The 18mm Flat Dry Screed Overlay Board is a non-routed, flat-surface overlay panel designed to sit directly over grooved underfloor heating insulation boards. It gives you a smooth, stable, tile-ready surface at just 18mm thick, without a wet screed pour or the added floor height that comes with one.
Each 1200mm x 600mm board covers 0.72 m² and has tongue and groove edges that interlock and are bonded with joint adhesive, so no screws are needed. Thermal performance is strong for such a slim build-up: a thermal conductivity of 0.40 W/mK and a very low thermal resistance of 0.045 m²K/W let heat pass quickly from the pipework into the floor finish, which suits low flow temperature systems such as heat pumps as well as boilers.
Specify this board when the pipe is already housed in grooved insulation and you only need the covering layer for tiling or a self-levelled finish. Supplied with a minimum order of 10 boards (7.2 m²).
0.72 m²
Coverage per board
0.40 W/mK
Thermal conductivity
0.045 m²K/W
Thermal resistance
Tongue & groove
Screw-free edges
Designed to cover grooved insulation boards
This is a
flat board with no grooves. It is made to be laid
directly onto grooved insulation boards to create a durable, level surface for tiling.
Joint adhesive is required
Joint adhesive must be used on all joints and is
sold separately. The manufacturer calls for a 2-3mm layer of adhesive along the board edges, allowed to dry fully before the next stage. Add it to your order.
Solid, stable base required
Lay on a
solid, stable, dry subfloor. Timber floorboards must be screwed down firmly with no movement, and new screed or concrete must be checked for moisture before installation. Where a floor has to span joists, ask us about a
structural load-bearing panel instead.
Key features
Flat, non-routed surface
A
solid, groove-free face that gives a clean, continuous base over grooved insulation boards.
Low profile at 18mm
Only
18mm thick, keeping
floor build-up to a minimum on retrofit and new-build projects alike.
Fast heat transfer
0.40 W/mK conductivity and
0.045 m²K/W resistance deliver
rapid heat response and help the system run efficiently.
Screw-free joints
Tongue and groove interlocking edges are bonded with joint adhesive for
quick, simple installation without screws.
Stable and tough
Low thermal expansion,
high impact resistance, and it
does not contract or expand like chipboard when exposed to water.
Tile ready
Accepts
ceramic tiles directly, so you can go from board to finished floor without extra screed layers.
Technical specification
Product
Product type
Flat (non-routed) dry screed overlay board
Manufacturer code
GYPDECK 18
Edge profile
Tongue and groove, bonded with joint adhesive (no screws)
Dimensions and coverage
Board size
1200mm x 600mm
Coverage per board
0.72 m²
Minimum order
10 boards (7.2 m²)
Thermal performance
Thermal conductivity
0.40 W/mK
Thermal resistance
0.045 m²K/W
Performance and finishes
Moisture behaviour
Does not contract or expand like chipboard when exposed to water
Floor finish
Accepts ceramic tiles directly
Joint adhesive
Required on all joints, sold separately
Frequently asked questions
Does this board have grooves for the heating pipe?
No. This is the flat, non-routed version. It is designed to be laid over grooved insulation boards that carry the pipework. If you want the pipe routed into the overlay board itself, choose a routed board from the same range.
Do I need joint adhesive, and are screws required?
You need joint adhesive on all joints, but no screws. The tongue and groove edges interlock and are bonded with adhesive, which is sold separately. The manufacturer calls for a 2-3mm layer along the board edges, allowed to dry fully before moving on to the next stage of the installation.
Can I tile directly onto the board?
Yes. The board is designed to accept ceramic tiles directly. Use a flexible adhesive suitable for underfloor heating and follow the tile and adhesive manufacturers' guidance. Check the heat-up and commissioning requirements for your tiles before laying.
How many boards do I need?
Divide the floor area in m² by 0.72 and round up, then allow for cuts and offcuts. For example, a 15 m² area needs 15 ÷ 0.72 = 20.8, so 21 boards before any wastage allowance. The minimum order is 10 boards (7.2 m²).
How should the boards be laid, and what subfloor preparation is needed?
The subfloor must be solid, stable, dry and clean, with loose material removed and floorboards screwed down firmly. Check moisture content on new screed or concrete. Leave a 10mm expansion gap at the room perimeter and lay boards in a brick pattern, starting alternate rows with a half board. Full details are in the manufacturer's installation guide.
Can I use other floor finishes, and is it suitable for heat pumps?
The board is intended for tiled finishes. For vinyl, bonded wood or carpet, the manufacturer's guidance is to self-level the surface first. Always confirm the maximum permitted floor temperature with your flooring supplier, as around 27°C is commonly cited for wood and laminate. The board's low thermal resistance helps heat reach the floor surface at lower flow temperatures, which is valuable with heat pumps.