{"product_id":"xpelair-simply-silent-shower-fan-complete-sssfc-100mm-timer-93086aw","title":"Xpelair Simply Silent Shower Fan Complete SSSFC 100mm Timer 93086AW","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,sans-serif;color:#333;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eXpelair Simply Silent™ Shower Fan Complete (SSSFC, 93086AW)\u003c\/strong\u003e is a \u003cstrong\u003epurpose-designed in-shower extractor fan kit\u003c\/strong\u003e that installs directly within the shower cubicle ceiling — extracting steam and moisture \u003cstrong\u003eat the point of generation\u003c\/strong\u003e rather than from a remote wall position. Powered by Xpelair's \u003cstrong\u003eGhost™ Air Movement Technology\u003c\/strong\u003e, the fan runs at either \u003cstrong\u003e15 or 21 l\/s\u003c\/strong\u003e with a remarkable \u003cstrong\u003e22 dB(A) low-speed noise level\u003c\/strong\u003e. The in-shower position delivers an \u003cstrong\u003e88% better installed extraction rate\u003c\/strong\u003e than comparable loft-mounted inline fans, because there is no performance loss through a long ceiling void duct run. Supplied as a \u003cstrong\u003ecomplete ceiling kit\u003c\/strong\u003e including 3m flexible ducting, external grille, and fixings — everything needed for a clean, compliant installation. Complies with \u003cstrong\u003eBuilding Regulations Part F\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- STAT STRIP --\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin:20px 0;\"\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003e22 dB(A)\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003eLow-speed noise\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003e21 l\/s\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003eHigh-speed extract\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003e88%\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003eBetter than inline\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003e6.0\/6.7W\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003ePower draw\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003eIPX4\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003eIP rating\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"background:#008377;color:#fff;padding:12px 16px;border-radius:6px;flex:1;min-width:115px;text-align:center;\"\u003e\n\u003cstrong style=\"font-size:18px;\"\u003e2 Years\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:12px;\"\u003eWarranty\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- CALLOUTS --\u003e\n\u003cdiv style=\"background:#f8d7da;border-left:4px solid #c0392b;padding:12px 16px;border-radius:4px;margin:12px 0;\"\u003e\n  \u003cstrong\u003eElectrical Safety — Zone 1 Installation:\u003c\/strong\u003e This fan is rated \u003cstrong\u003eIPX4\u003c\/strong\u003e and is designed for \u003cstrong\u003eceiling installation directly above the shower tray\u003c\/strong\u003e, which constitutes \u003cstrong\u003eZone 1\u003c\/strong\u003e under \u003cstrong\u003eBS 7671 (IET Wiring Regulations)\u003c\/strong\u003e. The circuit supplying this fan \u003cstrong\u003emust be protected by a 30mA RCD\u003c\/strong\u003e. The protective fuse must not exceed \u003cstrong\u003e5A\u003c\/strong\u003e. Use a \u003cstrong\u003edouble-pole isolating switch\u003c\/strong\u003e with at least 3mm contact separation. Ensure the unit is wired by a qualified electrician. The unit operates at \u003cstrong\u003e230V mains voltage\u003c\/strong\u003e — if a 12V SELV installation is preferred (e.g. no RCD available), see the \u003cstrong\u003eIllumi (93087AW)\u003c\/strong\u003e.\n\u003c\/div\u003e\n\u003cdiv style=\"background:#d4edda;border-left:4px solid #008377;padding:12px 16px;border-radius:4px;margin:12px 0;\"\u003e\n  \u003cstrong\u003eSpeed Selection at Installation:\u003c\/strong\u003e The two speeds — \u003cstrong\u003eLow (15 l\/s \/ 54 m³\/h, 22 dB)\u003c\/strong\u003e and \u003cstrong\u003eHigh (21 l\/s \/ 76 m³\/h, 34 dB)\u003c\/strong\u003e — are set by a link inside the fan housing during installation. High speed is recommended for compliance with \u003cstrong\u003ePart F\u003c\/strong\u003e minimum extract rates. Low speed gives near-silent background operation for less demanding use patterns.\n\u003c\/div\u003e\n\n\u003c!-- FEATURE CARDS --\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;margin:24px 0;\"\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eIn-Shower Position — Why It Matters\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eA conventional wall-mounted bathroom extractor draws humid air across the full room before it reaches the fan. By positioning the SSSFC \u003cstrong\u003edirectly within the shower enclosure ceiling\u003c\/strong\u003e, steam is captured at source before it can migrate to cold surfaces and walls. This is why installed performance is \u003cstrong\u003e88% better\u003c\/strong\u003e than a remote inline fan drawing through the same duct length.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eGhost™ Air Movement Technology\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eThe DX100BTR fan unit at the heart of this kit uses \u003cstrong\u003eGhost technology\u003c\/strong\u003e — precision-engineered impeller geometry and ultra-low-vibration motor bearings that eliminate the two primary sources of fan noise: aerodynamic turbulence and mechanical resonance. At low speed, \u003cstrong\u003e22 dB(A) at 3m\u003c\/strong\u003e is near the threshold of human hearing in a running shower environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eAdjustable Overrun Timer\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eThe \u003cstrong\u003eintegral timer is adjustable from 30 seconds to 30 minutes\u003c\/strong\u003e (factory set at approximately 15 minutes). The overrun period activates when the light switch turns off, continuing to extract residual moisture from the shower enclosure. This satisfies \u003cstrong\u003eApproved Document Part F\u003c\/strong\u003e overrun requirements for intermittent extract systems in bathrooms.