Biasi Multipoint Gas Water Heater Flue Accessories
FREE Express Delivery (1-3 days) in UK Mainland on most orders
Excluding: Solar Panels (£170 delivery / free above £2,500), Batteries (£49 delivery), Small Items (£4.95 delivery / free above £500)
Contact Us to check for Next Working Day Delivery or Same-day Delivery options
Contact Us for Click & Collect options
Custom quote available on request
*See checkout or shipping policy for full details
Payment options
Do you have a question
about this product?
One of our expert advisors will be happy to help you!
Contact Us
The Biasi Multipoint flue accessories range is designed exclusively for the Biasi Multipoint 14S and 16S gas instantaneous water heaters. The Multipoint uses a Ø 60/100 mm coaxial flue system (C13/C33 appliance type) — the same diameter as the Biasi condensing boiler range but with dedicated terminals and connectors specific to the Multipoint. These parts are not interchangeable with the condensing boiler flue accessories. The system must exit through an external wall or roof; the flue cannot be connected to a shared or common flue. All Multipoint flue accessories use push-fit connections with integrated seals. The Multipoint operates as a non-condensing water heater, so flue gas temperatures reach up to 118°C at nominal input — all accessories are rated accordingly.
Biasi Multipoint Flue Accessories
| Product | Part No. | Description |
| Wall Mount Kit | 10999.4111.0 | Wall mounting kit for the Biasi Multipoint 14S and 16S water heater. Provides the wall fixings, expansion screws, and mounting hardware required to securely hang the Multipoint on the installation wall. The Multipoint must be mounted vertically on a flat, stable surface capable of supporting the unit's weight. When the installation wall is a combustible material, a non-combustible heat-resistant mounting board exceeding the unit frame size by at least 10 mm in all directions must be used — this kit provides the fixing hardware for that board arrangement. Clearance requirements: 450 mm above, 50 mm each side, and 300 mm below the unit must be maintained to combustible materials. The installation template (Figure 5.6–5.8 in the Multipoint manual) shows the two top-hole and two bottom-hole fixing pattern with centres at 180 mm horizontally and 601 mm vertically. |
| Horizontal Flue Kit | 10999.1398.0 | Complete horizontal flue terminal kit for the Biasi Multipoint 14S and 16S, Ø 60/100 mm coaxial. Designed for a standard direct through-wall exit where the flue exits horizontally through an external wall. Includes the terminal, outer air duct, inner flue pipe, and wall plate with all seals. The Multipoint flue terminal is specific to the Multipoint water heater and must not be substituted with condensing boiler terminals (different part numbers apply). For installations requiring a longer horizontal run, add 1 m extensions (10999.0149.0) and elbows as required, staying within the maximum permitted flue length stated in the installation manual. The flue must slope slightly downward towards the terminal to allow condensate drainage away from the unit. |
| Vertical Flue Kit | 10999.1405.0 | Complete vertical flue terminal kit for the Biasi Multipoint 14S and 16S, Ø 60/100 mm coaxial. Used for roof-exit installations where a wall exit is not possible or practical. Includes the roof terminal, inner and outer pipes, and seals. An appropriate roof flashing plate must be sourced to suit the specific roof type (pitched or flat) — verify compatibility and roof penetration requirements before installation. For longer vertical runs, 1 m extension pieces (10999.0149.0) and pipe support brackets are required at the intervals specified in the installation manual. The Vertical Connection adapter (10999.1399.0) is used at the boiler collar to transition from the unit's top connection to the vertical flue pipe. |
| Vertical Connection Adapter | 10999.1399.0 | Vertical flue connection adaptor for the Biasi Multipoint 14S and 16S. Connects the coaxial flue collar at the top of the Multipoint unit to a vertical or angled flue run. This adaptor is the first piece of the flue system at the boiler on a vertical installation, transitioning from the unit's integrated flue collar to the standard 60/100 mm coaxial pipe system. Required on all vertical flue installations and on horizontal runs that route upward before turning horizontally. Supplied with integrated push-fit seal. Note: the Multipoint flue collar connection geometry differs from the condensing boiler range — always use Multipoint-specific adaptor parts. |
| 1 m Flue Extension | 10999.0149.0 | 1 metre coaxial flue extension for the Biasi Multipoint 14S and 16S, Ø 60/100 mm. Used to extend the flue run beyond the length provided in the terminal kit — on either horizontal or vertical routes. Each extension adds 1 m to the total flue run. Combine with 90° elbows (10999.0152.0) and 45° elbows (10999.0153.0) to navigate corners and obstructions. The total extended run must remain within the maximum permitted flue length for the Multipoint as stated in the installation manual. Push-fit connection with integrated seal — no additional sealant or adhesive required. |
| 90° Flue Elbow | 10999.0152.0 | 90° coaxial elbow for the Biasi Multipoint 14S and 16S flue system, Ø 60/100 mm. Changes the direction of the flue run by 90° — used to route the flue around structural obstacles, over ceilings, or to turn from a vertical to a horizontal run. Each 90° elbow deducts from the maximum permitted flue length — refer to the Biasi Multipoint installation manual for the exact deduction value. Push-fit connection with integrated seal. Do not use condensing boiler 90° elbows (e.g. 10999.0390.1) on the Multipoint — Multipoint-specific elbows must be used. |
| 45° Flue Elbow | 10999.0153.0 | 45° coaxial elbow for the Biasi Multipoint 14S and 16S flue system, Ø 60/100 mm. Provides a gentler 45° change of direction — useful for angling the flue gradually away from a wall surface, routing around shallow obstructions, or improving flue aesthetics where a 90° elbow would be intrusive. Each 45° elbow deducts a smaller amount from the maximum permitted flue length than a 90° elbow — refer to the Biasi Multipoint installation manual for the exact deduction value. Two 45° elbows can be used in place of a single 90° elbow where a smoother bend is preferred. Push-fit connection with integrated seal. |
Quick Reference — Multipoint Flue Accessories at a Glance
Frequently Asked Questions