{"product_id":"yy-control-flexible-cable-4-core-1-5mm-50m-yy1-54c050","title":"YY Control Flexible Cable 4 Core 1.5mm 50m | YY1.54C050","description":"\u003c!-- SEO Product Name: Doncaster YY Control Flexible Cable 4 Core 1.5mm 50m | YY1.54C050 --\u003e\n\u003cdiv style=\"font-size:16px;max-width:900px;margin:0 auto;line-height:1.6;color:#222;font-family:Arial,Helvetica,sans-serif;\"\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eDoncaster YY is an \u003cstrong\u003eunscreened, flexible PVC control cable\u003c\/strong\u003e with a \u003cstrong\u003egrey PVC sheath\u003c\/strong\u003e, used to link fixed and mobile equipment. This \u003cstrong\u003e4 core 1.5 mm² 50 m reel\u003c\/strong\u003e suits \u003cstrong\u003eindoor to outdoor unit wiring on single and multi split air conditioning systems\u003c\/strong\u003e where the unit manufacturer allows a control-type cable.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eThe \u003cstrong\u003eplain annealed copper conductors\u003c\/strong\u003e are flexible, and the \u003cstrong\u003ePVC insulation and sheath\u003c\/strong\u003e keep the cable slim at \u003cstrong\u003e8.8 mm overall diameter\u003c\/strong\u003e, so it is easy to route through trunking and clip along walls. It is rated \u003cstrong\u003e300\/500 V\u003c\/strong\u003e, works from \u003cstrong\u003e−15 °C to +70 °C\u003c\/strong\u003e and has a \u003cstrong\u003eminimum bending radius of 6 times the cable diameter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:26px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e4 core\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003e1.5 mm² conductors\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e50 m\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eReel length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e8.8 mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eOverall diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e300\/500 V\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eVoltage rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e−15 to +70 °C\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eOperating temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e6 x ∅\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eMinimum bending radius\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #c0392b;background:#fdf2f2;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#c0392b;margin-bottom:5px;\"\u003e⚠ Electrical work: competent person only\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eFixed wiring must be designed and installed to BS 7671 by a competent person. In dwellings in England, new circuits are notifiable under Part P of the Building Regulations. Size the cable and its protective device for the unit's rated current, the cable length and the installation method.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #e67e22;background:#fdf8f2;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#b35f00;margin-bottom:5px;\"\u003e⚠ Best suited to indoor use\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eDoncaster states that, if protected correctly, YY can be used in outdoor projects, but it is recommended and most commonly used indoors in dry or moist conditions. Run it in conduit or trunking where it is exposed outside, and note it is unscreened.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #008377CF;background:#f0f9f8;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00695f;margin-bottom:5px;\"\u003eℹ Follow the unit manual\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eAir conditioning manufacturers specify the cable type, number of cores and cross-sectional area for the power supply and the indoor to outdoor interconnection. Check the installation manual for your indoor and outdoor units before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;margin:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🔌\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eFlexible copper conductors\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003e\n\u003cstrong\u003ePlain annealed copper\u003c\/strong\u003e conductors that are flexible and easy to terminate.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e📏\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eSlim 8.8 mm profile\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eAn \u003cstrong\u003eoverall diameter of 8.8 mm\u003c\/strong\u003e makes it easy to route through trunking and small wall penetrations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🧱\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eTough grey PVC sheath\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003e\n\u003cstrong\u003ePVC insulation and PVC sheath\u003c\/strong\u003e (types TI2 and TM2) for durable general indoor use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🌡️\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eTemperature range\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eOperates from \u003cstrong\u003e−15 °C to +70 °C\u003c\/strong\u003e, with a minimum bending radius of \u003cstrong\u003e6 x ∅\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🔗\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eLinks fixed and mobile equipment\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eFlexible construction suits \u003cstrong\u003elinking fixed and mobile equipment\u003c\/strong\u003e as well as light mechanical stress.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e📦\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003e50 m reel\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eA \u003cstrong\u003e50 m reel\u003c\/strong\u003e covers typical indoor to outdoor runs, with enough over for several installs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"margin:18px 0 26px;border:1px solid #d5e8e6;border-radius:6px;overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eProduct\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eBrand\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eDoncaster Cables\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eType\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eYY PVC insulated and sheathed flexible control cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eManufacturer part number\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eYY1.54C050 (50 m reel)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eCores\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e4\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eConductor size\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e1.5 mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eReel length\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e50 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eConductor\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePlain annealed copper\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eInsulation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePVC type TI2 to BS EN 50363-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eSheath\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePVC type TM2 to BS EN 50363-4-1, grey\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eScreen\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eNone (unscreened)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eOverall diameter\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e8.8 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eElectrical and thermal\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eVoltage rating\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e300\/500 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eOperating temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e−15 °C to +70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eMinimum bending radius\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e6 x overall diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdiv style=\"margin:18px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eIs YY cable suitable for connecting indoor and outdoor air conditioning units?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eIt is commonly used to link equipment, but the cable type, core count and size must match the unit manufacturer's specification. Check the installation manual for your indoor and outdoor units before ordering.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eIs YY cable screened?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eNo. YY is unscreened. If you need a screen or mechanical protection from a braid, look at the SY (steel braid) or CY (copper braid) control cables instead.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eCan I use it outdoors?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eDoncaster says YY can be used outdoors if protected correctly, but recommends it for indoor use in dry or moist conditions. Use conduit or trunking where it is exposed to weather or damage.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eWhat size and number of cores do I need?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eThis depends on the units. Count the terminals between the indoor and outdoor unit in the wiring diagram and use the cross-sectional area the manual specifies.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eWhat is the minimum bending radius?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eSix times the overall cable diameter, so about 53 mm for this 8.8 mm cable.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":67575686660486,"sku":"Y1.54C050","price":147.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/YYControlFlexibleCable4Core1.5mm.png?v=1791273084","url":"https:\/\/qualityheating.co.uk\/products\/yy-control-flexible-cable-4-core-1-5mm-50m-yy1-54c050","provider":"AIZO Quality Heating","version":"1.0","type":"link"}