Biasi Multipoint 16S Natural Gas Instantaneous Water Heater 30kW ErP A
FREE Express Delivery (1-3 days) in UK Mainland on most orders
Excluding: Solar Panels (£170 delivery / free above £2,500), Batteries (£49 delivery), Small Items (£4.95 delivery / free above £500)
Contact Us to check for Next Working Day Delivery or Same-day Delivery options
Contact Us for Click & Collect options
Custom quote available on request
*See checkout or shipping policy for full details
Payment options
Do you have a question
about this product?
One of our expert advisors will be happy to help you!
Contact Us
The Biasi Multipoint 16S (model code SV16S, MPN MPNG) is a 30kW room-sealed gas instantaneous water heater designed for properties with high or simultaneous hot water demand. Manufactured by BSG Caldaie a Gas S.p.A. in Pordenone, Italy — part of the Biasi Group — it delivers up to 16 litres per minute of continuous hot water on natural gas (G20, 20 mbar) and activates automatically from a minimum inlet pressure of just 0.2 bar (2.5 L/min). A microcomputer intelligent control system reads the water flow sensor, inlet temperature sensor and outlet temperature sensor simultaneously, adjusting the proportional gas valve in real time to hold the outlet at exactly the temperature set on the digital LCD touch panel — regardless of changes in flow rate or inlet temperature. The AI memory function retains the last set temperature so the unit is ready at the preferred setting from the first draw. Output is adjustable from 35°C to 65°C. ErP water heating energy efficiency class A (ηwh 80.5%), declared load profile XL. Appliance type C13/C33 — room-sealed fan-assisted — with a 60/100 mm coaxial flue (horizontal or vertical). IPX4 electrical protection rating. 2-year parts and labour guarantee when registered with Biasi UK within 30 days of purchase.
Installation, commissioning, and servicing of the Biasi Multipoint 16S must be carried out by a Gas Safe registered engineer in full compliance with the Biasi installation manual, the Gas Safety (Installation and Use) Regulations 1998, and current Building Regulations. A 60/100 mm coaxial flue kit and a switchable fused spur must be provided. The Benchmark commissioning checklist must be completed and signed at handover. Annual servicing by a Gas Safe registered engineer is strongly recommended to maintain safe operation and warranty validity.
This listing is for the natural gas (G20, 20 mbar) version only — MPN MPNG. The unit leaves the factory set for G20; it must not be connected to LPG without first fitting the appropriate Biasi conversion kit (Gas Safe registered engineer task). A 60/100 mm coaxial flue assembly is required for installation and is not included — order the matching Biasi horizontal or vertical flue kit separately. The 2-year guarantee must be registered with Biasi UK within 30 days of purchase by calling 01922 714600.
Press the @ function key in standby to cycle between three modes. Normal (default): user-set temperature, 35–65°C. Auto: the microcomputer automatically maps the outlet temperature to the measured inlet temperature — e.g. ≤15°C inlet → 45°C outlet, 22–27°C inlet → 40°C outlet — ideal for year-round comfort without manual seasonal adjustment. Eco: the microcomputer modulates gas supply to minimise consumption while maintaining the set temperature — best for lower-demand periods. All three modes are available at any set temperature within the 35–65°C range.
The CPU chipset simultaneously reads the water flow sensor, inlet temperature sensor, and outlet temperature sensor, then adjusts the proportional gas valve within milliseconds to deliver the set temperature precisely. Unlike basic on/off instantaneous heaters that require manual tap-blending, the 16S holds the outlet at the set point whether one or two outlets are open — no adjustment needed mid-draw.
At 16 L/min at a 25°C temperature rise (based on a ~12°C cold inlet delivering ~37°C at the outlet), the 16S is rated for genuine simultaneous use — a shower and a basin running concurrently without the temperature faltering. The 30kW nominal heat input (27.4kW useful output on G20) underpins this high flow capacity. Compared to the 14S (28kW / 14 L/min), the 16S provides approximately 14% more peak flow — meaningful in busy households or back-to-back commercial washroom use.
The 16S fires at a minimum inlet pressure of 0.2 bar (0.02 MPa) and minimum flow rate of 2.5 L/min — among the lowest activation thresholds for a 30kW instantaneous heater. This makes it suitable for upper-floor flats, loft conversions, rural properties, and any location where mains pressure can be marginal. The fan-assisted type C room-sealed flue draws combustion air from outside, removing any dependency on room ventilation and widening the range of viable installation locations.
