic and zonal control manifold pre-fitted, cutting on-site plumbing time compared with a bare cylinder and separate control kit.
3-Zone Independent Control
The patented modular manifold manages 1 hot water zone and 2 heating zones independently, so radiators and underfloor heating can each run at their own optimum temperature.
True Monobloc Heat Pump
Samsung's Gen 6 outdoor unit has the entire refrigeration circuit factory-sealed, removing the need for on-site F-Gas handling.
Cold-Climate Performance at Scale
Rated to operate continuously down to -25°C outdoor air temperature, maintaining full heating output through the coldest UK winters even at this higher capacity.
Compatible Control Kits & Wi-Fi
Supports Samsung SmartThings app connectivity via an optional Wi-Fi kit for remote monitoring and control of heating and hot water.
Heat Pump Performance
Nominal Output (Summer Rating)
16 kW
Heating Output (A7/W35, Winter)
12.28 kW
Refrigerant Type
R32 (GWP 675)
Operating Range (Heating)
-25°C to +35°C outdoor
Max Hot Water Temperature
65°C
Power Supply
Single phase, 220-240V, 50Hz
Sound Level
Approx. 45 dB(A)
Dimensions (H x W x D)
1,420 x 940 x 330 mm
Kodiak 200L Standard Cylinder
Diameter
840 mm
Height
1,480 mm
Zones
3 (1 hot water, 2 heating)
Maximum Inlet Pressure
10 bar
Maximum Operating Pressure
7 bar
Mounting
Floor-standing
Warranty
Heat Pump
7 years when commissioned by Joule or a trained installer
Cylinder Body
25 years
Cylinder Parts
2 years
Why is the heat pump rated at both 16kW and 12.28kW?
16kW is the unit's nominal summer-rated capacity. In UK winter design conditions (A7/W35), the same unit delivers 12.28kW of usable heating output, which is the figure most relevant for sizing against a property's actual winter heat loss.
What comes in the box with this system?
This listing includes the Samsung 16kW heat pump and the 200L Kodiak Standard cylinder only. Additional components - expansion vessel, Y strainer, braided hoses, anti-vibration feet, and heat pump fluid - are not included and should be ordered separately.
What size property needs a 16kW heat pump?
The 16kW model is typically specified for large detached homes or small commercial buildings with substantial heat loss. An accurate heat loss calculation should always confirm the correct capacity for a specific property.
Is this cylinder suitable for a home with underfloor heating and radiators?
Yes. The 3-zone manifold is designed to run 1 hot water zone and 2 independent heating zones, making it well suited to properties combining underfloor heating in some areas with radiators elsewhere.
Is MCS certification required?
Yes. Installation should be carried out by an MCS-certified installer to comply with UK regulations, access funding schemes such as the Boiler Upgrade Scheme, and validate the manufacturer warranty.
BTU & WATT Calculator
Room Dimensions
Room Type
Living Room
Bedroom
Kitchen
Bathroom
Conservatory
Hallway
Glazing Type
Single Glazed
Double Glazed
Triple Glazed
External Walls
0 Wall
1 Wall
2 Walls
3 Walls
4 Walls
Insulation Level
Poor
Average
Good (New Build)
Required Heating
0
Watts
0
BTUs
Tools & Kits
Need a full system?