{"product_id":"viessmann-vitotrol-100-e-modulating-room-control-7968153","title":"Viessmann Vitotrol 100-E Modulating Room Control | 7968153","description":"\u003c!-- SEO Product Name: Viessmann Vitotrol 100-E Modulating Room Control | 7968153 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThe \u003cstrong\u003eViessmann Vitotrol 100-E\u003c\/strong\u003e is a wall-mounted, wireless room load compensator that manages heating and hot water via \u003cstrong\u003etwo-way radio communication\u003c\/strong\u003e with the boiler — not a conventional on\/off room thermostat, but a device that actively \u003cstrong\u003emodulates the boiler's output\u003c\/strong\u003e to match real room demand.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eCommunicating over Viessmann's \u003cstrong\u003eOne Base protocol\u003c\/strong\u003e, the Vitotrol 100-E lets the boiler ramp its heat output up or down smoothly rather than simply switching on and off, improving both comfort and running efficiency without the need for an outdoor temperature sensor.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px 24px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003eModulating\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eControl type\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003e2.4 GHz\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eEncrypted radio band\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003e3\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eRoom temp setpoints\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eHeating circuit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003e\u003cspan style=\"color:#008377CF;\"\u003eErP 5\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eEfficiency level\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; min-width:120px; background:#F7FAFA; border:1px solid #D9EDEA; border-top:3px solid #008377CF; border-radius:6px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:800; color:#00625D;\"\u003e\u003cspan style=\"color:#008377CF;\"\u003eBoiler Plus\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; color:#5A5A5A; margin-top:4px; line-height:1.3;\"\u003eCompliant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; border-radius:4px; padding:14px 16px; margin:0 0 20px 0; display:flex; align-items:flex-start; gap:10px;\"\u003e\n\u003cspan style=\"font-size:18px; line-height:1;\"\u003e🛈\u003c\/span\u003e\u003cdiv style=\"font-size:15px; color:#2B2B2B; line-height:1.55;\"\u003e\n\u003cstrong style=\"color:#E0942A;\"\u003ePlease Note:\u003c\/strong\u003e The Vitotrol 100-E is designed for \u003cstrong\u003esystem boiler (4-pipe configuration) installations\u003c\/strong\u003e and is not intended for use on S-plan or Y-plan systems. It must not be combined with weather compensation on the same heating circuit — choose one control strategy or the other.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -6px 24px -6px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eTwo-way boiler communication\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eEncrypted \u003cstrong\u003e2.4 GHz low-power radio\u003c\/strong\u003e link between the Vitotrol 100-E and the boiler allows genuine two-way data exchange, not just a one-way demand signal.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eOutput modulation, no outdoor sensor\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eBoiler output modulation is achieved through the \u003cstrong\u003eOne Base protocol\u003c\/strong\u003e alone — no separate outdoor temperature sensor is required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eMeets Boiler Plus requirements\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eSatisfies UK \u003cstrong\u003eBoiler Plus\u003c\/strong\u003e load compensation requirements for new gas boiler installations without additional third-party controls.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eDHW temperature regulation\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eBeyond space heating, the unit also provides \u003cstrong\u003edomestic hot water temperature control\u003c\/strong\u003e for systems with a compatible cylinder.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eIlluminated display with fault indication\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eShows room temperature, time and operating state, and will display a \u003cstrong\u003eboiler fault code directly\u003c\/strong\u003e on the thermostat screen.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; min-width:240px; background:#FFFFFF; border:1px solid #D9EDEA; border-radius:8px; padding:16px; margin:6px;\"\u003e\n\u003cdiv style=\"font-size:15.5px; font-weight:700; color:#00625D; margin-bottom:6px;\"\u003eFactory-fitted receiver, no extra wiring\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#3A3A3A; line-height:1.55;\"\u003eNo additional receiver unit is needed — the receiver is \u003cstrong\u003efactory fitted inside the boiler\u003c\/strong\u003e, keeping installation simple.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; color:#00625D; margin:32px 0 14px 0; padding-bottom:8px; border-bottom:2px solid #008377CF;\"\u003eSpecification\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13.5px; letter-spacing:.04em; text-transform:uppercase; padding:9px 14px; border-radius:6px 6px 0 0; margin-top:14px;\"\u003eControl Function\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 6px 6px; overflow:hidden; margin-bottom:6px;\"\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eType\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eWireless room load compensator (modulating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eCommunication protocol\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eOne Base (encrypted 2.4 GHz low-power radio)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eHeating circuits supported\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003e1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eDHW control\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eYes — 1 hot water temperature setpoint\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eRoom temperature setpoints\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eUp to 3 (Reduced, Normal, Comfort)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eTime programs\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eDaily and weekly programs for heating and DHW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13.5px; letter-spacing:.04em; text-transform:uppercase; padding:9px 14px; border-radius:6px 6px 0 0; margin-top:14px;\"\u003eCompatibility\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 6px 6px; overflow:hidden; margin-bottom:6px;\"\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eSystem type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eSystem boiler, 4-pipe configuration\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eNot suitable for\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eS-plan or Y-plan systems\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eWeather compensation\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eNot to be used in conjunction with weather compensation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eApp integration\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eFully compatible with the Viessmann ViCare app\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:13.5px; letter-spacing:.04em; text-transform:uppercase; padding:9px 14px; border-radius:6px 6px 0 0; margin-top:14px;\"\u003eCompliance \u0026amp; Features\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-top:none; border-radius:0 0 6px 6px; overflow:hidden; margin-bottom:6px;\"\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eBoiler Plus\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eMeets UK Boiler Plus load compensation requirement\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eSoftware updates\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eSupports automatic over-the-air updates via the boiler's internet connection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eFault indication\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eBoiler fault codes shown directly on the Vitotrol display\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 14px; font-weight:600; font-size:14px; color:#333333;\"\u003eInstallation\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 14px; font-size:14px; color:#222222;\"\u003eWall-mounted, battery powered, no additional receiver required\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"padding:13px 16px; font-size:15px; font-weight:700; color:#00625D; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#E6F4F3;\"\u003e\u003cspan\u003eIs the Vitotrol 100-E a standard on\/off thermostat?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377CF\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:13px 16px 15px 16px; font-size:14.5px; color:#3A3A3A; line-height:1.6; border-top:1px solid #D9EDEA; background:#FFFFFF;\"\u003eNo. It's described by Viessmann specifically as not an on\/off room thermostat — it works as a load compensator, modulating the boiler's output via the One Base protocol rather than simply switching the burner on and off.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"padding:13px 16px; font-size:15px; font-weight:700; color:#00625D; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#E6F4F3;\"\u003e\u003cspan\u003eCan I use the Vitotrol 100-E with an S-plan or Y-plan heating system?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377CF\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:13px 16px 15px 16px; font-size:14.5px; color:#3A3A3A; line-height:1.6; border-top:1px solid #D9EDEA; background:#FFFFFF;\"\u003eNo. Viessmann specifies this control for system boiler, 4-pipe configuration installations only — it is not intended for S-plan or Y-plan setups.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"padding:13px 16px; font-size:15px; font-weight:700; color:#00625D; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#E6F4F3;\"\u003e\u003cspan\u003eDo I still need an outdoor temperature sensor with this control?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377CF\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:13px 16px 15px 16px; font-size:14.5px; color:#3A3A3A; line-height:1.6; border-top:1px solid #D9EDEA; background:#FFFFFF;\"\u003eNo. Boiler output modulation is handled through the One Base communication protocol between the Vitotrol 100-E and the boiler, so a separate outdoor sensor for weather compensation isn't required — and the two shouldn't be combined on the same circuit.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"padding:13px 16px; font-size:15px; font-weight:700; color:#00625D; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#E6F4F3;\"\u003e\u003cspan\u003eDoes this control meet Boiler Plus requirements?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377CF\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:13px 16px 15px 16px; font-size:14.5px; color:#3A3A3A; line-height:1.6; border-top:1px solid #D9EDEA; background:#FFFFFF;\"\u003eYes, the Vitotrol 100-E provides load-compensated control that satisfies the UK Boiler Plus requirement for new boiler installations.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:8px; overflow:hidden;\"\u003e\u003csummary style=\"padding:13px 16px; font-size:15px; font-weight:700; color:#00625D; cursor:pointer; list-style:none; display:flex; align-items:center; justify-content:space-between; background:#E6F4F3;\"\u003e\u003cspan\u003eWhat happens if the boiler develops a fault?\u003c\/span\u003e\u003csvg width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#008377CF\" stroke-width=\"2.5\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:13px 16px 15px 16px; font-size:14.5px; color:#3A3A3A; line-height:1.6; border-top:1px solid #D9EDEA; background:#FFFFFF;\"\u003eBoiler fault indication is shown directly on the Vitotrol 100-E's illuminated display, so faults can be identified from the room without going to the boiler itself.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Viessmann","offers":[{"title":"Default Title","offer_id":65934960296285,"sku":"7968153","price":175.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ViessmannVitotrol100-EModulatingRoomControl7968153.jpg?v=1789543275","url":"https:\/\/qualityheating.co.uk\/products\/viessmann-vitotrol-100-e-modulating-room-control-7968153","provider":"AIZO Quality Heating","version":"1.0","type":"link"}