{"product_id":"stuart-turner-aquaboost-iboost-v200-100-45-variable-speed-mains-water-booster-46711-4-5-bar-100-l-min-200l-wras","title":"Stuart Turner Aquaboost iBoost V200-100-45 Variable Speed Mains Water Booster – 46711, 4.5 Bar, 100 l\/min, 200L, WRAS","description":"\u003c!-- SEO Product Name: Stuart Turner Aquaboost iBoost V200-100-45 Variable Speed Mains Water Booster – MPN 46711, 4.5 Bar, 100 l\/min, 200L, WRAS --\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e \u003cmeta name=\"viewport\" content=\"width=device-width,initial-scale=1\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-family: 'Segoe UI',Helvetica,Arial,sans-serif; color: #222; background: #fff; max-width: 900px; line-height: 1.5;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.75; color: #333; margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eStuart Turner Aquaboost iBoost V200-100-45\u003c\/strong\u003e (MPN \u003cstrong\u003e46711\u003c\/strong\u003e) is a \u003cstrong\u003efully integrated variable speed mains water pressure and flow boosting system\u003c\/strong\u003e combining a \u003cstrong\u003e200-litre cold water storage tank\u003c\/strong\u003e and a \u003cstrong\u003ehigh-performance multistage centrifugal pump\u003c\/strong\u003e in a single compact unit. Designed for larger domestic and light commercial properties where mains pressure and flow are insufficient to serve multiple bathrooms, showers and appliances simultaneously, the iBoost V200 delivers \u003cstrong\u003eup to 4.5 bar pressure and 100 l\/min flow\u003c\/strong\u003e — typically operating at \u003cstrong\u003e60 l\/min at 3.0 bar\u003c\/strong\u003e. The \u003cstrong\u003evariable speed pump control system\u003c\/strong\u003e (the V in V200) continuously adjusts pump speed via a pressure transducer to maintain a \u003cstrong\u003econstant, programmable outlet pressure\u003c\/strong\u003e as demand fluctuates — eliminating the pressure drops and surges that occur with fixed-speed alternatives. At \u003cstrong\u003e536mm wide × 529mm deep × 1,504mm tall\u003c\/strong\u003e, it fits within a standard 600mm kitchen larder cupboard. \u003cstrong\u003eWRAS approved (2301305)\u003c\/strong\u003e, Made in Britain, with a \u003cstrong\u003e3-year warranty\u003c\/strong\u003e and UKCA\/CE certification.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(130px,1fr)); gap: 10px; margin-bottom: 24px;\"\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e4.5 bar\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eMax Pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e100 l\/min\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eMax Flow Rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e200 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eWater Storage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e57 dB(A)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eTypical Noise\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003e3 yr\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eWarranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #005c54; color: #fff; border-radius: 8px; padding: 14px 16px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 22px; font-weight: 800; line-height: 1;\"\u003eWRAS\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; opacity: 0.85; margin-top: 4px;\"\u003eApproved — CAT 3\/4\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #005c54;\"\u003e\n\u003cstrong\u003eℹ CAT 3 \u0026amp; 4 (Domestic):\u003c\/strong\u003e The V200-100-45 (46711) is approved for Fluid Categories 3 and 4 — correct for the majority of domestic cold mains boosting applications. Where Fluid Category 5 is required (certain commercial premises), specify the \u003cstrong\u003eV200-100-45 CAT5 (46713)\u003c\/strong\u003e instead. If unsure, consult your plumber, building inspector or water supplier.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eiBoost Range — Selecting the Right Model\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 8px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #008377; color: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003ePump Control\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eMax Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eMax Flow\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eFluid Cat.\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; font-weight: bold; font-size: 13px;\"\u003eBest For\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eF200-100-45\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e46668\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eFixed speed\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e200 L\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4.5 bar\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eCAT 3\/4\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eDomestic — budget fixed-speed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eV200-100-45\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e46711\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eVariable speed\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e200 L\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4.5 bar\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eCAT 3\/4\u003c\/td\u003e\n\u003ctd style=\"background: #e6f4f3; font-weight: bold; padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eDomestic — programmable constant pressure ✓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eV200-100-45 CAT5\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e46713\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eVariable speed\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e200 L\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4.5 bar\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eCAT 5\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eCommercial \/ where CAT5 required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eV200+200\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eVariable speed\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e400 L\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e4.5 bar\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003e100 l\/min\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eCAT 3\/4\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 10px; font-size: 13px; border-bottom: 1px solid #dce8e7;\"\u003eHigh-occupancy — add iBOOST +200 (46712)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #666; margin: 4px 0 20px;\"\u003eAll models: 230V\/1Ph\/50Hz, 536×529×1504mm footprint, 3-year warranty, WRAS Approved, Made in Britain. This listing covers the \u003cstrong\u003eV200-100-45 (46711)\u003c\/strong\u003e row (✓).