{"product_id":"telford-tempest-150l-indirect-heat-pump-cylinder","title":"Telford Tempest 150L Indirect Heat Pump Cylinder","description":"\u003cp style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333; margin: 0 0 1rem 0;\"\u003eThe Telford Tempest 150L Indirect Heat Pump Cylinder is a high performance unvented hot water cylinder designed for use with air source and ground source heat pump systems. Its purpose designed heat pump coil supports efficient renewable energy transfer, while the factory fitted 3kW immersion heater provides dependable backup heating when required.\u003c\/p\u003e\n\u003cp style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333; margin: 0 0 1rem 0;\"\u003eManufactured from corrosion resistant Duplex stainless steel and fully insulated to help reduce standing heat loss, this cylinder supplies mains pressure hot water with strong flow performance. It is suitable for domestic installations and selected renewable heating systems where a 150 litre hot water capacity is appropriate.\u003c\/p\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 1.5rem 0 0.8rem 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2,1fr); gap: 1rem; font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.5; margin: 0 0 1.5rem 0;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003e150 litre capacity for reliable domestic hot water storage.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eDesigned for compatible air source and ground source heat pumps.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003ePurpose designed 2m² coil for effective renewable heat transfer.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eDurable Duplex stainless steel cylinder construction.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eFactory fitted 3kW immersion heater for backup heating.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eMains pressure hot water delivery with high flow potential.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eFully insulated to help minimise standing heat loss.\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #ffffff; border-radius: 0.5rem; padding: 1rem; box-sizing: border-box;\"\u003eFull unvented safety and control components supplied.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 1.5rem 0 0.8rem 0;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.5; color: #333333; margin: 0 0 1.5rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 42%; border: 1px solid #008377CF; background: #008377CF; color: #ffffff; padding: 0.8rem; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 58%; border: 1px solid #008377CF; background: #008377CF; color: #ffffff; padding: 0.8rem; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eIndirect unvented heat pump cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eTelford\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eProduct code\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eTSMI150\/HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eNominal capacity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e150 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e1060mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eDiameter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e510mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eEmpty weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eApproximate full weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e179kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eHeat pump coil surface area\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e2m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eImmersion heater\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e3kW factory fitted immersion heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eStanding heat loss\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e1.85kWh per 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eMaximum supply pressure\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e12 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eMaximum primary pressure\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eT\u0026amp;P valve setting\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e7 bar \/ 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eCylinder material\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eDuplex stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eConnections and coil\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003e316L grade stainless steel 22mm compression fittings and coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #008377CF; padding: 0.8rem;\"\u003eLifetime manufacturing warranty on the inner container, 2 year warranty on components, subject to the manufacturer’s terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 1.5rem 0 0.8rem 0;\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333; margin: 0 0 1.5rem 1.5rem; padding: 0;\"\u003e\n\u003cli\u003e3kW immersion heater.\u003c\/li\u003e\n\u003cli\u003eTemperature and pressure relief valve.\u003c\/li\u003e\n\u003cli\u003eAcetal tundish.\u003c\/li\u003e\n\u003cli\u003eInlet control group.\u003c\/li\u003e\n\u003cli\u003e2 port valve.\u003c\/li\u003e\n\u003cli\u003eExternal expansion vessel with factory fitted wall mounting bracket.\u003c\/li\u003e\n\u003cli\u003eDual probe thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background: #e6f4f2; border-left: 0.4rem solid #008377CF; padding: 1rem; margin: 0 0 1rem 0; font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333;\"\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 0 0 0.5rem 0;\"\u003eIdeal for Heat Pump Installations\u003c\/h2\u003e\n\u003cp style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; margin: 0;\"\u003eA practical choice for homeowners and heating professionals installing compatible air source or ground source heat pump systems in homes, renovations and renewable energy upgrades.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f2faf9; border-left: 0.4rem solid #008377CF; padding: 1rem; margin: 0 0 1rem 0; font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333;\"\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 0 0 0.5rem 0;\"\u003eReliable Hot Water for Everyday Use\u003c\/h2\u003e\n\u003cp style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; margin: 0;\"\u003eThe 150 litre store is suitable for domestic hot water applications where mains pressure performance, insulation and dependable backup heating are important.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f2; border-left: 0.4rem solid #008377CF; padding: 1rem; margin: 0 0 1rem 0; font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; color: #333333;\"\u003e\n\u003ch2 style=\"font-family: Arial, sans-serif; font-size: 1.8rem; color: #008377cf; margin: 0 0 0.5rem 0;\"\u003eImportant Installation Note\u003c\/h2\u003e\n\u003cp style=\"font-family: Arial, sans-serif; font-size: 1.7rem; line-height: 1.6; margin: 0;\"\u003eA 3 port valve is not included with this model and must be purchased separately where required by the heating system design. Installation and commissioning should be completed by a suitably qualified professional.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Telford","offers":[{"title":"Default Title","offer_id":67581166518662,"sku":"TSMI150\/HP","price":1400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/telford-heat-pump-cylinder.jpg?v=1791361869","url":"https:\/\/qualityheating.co.uk\/products\/telford-tempest-150l-indirect-heat-pump-cylinder","provider":"AIZO Quality Heating","version":"1.0","type":"link"}