{"product_id":"vaillant-arotherm-plus-v2-10kw-12kw-without-interface","title":"Vaillant aroTHERM Plus v2 (10kW \/ 12kW) without Interface","description":"\u003cdiv style=\"font-size:16px; max-width:900px; font-family:Arial, Helvetica, sans-serif; color:#222222; line-height:1.6;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eVaillant aroTHERM plus v2\u003c\/strong\u003e, in the larger \u003cstrong\u003e10kW and 12kW single-phase (230V)\u003c\/strong\u003e outputs, is supplied here \u003cstrong\u003ewithout an interface\u003c\/strong\u003e (heat pump only). These are the highest-output single-phase models in the aroTHERM plus v2 range, suited to larger UK properties with higher heating and hot water demand. Built around the natural refrigerant \u003cstrong\u003eR290\u003c\/strong\u003e, both models deliver flow temperatures of up to \u003cstrong\u003e75°C\u003c\/strong\u003e with a 10-year Global Warming Potential of just \u003cstrong\u003e0.02\u003c\/strong\u003e, backed by Vaillant's new \u003cstrong\u003eFlexible Space Function\u003c\/strong\u003e for reduced installation clearances.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eUp to 75°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003eMax Flow Temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e50 dB(A)\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003eSound Power, A7\/W55\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eR290\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003eNatural Refrigerant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eGWP 0.02\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003e10-Year Global Warming Potential\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e196kg\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003eWeight, Ready for Operation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#ffffff; border-radius:8px; padding:14px 10px; text-align:center;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e230V\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:4px; opacity:0.9;\"\u003eSingle-Phase Supply\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-left:4px solid #008377CF; background:#E6F6F5; padding:12px 16px; margin:16px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px;\"\u003eSame Footprint, Higher Output\u003c\/div\u003e\n\u003cdiv style=\"color:#333333;\"\u003eBoth the 10kW and 12kW single-phase models share identical dimensions (1480mm x 1100mm x 450mm) and weight (196kg), simplifying specification and installation planning across this output pairing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:4px solid #946200; background:#FFF4DE; padding:12px 16px; margin:16px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#946200; margin-bottom:4px;\"\u003eSupplied Without Interface\u003c\/div\u003e\n\u003cdiv style=\"color:#333333;\"\u003eThis listing covers the \u003cstrong\u003eheat pump unit only\u003c\/strong\u003e. A VWZ AI control module, hydraulic module, or uniTOWER pre-plumbed indoor unit must be selected separately depending on the system design.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:4px solid #B3261E; background:#FDECEA; padding:12px 16px; margin:16px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#B3261E; margin-bottom:4px;\"\u003eRCD and Fuse Requirements\u003c\/div\u003e\n\u003cdiv style=\"color:#333333;\"\u003eAll Vaillant heat pumps must be installed with a \u003cstrong\u003eType B RCD\u003c\/strong\u003e rated to 20kHz or greater with a minimum trigger point of 150mA above 1kHz. These 230V models require a \u003cstrong\u003eType C, slow-blow, single-pole switching fuse\u003c\/strong\u003e rated to 25A.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eFlexible Space Function\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eVaillant's new safety concept significantly reduces the protection zone required around the heat pump once activated in the installer settings, providing greater freedom when positioning larger units on site.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eHigh-Output Performance\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eAt 10kW and 12kW, these are the largest single-phase outputs in the aroTHERM plus v2 range, suited to larger homes or properties with higher simultaneous heating and hot water demand.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eHigh Flow Temperatures, Low GWP\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eDelivers flow temperatures of up to \u003cstrong\u003e75°C\u003c\/strong\u003e, while R290's 10-year GWP of just \u003cstrong\u003e0.02\u003c\/strong\u003e makes it significantly more climate-friendly than the traditionally assumed value of 3 often quoted for R290 systems.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eUp to 7-Year Extended Guarantee\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eThe aroTHERM plus v2 comes with an extended guarantee of up to 7 years when registered with a Vaillant cylinder on myREWARDS.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eTwin-Fan Design\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eFitted with two fans (versus one on the 3.5\/5kW models) to move the higher air volume of \u003cstrong\u003e5100m³\/h\u003c\/strong\u003e maximum required at this output, while maintaining a sound power level of 50 dB(A) at A7\/W55 conditions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1; min-width:250px; border:1px solid #e0e0e0; border-radius:8px; padding:16px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:6px;\"\u003eDiscreet Anthracite Casing\u003c\/div\u003e\n\u003cdiv style=\"color:#333333; font-size:14px; line-height:1.5;\"\u003eThe new anthracite casing retains the distinctive look of its award-winning predecessor, blending in perfectly with UK housing stock and suiting retrofit installations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel Variants in This Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0; font-size:14px;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#008377CF; color:#ffffff; padding:8px 12px; text-align:left;\"\u003eOutput\u003c\/th\u003e\n\u003cth style=\"background:#008377CF; color:#ffffff; padding:8px 12px; text-align:left;\"\u003eVaillant Article Number\u003c\/th\u003e\n\u003cth style=\"background:#008377CF; color:#ffffff; padding:8px 12px; text-align:left;\"\u003eRated Current\u003c\/th\u003e\n\u003cth style=\"background:#008377CF; color:#ffffff; padding:8px 12px; text-align:left;\"\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e10kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e8000049517\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e196kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e12kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e8000049518\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e25A\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e196kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0; font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:8px 