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eNo Loft Temperature Extremes\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eLoft-mounted inline fans operate in temperatures ranging from below freezing in winter to over 50°C in summer. Both extremes accelerate motor bearing wear and reduce component life. The SSSFC fan unit sits in the \u003cstrong\u003econditioned airspace of the shower enclosure\u003c\/strong\u003e — a consistent, mild temperature year-round — giving a significantly longer service life than loft-mounted alternatives.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eComplete Kit — Nothing Extra to Buy\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eThe 93086AW ships as a \u003cstrong\u003ecomplete ceiling fitting kit\u003c\/strong\u003e: the fan unit, \u003cstrong\u003e3m flexible ducting\u003c\/strong\u003e, \u003cstrong\u003eexternal grille\u003c\/strong\u003e, and \u003cstrong\u003escrews and rawlplugs\u003c\/strong\u003e. The fan sits flush in the shower ceiling void, ducting connects to the external grille through the ceiling and loft space, requiring no additional components for a standard installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"flex:1;min-width:255px;border:1px solid #ddd;border-radius:6px;padding:16px;border-top:3px solid #008377;\"\u003e\n    \u003cstrong style=\"color:#008377;\"\u003eMade in Britain, Part F Compliant\u003c\/strong\u003e\n    \u003cp style=\"margin:8px 0 0;\"\u003eManufactured in the UK under \u003cstrong\u003eISO 9001\u003c\/strong\u003e quality management. The 21 l\/s high-speed extract performance meets \u003cstrong\u003eApproved Document Part F\u003c\/strong\u003e requirements for bathrooms and shower rooms. The \u003cstrong\u003eEAN 5013562930864\u003c\/strong\u003e confirms the 93086AW kit code. Xpelair's \u003cstrong\u003e2-year UK manufacturer guarantee\u003c\/strong\u003e covers all components.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- WHAT'S IN THE BOX --\u003e\n\u003ch3 style=\"color:#008377;border-bottom:2px solid #008377;padding-bottom:6px;\"\u003eKit Contents\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background:#008377;color:#fff;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eItem\u003c\/td\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eDetails\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eSimply Silent DX100BTR Fan Unit\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e2-speed, timer, round grille fascia, 230V mains\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003eFlexible Ducting\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e3m × 100mm PVC flexible hose\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eExternal Grille\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eWhite square external wall\/roof outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;\"\u003eFixings\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eScrews and rawlplugs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;\"\u003eInstructions\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eInstallation and maintenance manual\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- SPEC TABLE --\u003e\n\u003ch3 style=\"color:#008377;border-bottom:2px solid #008377;padding-bottom:6px;margin-top:24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background:#008377;color:#fff;\"\u003e\u003ctd colspan=\"2\" style=\"padding:8px;font-weight:bold;\"\u003eFan Performance\u003c\/td\u003e\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;width:40%;\"\u003eMPN \/ Kit Code\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e93086AW (SSSFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e5013562930864\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eFan Unit Inside Kit\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eSimply Silent DX100BTR\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eSpeeds\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e2 (selectable at installation)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eExtract Rate — Low Speed\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e15 l\/s \/ 54 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eExtract Rate — High Speed\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e21 l\/s \/ 76 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eSound Level — Low Speed @ 3m\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e22 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eSound Level — High Speed @ 3m\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e34 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eElectrical Power\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e6.0W (low) \/ 6.7W (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eIPX4 (Zone 1 with 30mA RCD; Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eMotor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eAC (mains voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e230V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eMax Fuse Rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#008377;color:#fff;\"\u003e\u003ctd colspan=\"2\" style=\"padding:8px;font-weight:bold;\"\u003eTimer\u003c\/td\u003e\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eTimer Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e30 seconds – 30 minutes (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eWiring Cores Required\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e3-core (L, N, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#008377;color:#fff;\"\u003e\u003ctd colspan=\"2\" style=\"padding:8px;font-weight:bold;\"\u003ePhysical\u003c\/td\u003e\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eFan Unit Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e178 × 178 × 35mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eDuct