The Fox ESS EPS Box Pro HC-G2 is a three-phase backup box that sits between the grid, your Fox ESS inverter and your protected loads, so the home can keep running through a power cut. It automatically switches between On-Grid and Off-Grid state, with no manual changeover needed when the mains drops out or returns.
Built for residential power systems, the HC-G2 is rated for a maximum input current of 100A per phase on the utility supply and 100A per phase on the load output, with 63A per phase on the inverter grid and inverter EPS connections. It is housed in a robust IP65-rated enclosure, is wall-mounted, and is naturally cooled, so there are no fans to maintain.
It is compatible with the Fox ESS H3 Pro, AIO-H3, H3, H3 Smart, PQ3 and PQ3-Plus three-phase inverter ranges, and communicates with the system meter over an RS-485 interface.
Key Figures
100A
Max. input current per phase
100A
Max. load output per phase
63A
Inverter grid and EPS per phase
-25 to +60°C
Operating temperature
3L / N / PE
230 / 400V three-phase
Important Information
Installation and safety
Installation must be carried out by a competent, suitably qualified electrician in accordance with BS 7671 and the manufacturer’s installation manual. Isolate all supplies before opening the enclosure. Any connected generation or storage must be notified to the network operator under G98 / G99 as applicable.
Compatibility
The EPS Box Pro HC-G2 is a three-phase product (3L / N / PE) and is intended for the H3 Pro, AIO-H3, H3, H3 Smart, PQ3 and PQ3-Plus inverter ranges. Please confirm your inverter model before ordering. It is not intended for single-phase systems.
Rating difference
The HC-G2 is rated at 100A per phase on the utility and load sides, while its inverter grid and EPS connections are rated at 63A per phase. Check that your site supply and load design fall within these ratings.
Key Features
Automatic On-Grid / Off-Grid
Automatically switches to On-Grid or Off-Grid state as the mains fails or returns, keeping protected circuits supplied from your Fox ESS system.
100A Rated Utility and Load
100A per phase on the utility input and the load output, giving generous headroom for a whole-home backup arrangement.
IP65 Robust Enclosure
A robust IP65-rated enclosure protects against dust and water jets, and the unit operates from -25°C to +60°C.
Wide Inverter Compatibility
Works with the H3 Pro, AIO-H3, H3, H3 Smart, PQ3 and PQ3-Plus ranges, covering current and earlier Fox ESS three-phase systems.
RS-485 Meter Interface
Includes an RS-485 communication interface for the meter connection, supporting energy monitoring within the system.
Easy Wall-Mounted Installation
Wall-mounted with natural cooling, so no fans are needed. Compact at 420 x 550 x 139 mm and Class I, Overvoltage Category III rated.
Technical Specifications
MODEL
UTILITY SUPPLY
Rated Voltage [VAC]
220 / 380, 230 / 400, 3L / N / PE
Rated Frequency [Hz]
50 / 60
Max. Input Current (Per Phase) [A]
100
INVERTER GRID
Rated Voltage [VAC]
220 / 380, 230 / 400, 3L / N / PE
Rated Frequency [Hz]
50 / 60
Max. Input Current (Per Phase) [A]
63
INVERTER EPS
Rated Voltage [VAC]
220 / 380, 230 / 400, 3L / N / PE
Rated Frequency [Hz]
50 / 60
Max. Input Current (Per Phase) [A]
63
LOAD
Rated Voltage [VAC]
220 / 380, 230 / 400, 3L / N / PE
Rated Frequency [Hz]
50 / 60
Max. Output Current (Per Phase) [A]
100
COMMUNICATION INTERFACE
GENERAL DATA
Installation
Wall-mounted
Operating Temperature Range [°C]
-25 ~ +60
Dimensions (W*H*D) [mm]
420 * 550 * 139
Dimensions of Packing (W*H*D) [mm]
515 * 665 * 235
Humidity (No Condensation) [% RH at 40°C]
50
Max. Operating Altitude [m]
<4000 @ Derating exceeding 2000m
Pollution Degree
PD3 (outside), PD2 (inside)
Frequently Asked Questions
Which Fox ESS inverters work with the EPS Box Pro HC-G2?
It is compatible with the H3 Pro, AIO-H3, H3, H3 Smart, PQ3 and PQ3-Plus three-phase inverter ranges.
Can I use it on a single-phase system?
No. The HC-G2 is a three-phase product designed for 3L / N / PE supplies at 230 / 400V. Single-phase installations need a different solution.
Does it switch to backup automatically?
Yes. It automatically switches to On-Grid or Off-Grid state, so no manual changeover is required.
What current is it rated for?
The utility supply input and the load output are each rated at 100A per phase. The inverter grid and inverter EPS connections are each rated at 63A per phase.
Can it be installed outdoors?
It has an IP65 rating and an operating range of -25°C to +60°C, and is specified for pollution degree PD3 outside. It is wall-mounted, so follow the installation manual when choosing a position and always comply with BS 7671.
How does it connect to the meter?
Through the RS-485 communication interface, which is dedicated to the meter connection.