{"product_id":"vaillant-dn-60-white-plume-management-kit-0010039340-pp-flue-kit","title":"Vaillant DN 60 White Plume Management Kit | 0010039340 | PP Flue Kit","description":"\u003cdiv style=\"font-size: 16px; max-width: 900px; font-family: Arial, Helvetica, sans-serif; color: #222; line-height: 1.6;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eVaillant White Plume Management Kit\u003c\/strong\u003e is a purpose designed \u003cstrong\u003eboiler flue accessory\u003c\/strong\u003e that helps redirect the visible \u003cstrong\u003econdensing boiler plume\u003c\/strong\u003e away from windows, doors, neighbouring boundaries and other sensitive areas. Manufactured in durable \u003cstrong\u003epolypropylene (PP)\u003c\/strong\u003e with a clean \u003cstrong\u003ewhite finish\u003c\/strong\u003e, this \u003cstrong\u003eDN 60 \/ 60 mm\u003c\/strong\u003e kit supports a tidy, professional flue installation for compatible Vaillant condensing boilers.\u003c\/p\u003e\n\u003cp\u003eIts \u003cstrong\u003etelescopic, push-fit design\u003c\/strong\u003e makes positioning and installation straightforward for heating engineers, while helping installations meet the practical requirements for safe and considerate flue gas discharge.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px; margin: 20px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003eDN 60\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eFlue diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003e1030 mm\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eLength\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003ePP\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003ePolypropylene build\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003eWhite\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eExterior finish\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003e0010039340\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eManufacturer part number\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 130px; border: 2px solid #008377CF; border-radius: 8px; padding: 12px; text-align: center; background: #f7fbfa;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; font-size: 18px;\"\u003e\u003cstrong\u003e1 Year\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px;\"\u003eManufacturer warranty*\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #008377CF; background: #f2faf8; padding: 14px 16px; border-radius: 6px; margin: 18px 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eUseful information:\u003c\/strong\u003e This \u003cstrong\u003eplume management kit\u003c\/strong\u003e is intended for use with compatible \u003cstrong\u003eVaillant condensing boilers\u003c\/strong\u003e. Always confirm the boiler model, flue configuration and installation requirements before ordering or fitting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #d97706; background: #fff8ec; padding: 14px 16px; border-radius: 6px; margin: 18px 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eCompatibility note:\u003c\/strong\u003e Flue systems vary by boiler model and installation layout. The \u003cstrong\u003eDN 60 diameter\u003c\/strong\u003e, flue route, permitted lengths and termination position must be checked against the boiler manufacturer’s installation instructions before purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left: 6px solid #dc2626; background: #fef2f2; padding: 14px 16px; border-radius: 6px; margin: 18px 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003eSafety and installation:\u003c\/strong\u003e Flue work should be carried out by a competent, \u003cstrong\u003eGas Safe registered engineer\u003c\/strong\u003e in accordance with the boiler manufacturer’s instructions and applicable UK building regulations. Incorrect flue termination or unsupported pipework can affect safe operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 26px 0 10px; color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 12px;\"\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003eEffective Plume Control\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eHelps guide the \u003cstrong\u003eboiler condensate plume\u003c\/strong\u003e away from doors, windows and neighbouring properties, supporting a more considerate installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003eDurable Polypropylene\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eConstructed from \u003cstrong\u003eweather resistant polypropylene (PP)\u003c\/strong\u003e, chosen for its suitability in external boiler flue applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003eDN 60 \/ 60 mm System\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eDesigned around a \u003cstrong\u003e60 mm flue diameter\u003c\/strong\u003e, making it suitable for compatible Vaillant flue installations that require this size.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003eTelescopic Adjustment\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eThe \u003cstrong\u003etelescopic design\u003c\/strong\u003e allows installers to adjust the arrangement on site, helping reduce the need to cut pipework to length.