The digital LCD display shows the set outlet temperature, live flame feedback, fan status, and draw-off indicator. Two soft-touch buttons step temperature in 1°C increments from 35–48°C, then in 5°C steps to 65°C. The AI memory function retains the last-used temperature after power cycling — no reprogramming on restart. The function mode also displays real-time gas consumption in m³/h during operation, and cumulative water and gas usage over the appliance's lifetime — useful for running cost monitoring and maintenance planning.
Nine independent safety circuits are built in: self-check protection, flame-out protection, over-heat protection, accidental power-cut protection, fan breakdown protection, electric overload protection, electric leakage protection, high wind pressure protection, and over-temperature protection. The child lock function prevents the temperature being raised above 48°C while the hot water outlet is open — the padlock icon flashes on the display when this threshold is approached, preventing accidental scalding.
Made by BSG Caldaie a Gas S.p.A. in Pordenone, Italy. The 16S achieves NOx Class 6 — the highest available — with weighted NOx of 30.53 ppm (47 mg/kWh). ErP water heating efficiency Class A (ηwh 80.5%), declared load profile XL, confirming suitability for high-demand applications. Compliant with Gas Appliances Regulation (EU) 2016/426, Ecodesign Directive 2009/125/EC, EMC Directive 2014/30/EU, and Low Voltage Directive 2014/35/EU. Destination country certification: GB / IE.
| Technical Specifications — Biasi Multipoint 16S (SV16S) — Natural Gas G20 | |
|---|---|
| Identity & Classification | |
| Model / MPN | Biasi Multipoint 16S — SV16S — MPNG |
| Appliance Type | C13/C33 — room-sealed fan-assisted instantaneous |
| Gas Category | II2H3P / II2H3B/P |
| Destination Country | GB / IE |
| Heat & Flow Performance (G20 Natural Gas) | |
| Nominal Heat Input (Hi) | 30.0 kW |
| Max. Nominal Heat Output (G20) | 27.4 kW |
| Min. Heat Input (G20) | 9.5 kW |
| Min. Heat Output (G20) | 8.7 kW |
| Max. Flow Rate (25°C rise) | 16 L/min |
| Min. Activation Flow Rate | 2.5 L/min |
| Min. Water Inlet Pressure | 0.2 bar (0.02 MPa) |
| Max. Water Pressure | 10 bar |
| Outlet Temperature Range | 35°C – 65°C (1°C steps 35–48°C; 5°C steps 48–65°C) |
| Gas Supply (G20 Natural Gas) | |
| Gas Type | Natural Gas G20 — 2H |
| Nominal Gas Supply Pressure | 20 mbar (2,000 Pa) |
| Min. Gas Supply Pressure | 17 mbar (1,700 Pa) |
| Max. Gas Supply Pressure | 25 mbar (2,500 Pa) |
| Max. Gas Flow Rate (Nom., Hi) | 3.17 m³/h |
| Min. Gas Flow Rate (Hi) | 1.01 m³/h |
| Flue & Combustion (G20) | |
| Flue Duct Diameter | Ø60 × Ø100 mm coaxial (C13 horizontal / C33 vertical) |
| Max. Flue Gas Temperature | 118°C (at 60/80°C, G20) |
| CO₂ Content (Nominal Input) | 5.16% |
| CO Content (Nominal Input) | 229 ppm |
| ErP & Emissions | |
| Water Heating Efficiency (ηwh) | 80.5% — Class A |
| Declared Load Profile | XL |
| Annual Fuel Consumption (AFC) | 19 GJ |
| Annual Electricity Consumption (AEC) | 14 kWh |
| NOx Class | Class 6 |
| Weighted NOx | 30.53 ppm — 47 mg/kWh |
| Electrical & Physical | |
| Power Supply | 230 V ~ 50 Hz — switchable fused spur required |
| IP Rating | IPX4 |
| Ignition | Water-controlled automatic pulse ignition |
| Indoor Sound Power Level (LWA) | 63 dB(A) |
| Dimensions (H × W × D) | 616 × 345 × 187 mm |
| Gas / Water Connections | G ½" — gas inlet, cold water inlet, hot water outlet |
| Guarantee | 2 years parts & labour — register within 30 days at Biasi UK: 01922 714600 |