\u003c\/p\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eKey Features \u0026amp; Technology\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eVariable Speed Pump — Constant Programmable Pressure\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe defining difference between the V200 and the fixed-speed F200 is its \u003cstrong\u003evariable speed pump control system with pressure transducer\u003c\/strong\u003e. Rather than running at full speed whenever switched on, the V200 continuously monitors system pressure and adjusts pump speed to maintain a \u003cstrong\u003econstant, programmable outlet pressure\u003c\/strong\u003e regardless of how many outlets are open simultaneously. The pressure setpoint is \u003cstrong\u003epre-set to 3.0 bar\u003c\/strong\u003e at the factory, adjustable in \u003cstrong\u003e0.1 bar increments\u003c\/strong\u003e via the programmable control panel — so pressure stays stable whether one tap or five outlets are open at once.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eVariable speed\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePressure transducer\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003ePre-set 3.0 bar\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e±0.1 bar adj.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eSoft Start and Demand-Matched Speed — Quieter, Longer-Lived\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eVariable speed also means \u003cstrong\u003esoft start\u003c\/strong\u003e — the pump accelerates smoothly from rest rather than switching to full speed instantly, eliminating the mechanical shock and pipe water hammer that accelerates wear in fixed-speed systems. When demand is low (a single low-flow tap), the pump runs at reduced speed — \u003cstrong\u003equieter operation, lower power draw and reduced heat build-up\u003c\/strong\u003e. Typical noise is just \u003cstrong\u003e57 dB(A)\u003c\/strong\u003e. The result is a longer pump lifespan and lower running costs versus fixed-speed alternatives.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSoft start\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e57 dB(A) typical\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDemand-matched speed\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e200-Litre Buffer Storage — Mains Independence During Peak Demand\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe V200 integrates a \u003cstrong\u003e200-litre usable cold water storage tank\u003c\/strong\u003e (nominal 220 litres) manufactured from food-grade polyethylene. This buffer decouples the pump from the mains supply — the tank fills continuously via a \u003cstrong\u003ehigh-flow equilibrium float valve at up to 20 l\/min\u003c\/strong\u003e (at 1 bar inlet pressure), while the pump draws from stored volume and delivers up to \u003cstrong\u003e100 l\/min to the property\u003c\/strong\u003e. Peak demand — multiple showers, appliances and taps simultaneously — is met from stored supply regardless of the mains feed rate. An integrated \u003cstrong\u003e8-litre pressure vessel\u003c\/strong\u003e (10 bar rated) smooths minor demand fluctuations and protects the pump from cycling on micro-draws.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e200 L usable\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e20 l\/min fill rate\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e8 L pressure vessel\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e4.5 Bar \/ 100 l\/min — Sized for High-Occupancy Properties\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe V200-100-45 is rated to \u003cstrong\u003e4.5 bar maximum head\u003c\/strong\u003e (45 metres equivalent) and a \u003cstrong\u003emaximum flow rate of 100 litres per minute\u003c\/strong\u003e. Typical operating point is \u003cstrong\u003e60 l\/min at 3.0 bar\u003c\/strong\u003e — ample for a large family home or small residential building with multiple bathrooms, wet rooms and water-using appliances running concurrently. Maximum static inlet pressure is \u003cstrong\u003e7 bar\u003c\/strong\u003e; maximum static outlet is \u003cstrong\u003e15 metres head\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e4.5 bar max\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e100 l\/min max\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e60 l\/min @ 3.0 bar typical\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eFits a Standard 600mm Larder Cupboard — White Goods Appearance\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eDespite its 200-litre capacity, the iBoost V200 has been engineered to fit within a \u003cstrong\u003estandard 600mm kitchen larder cupboard\u003c\/strong\u003e: \u003cstrong\u003e536mm wide × 529mm deep × 1,504mm tall\u003c\/strong\u003e. The front panel is acrylic-capped ABS in a white goods finish — it will not look out of place alongside a fridge-freezer or washing machine in a utility room or kitchen. Filled weight is \u003cstrong\u003e256 kg\u003c\/strong\u003e — floor loading must be confirmed before installation. A \u003cstrong\u003e3-metre pre-wired power cable\u003c\/strong\u003e simplifies electrical connection.