{"product_id":"thermox-dtx-non-toxic-ethylene-glycol-antifreeze-heat-transfer-fluid-25-litre-gshp-ashp-ground-air-water-heat-pump-systems","title":"Thermox DTX Non-Toxic Ethylene Glycol Antifreeze Heat Transfer Fluid 25 Litre — GSHP ASHP Ground Air Water Heat Pump Systems","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    \u003cstrong\u003eThermox DTX\u003c\/strong\u003e is a \u003cstrong\u003enon-toxic ethylene glycol heat transfer fluid\u003c\/strong\u003e specifically formulated for ground source, air source, and water source heat pump systems. It combines the \u003cstrong\u003esuperior heat transfer performance of ethylene glycol\u003c\/strong\u003e — better thermal conductivity, lower viscosity, and less volume needed per degree of freeze protection compared to propylene glycol — with full \u003cstrong\u003enon-toxic classification\u003c\/strong\u003e, achieved through Hydratech's patented \u003cstrong\u003eDeTox™ additive\u003c\/strong\u003e. ASTM D1384 and BS6580 corrosion-inhibited. Frost protection down to \u003cstrong\u003e–50°C depending on concentration\u003c\/strong\u003e. Supplied as a \u003cstrong\u003e25 litre container of concentrate\u003c\/strong\u003e, sufficient to prepare approximately 100 litres of mixed system fluid at a typical heat pump operating concentration. Midsummer's shipments are \u003cstrong\u003etinted green\u003c\/strong\u003e for easy identification of mixed fluid in the system.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e–50°C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eFrost protection (at 54.3%)\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eNon-toxic\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eDeTox™ patented additive\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e25 L\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eConcentrate — ~100L mixed\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003eASTM D1384\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eCorrosion tested\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:20px;font-weight:700;\"\u003e3 years\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eShelf life (sealed)\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── TEAL APPLICATION CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #008377CF;background:#e6f4f3;padding:10px 16px;margin-bottom:14px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ Minimum dose: 22% — Recommended use with deionised water\u003c\/strong\u003e\u003cbr\u003e\n    The minimum concentration of Thermox DTX should be \u003cstrong\u003eno less than 22% of system volume\u003c\/strong\u003e (for protection to –10°C); maximum concentration does not normally exceed 60%. Hydratech recommends dilution using \u003cstrong\u003edeionised, distilled or UltraPure™ water\u003c\/strong\u003e — avoid water with high calcium salt or chloride content. Use a \u003cstrong\u003erecently calibrated refractometer\u003c\/strong\u003e to verify concentration in the mixed fluid before commissioning. As per BSRIA guide BG 29\/2012, all pipework should be clean and free from contamination before filling.\n  \u003c\/div\u003e\n\n  \u003c!-- ── AMBER SAFETY NOTE ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #f59e0b;background:#fff8e1;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#b45309;\"\u003e⚡ Safety Data Sheet required before handling\u003c\/strong\u003e\u003cbr\u003e\n    Although classified as non-toxic, Thermox DTX is a chemical product. The Safety Data Sheet (SDS) must be obtained and read before handling, storage, or disposal. Available from Hydratech (sales@hydratech.co.uk) or on request. 24\/7 technical support: \u003cstrong\u003e01792 586800\u003c\/strong\u003e. Store in sealed containers below 40°C, out of direct sunlight.\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Features \u0026amp; Benefits\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(255px,1fr));gap:12px;background:#e6f4f3;padding:14px;border-radius:0 0 6px 6px;margin-bottom:22px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Ethylene Glycol Performance — Without the Toxicity\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003ePropylene glycol (MPG) became the standard non-toxic heat transfer fluid, but it has inferior heat transfer characteristics — it is more viscous, harder to pump at low temperatures, and requires larger volumes for the same freeze protection. Thermox DTX's patented \u003cstrong\u003eDeTox™ additive prevents ethylene glycol from metabolising into toxic by-products\u003c\/strong\u003e (which cause kidney failure, blindness, and death), giving it non-toxic classification while retaining EG's better thermal conductivity, lower viscosity, and more efficient freeze protection per litre.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Better Pump Performance at Low Temperatures\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eIn ground source heat pump systems where ground loop fluid temperatures can drop to –5°C to –10°C during peak demand, fluid viscosity directly affects pump energy consumption and flow rate. Thermox DTX's \u003cstrong\u003elower dynamic viscosity\u003c\/strong\u003e compared to propylene glycol reduces pumping power requirements and helps maintain the minimum flow rate through the heat pump heat exchanger — particularly important at the start of the heating season when ground temperatures are lowest.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ ASTM D1384 \u0026amp; BS6580 Corrosion Inhibited\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThermox DTX contains \u003cstrong\u003esynergistic corrosion inhibitors\u003c\/strong\u003e protecting all metals commonly found in heat pump circuits — copper, steel, cast iron, aluminium, brass, and solder. Independently tested and certified to meet \u003cstrong\u003eASTM D1384\u003c\/strong\u003e (the industry standard for heat transfer fluid corrosion performance) and \u003cstrong\u003eBS6580\u003c\/strong\u003e. Scale and biological inhibitors also included to prevent fouling and maintain thermal efficiency over the system's operating life.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Readily Biodegradable\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThermox DTX mixtures are \u003cstrong\u003ereadily biodegradable — 90% over ten days\u003c\/strong\u003e — and will not persist in the environment or bioaccumulate. This is significant for ground source and borehole installations, where a leak of fluid into the surrounding ground could raise environmental and regulatory concerns with a conventional ethylene glycol product. The DeTox™ formulation addresses this risk.