12px;\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e1480mm x 1100mm x 450mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eWeight, ready for operation\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e196kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eHeating Circuit Connection\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eG 1¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eIPX4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFan Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFan Air Flow, Maximum\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e5100 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:8px 12px;\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e230V (+10%\/-15%), 50Hz, 1~\/N\/PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eRated Current, Maximum\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFuse Size\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFuse Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eCharacteristic C, slow-blow, single-pole switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eRCD Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eType B, rated to 20kHz or greater, min. trigger 150mA above 1kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:8px 12px;\"\u003eHeating Circuit\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eHeating Water Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e20°C to 75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eMinimum \/ Maximum Volume Flow\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e1075 L\/h \/ 2065 L\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eMaximum Static Height Difference (outdoor to highest point)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e13m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eMinimum \/ Maximum Operating Pressure\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e0.5 bar \/ 2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eWater Volume in the Outdoor Unit\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e4.5L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:8px 12px;\"\u003eRefrigerant Circuit\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFluid Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eFluid Fill Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e1.3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eGlobal Warming Potential (GWP), 10-year\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eScroll compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eCompressor Oil Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eSpecific polyalkylene glycol (PAG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:8px 12px;\"\u003eNoise \u0026amp; Efficiency\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eSound Power Level, A7\/W55 (ErP\/outdoor)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003e50 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eEnergy Efficiency Class, 35°C\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eA+++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f4f4f4;\"\u003e\n\u003ctd style=\"padding:8px 12px; font-weight:600; width:45%;\"\u003eEnergy Efficiency Class, 55°C\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;\"\u003eA+++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin:20px 0;\"\u003e\n\u003cdetails style=\"margin-bottom:8px; border:1px solid #e0e0e0; border-radius:6px; overflow:hidden;\"\u003e\n\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat does 'without Interface' mean for this heat pump?\u003c\/summary\u003e\n\u003cdiv style=\"padding:12px 14px; color:#333333; font-size:14px; line-height:1.5;\"\u003eIt means the listing is for the \u003cstrong\u003eoutdoor heat pump unit only\u003c\/strong\u003e. The VWZ AI control module, hydraulic module, or uniTOWER indoor unit must be selected and ordered separately based on the intended system design.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom:8px; border:1px solid #e0e0e0; border-radius:6px; overflow:hidden;\"\u003e\n\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat is the difference between the 10kW and 12kW models?\u003c\/summary\u003e\n\u003cdiv style=\"padding:12px 14px; color:#333333; font-size:14px; line-height:1.5;\"\u003eBoth share identical dimensions, weight, and electrical specification. The key difference is heating output – the 12kW model delivers a higher maximum heating capacity for larger properties or higher-demand installations.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom:8px; border:1px solid #e0e0e0; border-radius:6px; overflow:hidden;\"\u003e\n\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat is the SCOP or efficiency class of these models?\u003c\/summary\u003e\n\u003cdiv style=\"padding:12px 14px; color:#333333; font-size:14px; line-height:1.5;\"\u003eBoth models are rated \u003cstrong\u003eA+++\u003c\/strong\u003e at 35°C flow and 55°C flow, the highest energy efficiency class available for heat pumps of this type.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom:8px; border:1px solid #e0e0e0; border-radius:6px; overflow:hidden;\"\u003e\n\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat size property is the 10kW\/12kW range suited to?\u003c\/summary\u003e\n\u003cdiv style=\"padding:12px 14px; color:#333333; font-size:14px; line-height:1.5;\"\u003eThese are the largest single-phase outputs in the aroTHERM plus v2 range, generally suited to larger UK homes or properties with higher simultaneous heating and hot water demand. An accurate heat loss calculation for the specific property should confirm the correct output.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom:8px; border:1px solid #e0e0e0; border-radius:6px; overflow:hidden;\"\u003e\n\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; font-weight:600; cursor:pointer; list-style:none;\"\u003eIs a three-phase version of these outputs available?\u003c\/summary\u003e\n\u003cdiv style=\"padding:12px 14px; color:#333333; font-size:14px; line-height:1.5;\"\u003eYes. Vaillant also offer \u003cstrong\u003e400V three-phase versions\u003c\/strong\u003e of the 10kW and 12kW aroTHERM plus v2 models for properties with a three-phase electrical supply or where the local DNO requires it.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vaillant","offers":[{"title":"10kW 1-PH","offer_id":65281280213341,"sku":"8000049517","price":6200.0,"currency_code":"GBP","in_stock":true},{"title":"12kW 1-PH","offer_id":65281280246109,"sku":"8000049518","price":6990.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/VaillantaroTHERMPlusv210kW.jpg?v=1784288950","url":"https:\/\/qualityheating.co.uk\/products\/vaillant-arotherm-plus-v2-10kw-12kw-without-interface","provider":"AIZO Quality Heating","version":"1.0","type":"link"}