{"product_id":"vaillant-ecolevel-230v-condensate-pump-20030797-4m-head","title":"Vaillant ecoLEVEL 230V Condensate Pump | 20030797 | 4m Head","description":"\u003cdiv style=\"font-size: 16px; max-width: 900px; font-family: Arial, Helvetica, sans-serif; color: #222; line-height: 1.55;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eVaillant ecoLEVEL condensate pump\u003c\/strong\u003e provides a dependable solution for removing \u003cstrong\u003econdensate\u003c\/strong\u003e from \u003cstrong\u003eVaillant condensing boilers\u003c\/strong\u003e and compatible \u003cstrong\u003eecoPOWER 1.0\u003c\/strong\u003e systems where gravity drainage is impractical. Its compact \u003cstrong\u003ewall mounted\u003c\/strong\u003e design, \u003cstrong\u003e4 m maximum pump head\u003c\/strong\u003e and \u003cstrong\u003eautomatic operation\u003c\/strong\u003e make it especially useful for basement, utility room and awkward boiler locations.\u003c\/p\u003e\n\u003cp\u003eDesigned for individual appliances up to \u003cstrong\u003e45 kW\u003c\/strong\u003e, the ecoLEVEL continuously monitors the condensate level and starts automatically when required. A built in \u003cstrong\u003esafety overflow switch\u003c\/strong\u003e can shut the boiler down if a fault prevents condensate from being discharged, helping to protect the heating system from overflow damage.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 18px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e4 m\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eMaximum pump head\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e150 l\/h\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eDelivery at 4 m head\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e0.5 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eCondensate capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e230 V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eMains voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e45 kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eMaximum appliance rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; min-width: 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px;\"\u003eIP44\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eIngress protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 5px solid #d9534f; background: #fdf3f2; padding: 12px 14px; border-radius: 6px; margin: 16px 0;\"\u003e\n\u003cstrong style=\"color: #d9534f;\"\u003eSafety and installation notice:\u003c\/strong\u003e Installation, electrical connection, commissioning, inspection and repair must be carried out by a \u003cstrong\u003ecompetent person\u003c\/strong\u003e in accordance with applicable UK regulations. Isolate the pump and boiler before any maintenance work.\u003c\/div\u003e\n\u003cdiv style=\"border-left: 5px solid #f0ad4e; background: #fffaf0; padding: 12px 14px; border-radius: 6px; margin: 16px 0;\"\u003e\n\u003cstrong style=\"color: #b26b00;\"\u003eCompatibility note:\u003c\/strong\u003e The \u003cstrong\u003eecoLEVEL\u003c\/strong\u003e is intended for use with \u003cstrong\u003eVaillant condensing boilers\u003c\/strong\u003e and the \u003cstrong\u003eecoPOWER 1.0\u003c\/strong\u003e CHP system, for individual units up to \u003cstrong\u003e45 kW\u003c\/strong\u003e. It is not suitable for wastewater, chemicals, oil containing emulsions or other non condensate fluids.\u003c\/div\u003e\n\u003cdiv style=\"border-left: 5px solid #008377CF; background: #f2faf8; padding: 12px 14px; border-radius: 6px; margin: 16px 0;\"\u003e\n\u003cstrong style=\"color: #008377cf;\"\u003eUseful information:\u003c\/strong\u003e The pump is self regulating once installed. Two front mounted \u003cstrong\u003eLED indicators\u003c\/strong\u003e show power status, pumping activity and fault conditions, while the supplied \u003cstrong\u003esafety cut out connection\u003c\/strong\u003e supports boiler shutdown or an external alarm where fitted.\u003c\/div\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 26px 0 14px;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px;\"\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eAutomatic Condensate Removal\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eThe pump continuously checks the water level and starts automatically at the maximum fill level, providing reliable \u003cstrong\u003ehands free condensate disposal\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eUp to 4 m Vertical Lift\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eWith a maximum \u003cstrong\u003e4 m feed height\u003c\/strong\u003e and up to \u003cstrong\u003e150 litres per hour\u003c\/strong\u003e delivery at full head, it suits installations where the drain point is above the boiler.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eCompact Wall-Mounted Design\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eThe space saving \u003cstrong\u003e150 x 175 x 100 mm\u003c\/strong\u003e housing mounts neatly on a wall close to the boiler, making it suitable for confined plant rooms and utility spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eSafety Overflow Protection\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eThe integrated \u003cstrong\u003esafety cut out switch\u003c\/strong\u003e can stop the boiler if the condensate level remains too high, helping to reduce the risk of leakage and system damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eClear Status Indication\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eTwo \u003cstrong\u003eLED status lights\u003c\/strong\u003e provide at a glance confirmation of readiness, pumping operation and fault conditions for straightforward commissioning and diagnostics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; min-width: 270px; border: 1px solid #008377CF; border-top: 4px solid #008377CF; border-radius: 8px; padding: 14px;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003eComplete Installation Kit\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eSupplied with a \u003cstrong\u003ewall bracket\u003c\/strong\u003e, fixings, \u003cstrong\u003e6 m drain hose\u003c\/strong\u003e, inlet hose, condensate angle and documentation to support a tidy, professional installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 26px 0 14px;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #008377CF; border-radius: 