The Sunamp Optimino Keys for Heat Pumps range lets a Sunamp Thermino xPlus heat battery work with your air source heat pump. Each key is brand-specific: it is matched to a named heat pump make and series, so the xPlus is configured correctly for the unit that charges it. Choose an hp key (code 01) for heat pump charging, or an hpPV key (code 02) to add solar PV alongside the heat pump.
The xPlus is Sunamp’s small and smart alternative to an indirect hot water cylinder: up to 4x smaller, Energy Class A+, ultra low heat losses and mains-pressure hot water with recommended flow rates of 15, 20 and 25 litres per minute across the 150, 210 and 300 models. There is no mandatory annual maintenance on the appliance and the design minimises the risk of Legionella.
Optimino keeps the heat battery future-proof. Start with a boiler today, move to a heat pump later, then add solar PV, each time by changing the key rather than the heat battery. Sunamp’s compatibility list covers 22 heat pump brands across R290, R32 and R454C refrigerants.
01 / 02
hp key or hpPV key
xPlus
150, 210 and 300 models
R290 · R32 · R454C
Refrigerants covered
22
Heat pump brands on Sunamp’s list
Match the key to your exact heat pump
Every key is specific to one heat pump brand and series. Check your model against the tables below before ordering. These keys are for the Thermino xPlus only: a Thermino ePlus cannot be used with a heat pump and takes the PV02 key for solar PV instead.
01 or 02: which key?
01 = hp key: the xPlus is charged by the heat pump. 02 = hpPV key: heat pump plus solar PV. A compatible solar diverter is required with any 02 key (4-Noks Power Reducer SA, myenergi eddi, my-PV AC·THOR or Power Diverter Model 3) and is sold separately.
Electrical safety and scald protection
Wiring must be carried out by a competent person in line with BS 7671, with all supplies to the heat battery, heat pump and any solar diverter isolated first. In line with UK Building Regulations, Sunamp advises fitting a hot water tempering valve at the outlet to prevent the risk of scalding (recommended TMV setting 45–55°C).
Key features and benefits
Brand-matched compatibility
Keys are available for 22 heat pump brands, from Daikin, Vaillant and Samsung to Panasonic, Mitsubishi Electric, Ideal, Grant and Stiebel Eltron.
Heat pump only, or heat pump plus PV
Pick the 01 hp key for heat pump charging or the 02 hpPV key to add solar PV diversion with a compatible diverter.
Swap the key, keep the battery
Move from boiler (VF key) to heat pump (hp key) to heat pump plus PV (hpPV key) without replacing the xPlus.
Compact and efficient
The xPlus is up to 4x smaller than an indirect cylinder, rated Energy Class A+, with heat loss of just 0.67 to 0.84 kWh per 24 hours.
Mains-pressure performance
Recommended flow rates of 15, 20 and 25 L/min (150, 210, 300) deliver invigorating mains-pressure showers and on-demand hot water.
Documented for installers
Sunamp publishes a brand-specific wiring and settings document (D0086) for each heat pump, alongside the D0084 xPlus installation manual.
Available keys on this listing
Listing option
Key code
Key type
Heat pump series (Sunamp-listed)
Wiring document
xPlus Ideal Heat Pumps Key
IL01
hp key
Ideal HP290 R290 Monobloc
D0086-IL
xPlus Midea Heat Pumps Key
MA01
hp key
Midea MHC R290
D0086-MA
xPlus Samsung Heat Pumps Key
SG01
hp key
Samsung EHS HTQ R32 series; Samsung EHS Mono R290
D0086-SG
xPlus Panasonic Heat Pumps Key
PC01
hp key
Panasonic L series R290; Panasonic M series R290
D0086-PC
xPlus Daikin Heat Pumps Key
DN01
hp key
Daikin Altherma 3HHT R32 series
D0086-DN
xPlus Vaillant Heat Pumps Key
VT01
hp key
Vaillant Arotherm Plus R290 series
D0086-VT
xPlus Mitsubishi Electric Key
MC01
hp key
Mitsubishi Electric PUZ-WZXXVAA R290
D0086-MC
xPlus Grant Aerona Key
GT01
hp key
Grant Aerona HPR290 series
D0086-GT
xPlus Grant Aerona +PV Key
GT02
hpPV key (with PV)
Grant Aerona HPR290 series
D0086-GT
xPlus Stiebel Eltron +PV Key
SL02
hpPV key (with PV)
Stiebel Eltron WPL-A 07 HK 230 Premium R454C; HPA-O Trend HC 230 R290; HPA-O Plus HC 230 R290
D0086-SL
Technical specification
Key identity
Product
Optimino keys for heat pumps (hp and hpPV)
Key codes
01 = hp key (heat pump); 02 = hpPV key (heat pump plus solar PV). Brand prefix identifies the heat pump make, for example SG01 and SG02 for Samsung