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Frost Protection to –50°C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eAt standard heat pump concentrations of 22–33% (protecting to –10°C to –20°C), Thermox DTX requires \u003cstrong\u003eless concentrate volume than propylene glycol\u003c\/strong\u003e for equivalent protection. For extreme cold applications — Nordic-climate GSHP or exposed pipework — concentrations of up to 54.3% protect to –50°C. The dilution table and refractometer indices allow precise concentration checking on site.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Green-Tinted — Easy System Identification\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eMidsummer's Thermox DTX supply is \u003cstrong\u003etinted green\u003c\/strong\u003e, making it easy to confirm the presence of inhibited antifreeze fluid in a system during commissioning or servicing — a drain-down test or visual check of a small sample confirms whether the system is filled with treated fluid. This is particularly useful when taking over a system from another installer or when checking a system after top-up.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── DILUTION TABLE ─────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Dilution Guide — Frost Protection vs Concentration\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#005c54;color:#fff;\"\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;font-weight:600;\"\u003eFrost Protection (°C)\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;font-weight:600;\"\u003eThermox DTX (% v\/v)\u003c\/th\u003e\n        \u003cth style=\"padding:9px 14px;text-align:left;font-weight:600;\"\u003eRefractive Index\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–10°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e22.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.35590\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–15°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e28.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.36240\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–20°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e33.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.36780\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–25°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e38.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.37310\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–30°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e42.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.37740\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–35°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e46.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.38150\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–40°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.38570\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–45°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e52.0%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.38770\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e–50°C\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e54.3%\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e1.38970\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:8px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;width:44%;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eHydratech (alliance with Evans Cooling Systems, Inc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProduct\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eThermox DTX Non-Toxic Glycol Antifreeze Concentrate\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBase Fluid\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eEthylene glycol with DeTox™ non-toxic additive\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eContainer Size\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e25 litres\u003c\/strong\u003e (concentrate — also available 5L, 10L, 205L, 1000L IBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrost Protection Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–10°C (at 22%) to –50°C (at 54.3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMinimum Dose\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e22% v\/v (do not use below this concentration)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMaximum Dose\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e60% (normally) — contact Hydratech for higher concentrations\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDensity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1.10 – 1.15 g\/cm³ (depending on inhibitors)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003epH\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e7.5 – 9.0 (depending on inhibitors)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBoiling Point\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u0026gt;100°C (contact Hydratech for use above 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eColour (Midsummer supply)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eGreen tinted\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCorrosion Standards\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eASTM D1384; BS6580\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eQuality Standard\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eManufactured under ISO 9001:2015\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBiodegradability\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eReadily biodegradable — 90% over ten days\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eShelf Life\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eAt least 3 years — sealed container, below 40°C, out of direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003eGSHP ground loops; ASHP primary circuits; water source heat pump circuits; solar thermal; underfloor heating where non-toxic classification preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e","brand":"AIZO Quality Heating","offers":[{"title":"Default Title","offer_id":64135899677021,"sku":"thermox-dtx","price":197.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/ThermoxDTXNon-ToxicEthyleneGlycolAntifreezeHeatTransferFluid25Litre_GSHPASHPGroundAirWaterHeatPumpSystems.webp?v=1775754385","url":"https:\/\/qualityheating.co.uk\/products\/thermox-dtx-non-toxic-ethylene-glycol-antifreeze-heat-transfer-fluid-25-litre-gshp-ashp-ground-air-water-heat-pump-systems","provider":"AIZO Quality Heating","version":"1.0","type":"link"}