8px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px;\"\u003eGeneral\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eVaillant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eProduct range\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eecoLEVEL\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e\u003cspan\u003e20030797\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eCondensate removal from heating installations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px;\"\u003ePerformance\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e0.5 litres\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMaximum pump head\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e4 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMaximum delivery\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e150 litres per hour at 4 m head\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eApproved appliance rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eIndividual units up to 45 kW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e230 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e50 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMaximum current consumption\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e1 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMaximum power rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e25 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eSafety cut-out switch\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e5 mA to 4 A, 230 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eIP44 to EN 60529\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px;\"\u003eDimensions and Installation\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eDimensions (H x W x L)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e150 x 175 x 100 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e1.8 kg filled\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eWall mounted\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eAmbient temperature range\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e5 °C to 60 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eDrain hose supplied\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003e10 mm diameter x 6 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 10px 14px;\"\u003eCertification and Compliance\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eCE marking\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eYes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; border-bottom: 1px solid #008377CF;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eRelevant standards\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eEN 60335-1, EN 60335-2-41, EN 55014-1, EN 55014-2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex;\"\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px; background: #f7fbfa;\"\u003e\u003cstrong\u003eMaintenance recommendation\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; padding: 9px 14px;\"\u003eAt least annually, alongside boiler maintenance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 20px; border-bottom: 3px solid #008377CF; padding-bottom: 6px; margin: 26px 0 14px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eWhich boilers is the Vaillant ecoLEVEL suitable for?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eIt is designed for use with \u003cstrong\u003eVaillant condensing boilers\u003c\/strong\u003e and the \u003cstrong\u003eecoPOWER 1.0\u003c\/strong\u003e CHP system, for individual appliances up to \u003cstrong\u003e45 kW\u003c\/strong\u003e. Always follow the boiler and pump installation instructions during specification and fitting.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eHow high can the ecoLEVEL pump condensate?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eThe pump can lift condensate to a maximum vertical height of \u003cstrong\u003e4 m\u003c\/strong\u003e. At this maximum head, it can deliver up to \u003cstrong\u003e150 litres per hour\u003c\/strong\u003e, provided the discharge hose is routed correctly with a downward gradient to the drain point.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eDoes the pump operate automatically?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eYes. Once installed and connected, the ecoLEVEL operates automatically by monitoring the condensate level and starting when the highest permitted level is reached. Its \u003cstrong\u003eself-regulating operation\u003c\/strong\u003e requires no routine manual control.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eWhat happens if the pump develops a fault?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eIf condensate cannot be discharged, the \u003cstrong\u003ered LED\u003c\/strong\u003e indicates a high water level and the \u003cstrong\u003esafety cut out switch\u003c\/strong\u003e can trigger. Where connected to the boiler, this can shut the appliance down to help prevent further condensate production and overflow.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eCan the ecoLEVEL pump wastewater or other liquids?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eNo. It is intended only for \u003cstrong\u003econdensate from heating installations\u003c\/strong\u003e. It must not be used for wastewater, chemicals, oil containing emulsions, solid media or flammable liquids.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; padding: 12px 14px; cursor: pointer;\"\u003eHow often should the pump be maintained?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px;\"\u003eVaillant recommends inspection and maintenance at least \u003cstrong\u003eonce a year\u003c\/strong\u003e, ideally alongside the boiler service. Maintenance should include checking hoses, cleaning the \u003cstrong\u003enon return valve\u003c\/strong\u003e and inspecting the condensate vessel for contamination.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Vaillant","offers":[{"title":"Default Title","offer_id":67661662421382,"sku":"20030797","price":199.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Vaillant_ecoLEVEL_230V_Condensate_Pump_1.jpg?v=1792491958","url":"https:\/\/qualityheating.co.uk\/products\/vaillant-ecolevel-230v-condensate-pump-20030797-4m-head","provider":"AIZO Quality Heating","version":"1.0","type":"link"}