Diameter\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e100mm (4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eFascia Style\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eRound grille, cool white\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eCeiling (in-shower)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eBuilding Regs Part F; ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f2f2f2;\"\u003e\n\u003ctd style=\"padding:8px;font-weight:bold;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:8px;\"\u003e2 years (Xpelair UK)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch3 style=\"color:#008377;border-bottom:2px solid #008377;padding-bottom:6px;margin-top:28px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cdetails style=\"border:1px solid #ddd;border-radius:4px;margin:8px 0;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:10px 14px;cursor:pointer;font-weight:bold;border-radius:4px;\"\u003eWhy is an in-shower fan better than a wall-mounted bathroom fan?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:12px 16px;\"\u003e\u003cp\u003eA conventional wall or ceiling fan draws humid air across the room before extracting it. Steam from a shower can reach cold mirrors, walls and windows during this transit, causing condensation. The SSSFC installs \u003cstrong\u003edirectly within the shower ceiling\u003c\/strong\u003e, capturing steam at source before it can spread. Measured installed extraction is \u003cstrong\u003e88% better\u003c\/strong\u003e than a comparable inline fan drawing through the same duct run — because the air has no room to disperse before extraction begins.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #ddd;border-radius:4px;margin:8px 0;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:10px 14px;cursor:pointer;font-weight:bold;border-radius:4px;\"\u003eDoes this fan need an RCD? Can it be installed directly above a shower?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:12px 16px;\"\u003e\u003cp\u003eYes to both. The 93086AW operates at \u003cstrong\u003e230V mains voltage\u003c\/strong\u003e and is rated \u003cstrong\u003eIPX4\u003c\/strong\u003e, which allows Zone 1 installation (directly above the shower tray) provided the circuit is \u003cstrong\u003eprotected by a 30mA RCD\u003c\/strong\u003e as required by \u003cstrong\u003eBS 7671\u003c\/strong\u003e. If your installation cannot include RCD protection, the \u003cstrong\u003eIllumi (93087AW)\u003c\/strong\u003e uses a \u003cstrong\u003e12V SELV system\u003c\/strong\u003e with transformer, which does not require an RCD for Zone 1 installation.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #ddd;border-radius:4px;margin:8px 0;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:10px 14px;cursor:pointer;font-weight:bold;border-radius:4px;\"\u003eHow is the fan connected to the light switch?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:12px 16px;\"\u003e\u003cp\u003eThe SSSFC is wired via a \u003cstrong\u003e3-core cable (L, N, T)\u003c\/strong\u003e. The Live and Neutral connect to the permanent supply; the Timer terminal (T) connects to the \u003cstrong\u003eswitched live from the room light switch\u003c\/strong\u003e. When the light turns on, the fan starts. When the light turns off, the fan continues to run for the set overrun period, then stops automatically. A \u003cstrong\u003edouble-pole isolating switch\u003c\/strong\u003e should be incorporated in the fixed wiring.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #ddd;border-radius:4px;margin:8px 0;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:10px 14px;cursor:pointer;font-weight:bold;border-radius:4px;\"\u003eCan the 3m ducting supplied reach from the shower ceiling to the external wall?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:12px 16px;\"\u003e\u003cp\u003eFor most domestic bathrooms where the shower is on a ground or upper floor with a loft above, the 3m supplied is sufficient for the run from the fan to the external grille via the ceiling void. For larger properties or longer runs, the supplied ducting can be extended with a \u003cstrong\u003e100mm in-line duct connector\u003c\/strong\u003e and additional flexible or rigid duct. However, remember that \u003cstrong\u003eeach extra metre of duct reduces airflow\u003c\/strong\u003e — keep runs as short and straight as possible for maximum extraction performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"border:1px solid #ddd;border-radius:4px;margin:8px 0;\"\u003e\n  \u003csummary style=\"background:#008377;color:#fff;padding:10px 14px;cursor:pointer;font-weight:bold;border-radius:4px;\"\u003eWhat is the difference between the 93086AW and the 93087AW Illumi?\u003c\/summary\u003e\n  \u003cdiv style=\"padding:12px 16px;\"\u003e\u003cp\u003eBoth kits use Ghost technology and the same in-shower ceiling mounting approach. The \u003cstrong\u003e93087AW Illumi\u003c\/strong\u003e adds a \u003cstrong\u003ebuilt-in warm white LED light (207 lumens)\u003c\/strong\u003e powered via an included \u003cstrong\u003e12V SELV transformer\u003c\/strong\u003e — making it simultaneously a shower light and extractor fan. The SELV system also removes the RCD requirement for Zone 1, since the in-shower components operate at safe extra-low voltage. Choose the \u003cstrong\u003e93086AW\u003c\/strong\u003e for straightforward fan-only extraction; choose the \u003cstrong\u003e93087AW\u003c\/strong\u003e if you also want integrated shower lighting or prefer a SELV installation.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003c\/div\u003e","brand":"Xpelair","offers":[{"title":"Default Title","offer_id":64930187313501,"sku":"93086AW","price":53.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/simply-silent-shower-timer-fan-kit-93086AW.jpg?v=1780997706","url":"https:\/\/qualityheating.co.uk\/products\/xpelair-simply-silent-shower-fan-complete-sssfc-100mm-timer-93086aw","provider":"AIZO Quality Heating","version":"1.0","type":"link"}