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003ePush-Fit Installation\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cstrong\u003ePush-fit connections\u003c\/strong\u003e support a quicker, cleaner installation compared with more involved flue arrangements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 270px; border: 1px solid #008377CF; border-top: 5px solid #008377CF; border-radius: 8px; padding: 14px; background: #ffffff;\"\u003e\n\u003cdiv style=\"color: #008377cf; font-weight: bold; margin-bottom: 6px;\"\u003e\u003cstrong\u003eDiscreet White Finish\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0;\"\u003eThe \u003cstrong\u003ewhite exterior\u003c\/strong\u003e blends neatly with most property exteriors, helping the completed installation look tidy and unobtrusive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 28px 0 10px; color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"border: 2px solid #008377CF; border-radius: 8px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; padding: 10px 14px; font-weight: bold;\"\u003e\u003cstrong\u003eProduct Identification\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eVaillant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003ePlume management kit \/ boiler flue accessory\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eMPN\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e0010039340\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e4024074938935\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; padding: 10px 14px; font-weight: bold;\"\u003e\u003cstrong\u003eDimensions and Material\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eFlue diameter\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eDN 60 \/ 60 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e1030 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003ePolypropylene (PP)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eWhite\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; padding: 10px 14px; font-weight: bold;\"\u003e\u003cstrong\u003eCompatibility and Installation\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eSuitable use\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eCompatible Vaillant condensing boiler installations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eConnection type\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003ePush-fit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px; border-bottom: 1px solid #d9e8e5;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eTelescopic\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #f4faf8; padding: 10px 14px;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eProduct range\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003eVaillant Domestic Flues and Flue Accessories\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; padding: 10px 14px; font-weight: bold;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #ffffff; padding: 10px 14px;\"\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e1 year, subject to the manufacturer’s terms and conditions*\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #555; margin-top: 10px;\"\u003e*Warranty terms, registration requirements and exclusions are set by the manufacturer and may depend on correct installation and use.\u003c\/p\u003e\n\u003cdiv style=\"margin: 28px 0 10px; color: #008377cf; font-weight: bold; font-size: 20px;\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; padding: 12px 14px; font-weight: bold; cursor: pointer;\"\u003e\u003cstrong\u003eWhat does a plume management kit do?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; background: #ffffff;\"\u003eA \u003cstrong\u003eplume management kit\u003c\/strong\u003e redirects the visible steam like plume produced by a \u003cstrong\u003econdensing boiler\u003c\/strong\u003e, helping prevent it from blowing towards windows, doors, walkways or neighbouring properties.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; padding: 12px 14px; font-weight: bold; cursor: pointer;\"\u003e\u003cstrong\u003eIs this kit compatible with all Vaillant boilers?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; background: #ffffff;\"\u003eIt is intended for \u003cstrong\u003ecompatible Vaillant condensing boilers\u003c\/strong\u003e, but compatibility depends on the boiler model and its flue system. Always check the required \u003cstrong\u003eDN 60 \/ 60 mm\u003c\/strong\u003e flue configuration and manufacturer installation instructions before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; padding: 12px 14px; font-weight: bold; cursor: pointer;\"\u003e\u003cstrong\u003eCan I install the plume kit myself?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; background: #ffffff;\"\u003eBoiler flue work should be completed by a \u003cstrong\u003ecompetent, Gas Safe registered engineer\u003c\/strong\u003e. Correct positioning, support and termination are essential for safe operation and compliance with applicable UK requirements.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; padding: 12px 14px; font-weight: bold; cursor: pointer;\"\u003e\u003cstrong\u003eWhat material is the kit made from?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; background: #ffffff;\"\u003eThe kit is made from \u003cstrong\u003epolypropylene (PP)\u003c\/strong\u003e, a durable material commonly used for external boiler flue components, and is finished in \u003cstrong\u003ewhite\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #008377CF; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; padding: 12px 14px; font-weight: bold; cursor: pointer;\"\u003e\u003cstrong\u003eDoes the telescopic design avoid cutting the flue?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 12px 14px; background: #ffffff;\"\u003eThe \u003cstrong\u003etelescopic, push-fit arrangement\u003c\/strong\u003e can often be adjusted on site, which may remove the need to cut the flue in many installations. Final dimensions must still be checked against the boiler and flue installation instructions.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Vaillant","offers":[{"title":"Default Title","offer_id":67627612438918,"sku":"0010039340","price":119.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Vaillant_DN_60_White_Plume_1.jpg?v=1792056985","url":"https:\/\/qualityheating.co.uk\/products\/vaillant-dn-60-white-plume-management-kit-0010039340-pp-flue-kit","provider":"AIZO Quality Heating","version":"1.0","type":"link"}