Key type
Optimino energy-source key (plug-in)
Compatible heat battery
Thermino xPlus 150, 210 and 300
Refrigerants covered
R290, R32 and R454C heat pumps (series-specific)
Solar diverter (02 keys)
Required, sold separately: 4-Noks Power Reducer SA; myenergi eddi; my-PV AC·THOR; Power Diverter Model 3
Thermino xPlus heat battery (Sunamp data sheet)
Models
150 xPlus · 210 xPlus · 300 xPlus
Equivalent hot water cylinder size
128 L · 192 L · 256 L
V40 (litres of hot water at 40°C)
167 L · 271 L · 333 L
Heat loss rate
0.67 kWh/24h (28.1 W) · 0.77 kWh/24h (32.1 W) · 0.84 kWh/24h (34.9 W)
Energy efficiency rating class
A+
Heating element (230 V, 50 Hz)
1,800 W or 2,800 W
Manufacturer part numbers, 1,800 W
BKP-KNW-AVZ-1 · BNP-KNW-AVZ-1 · BRP-KNW-AVZ-1
Manufacturer part numbers, 2,800 W
DKP-KNW-AVZ-1 · DNP-KNW-AVZ-1 · DRP-KNW-AVZ-1
Recommended maximum flow rate
15 L/min · 20 L/min · 25 L/min
Minimum mains supply pressure
1.5 bar (0.15 MPa)
Maximum working pressure
5 bar (0.5 MPa)
Recommended TMV temperature
45–55°C
Product weight in use
136 kg · 187 kg · 233 kg
Dimensions (W × D × H)
365 × 575 × 640 mm (150) · 870 mm (210) · 1050 mm (300); pipe access on 3 sides
Installation and documentation
Fitting
Plug-in key for the heat battery’s Optimino controller; swap the key to change energy source, no new heat battery needed
Installer
Competent person; isolate heat battery, heat pump and any solar diverter supplies before working
Heat battery manual
D0084 Thermino xPlus installation and user instructions
Heat pump wiring and settings
D0086, one document per heat pump brand (for example D0086-DN for Daikin)
Solar PV wiring and settings
D0085 (02 keys)
Technical notes
D0093 back-up electric mode; D0104 mandatory plumbing components; D0114 cold commissioning
Full Sunamp heat pump compatibility list
Compatible heat pump
hp key (without PV)
hpPV key (with PV)
Amitime PAVH-08V1GFB R290
AE01
AE02
AUX ACHP R290 Monoblock
AX01
AX02
Bosch Compress 5800i AW R290
BH01
BH02
Daikin Altherma 3HHT R32 series
DN01
DN02
Ecoforest ecoAIR PRO series
ET01
ET02
Ecoforest ecoGEO PRO R290 series
ET01
ET02
Grant Aerona HPR290 series
GT01
GT02
Haier Monobloc GT R290 series
HR01
HR02
Hisense Hi-Therma R290 Monobloc
HE01
HE02
Ideal HP290 R290 Monobloc
IL01
IL02
LG Therma V Monobloc R290 series
LG01
LG02
Mitsubishi Electric PUZ-WZXXVAA R290
MC01
MC02
NIBE S2125 R290
NE01
NE02
Panasonic L series R290
PC01
PC02
Panasonic M series R290
PC01
PC02
Phnix Greentherm R290 series
PX01
PX02
Samsung EHS HTQ R32 series
SG01
SG02
Samsung EHS Mono R290
SG01
SG02
Stiebel Eltron WPL-A 07 HK 230 Premium R454C
SL01
SL02
Stiebel Eltron HPA-O Trend HC 230 R290
SL01
SL02
Stiebel Eltron HPA-O Plus HC 230 R290
SL01
SL02
Tongyi R290 Inverter series TAHMV-R
TI01
TI02
Trianco Activair R290 series
TO01
TO02
Vaillant Arotherm Plus R290 series
VT01
VT02
Viessmann Vitocal R290
VN01
VN02
Need a key for a brand not listed on this page? Contact our team and we will check availability against Sunamp’s compatibility list above.
Frequently asked questions
What is a Sunamp Optimino heat pump key?
It is a plug-in configuration key for the Optimino controller inside a Thermino xPlus. It tells the heat battery which heat source is charging it, so the xPlus works correctly with your specific heat pump make and series.
What is the difference between the 01 and 02 keys?
The 01 key (hp key) configures the xPlus for heat pump charging. The 02 key (hpPV key) does the same and also enables solar PV. A 02 key needs a compatible solar diverter, which is sold separately.
Which key do I need for my heat pump?
Match your brand and series to the tables above. For example, a Daikin Altherma 3HHT R32 uses DN01 (or DN02 with PV), a Vaillant Arotherm Plus R290 uses VT01 (or VT02), and a Samsung EHS HTQ R32 or Mono R290 uses SG01 (or SG02).
Can I use these keys with a Thermino ePlus?
No. Heat pump keys are for the Thermino xPlus. The ePlus is a grid-electric heat battery that adds solar PV with the PV02 key.
Can I start with a boiler and switch to a heat pump later?
Yes. That is the purpose of Optimino. An xPlus can start with a boiler key (VF01, or VF02 with PV), then move to a heat pump key when the heat pump is installed, without replacing the heat battery.
Where do I find the wiring instructions?