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e536×529×1504mm\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eFits 600mm cupboard\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e3m pre-wired cable\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eWRAS Approved — CAT 3 \u0026amp; CAT 4 Fluid Categories\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe iBoost V200 carries \u003cstrong\u003eWRAS approval (2301305)\u003c\/strong\u003e — the Water Regulations Advisory Scheme certification required for any product connected to the UK mains water supply. Approved for \u003cstrong\u003eFluid Categories 3 and 4\u003c\/strong\u003e, covering the vast majority of domestic and light commercial installations. The tank uses a \u003cstrong\u003eType AF air gap\u003c\/strong\u003e. \u003cem\u003eWhere Cat 5 is required, specify the V200-100-45 CAT5 (46713) instead.\u003c\/em\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eWRAS 2301305\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eCAT 3 \u0026amp; 4\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eType AF air gap\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eControl Panel, Status Indicators and Dry-Run Protection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe front-mounted \u003cstrong\u003eprogrammable control panel\u003c\/strong\u003e provides pressure setpoint adjustment, system status and fault indicators. \u003cstrong\u003eDry-run protection\u003c\/strong\u003e monitors water availability and shuts the pump down automatically if the tank empties — preventing pump damage during sustained high-demand periods or supply interruptions. A system \u003cstrong\u003echeck valve\u003c\/strong\u003e prevents backflow, and a \u003cstrong\u003eflexible outlet hose\u003c\/strong\u003e (G¾ female × 22mm push-in, 220mm long) is included for easy commissioning.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eProgrammable controls\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eDry-run protection\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eSystem check valve\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #f8f8f8; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003e3-Year Warranty — Made in Britain\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eThe iBoost V200 carries a \u003cstrong\u003e3-year manufacturer's warranty\u003c\/strong\u003e and is \u003cstrong\u003eMade in Britain\u003c\/strong\u003e by Stuart Turner, who have manufactured pumps in Henley-on-Thames, Oxfordshire since 1906. Pump body is brass and stainless steel with stainless steel impellers; the motor is a continuous-duty (S1) induction motor with current overload sensor. Certified to \u003cstrong\u003eUKCA and CE\u003c\/strong\u003e. Register the product with Stuart Turner at installation to activate the warranty.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e3-Year Warranty\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eMade in Britain\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eUKCA \/ CE\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 14px; align-items: flex-start; padding: 14px 16px; background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 6px 6px 0; margin-bottom: 8px;\"\u003e\n\u003cdiv style=\"flex-shrink: 0; width: 30px; height: 30px; background: #008377; border-radius: 50%; display: flex; align-items: center; justify-content: center;\"\u003e\u003csvg stroke-width=\"3\" stroke=\"#fff\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"15\" width=\"15\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eExpandable to 400 Litres with iBOOST +200 (46712)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #444; line-height: 1.6;\"\u003eFor very high-occupancy properties — large houses, HMOs, small hotels or residential blocks — the V200 can be paired with the \u003cstrong\u003eiBOOST +200 expansion tank (46712)\u003c\/strong\u003e to create a \u003cstrong\u003eV200+200 system with 400 litres total storage\u003c\/strong\u003e. The +200 tank includes a high-flow fill valve for rapid refill. The V200 booster unit (46711) and +200 tank (46712) are ordered separately.\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 8px;\"\u003e\n\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003eExpandable to 400 L\u003c\/span\u003e\u003cspan style=\"display: inline-block; background: #008377; color: #fff; border-radius: 20px; padding: 3px 11px; font-size: 13px; font-weight: bold; letter-spacing: 0.02em; margin: 2px 4px 2px 0; white-space: nowrap;\"\u003e+200 tank = 46712\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eTechnical Specification — iBoost V200-100-45 (Stuart Turner Official Data)\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 24px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: 'Segoe UI',Helvetica,Arial,sans-serif;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eProduct Code\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e46711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eGTIN\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e5050400467113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWRAS Approval\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e2301305 — WRAS Approved Product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eConformity Certification\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eUKCA \/ CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFluid Category\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eCAT 3, CAT 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMaximum Pressure (closed valve)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e4.5 bar (45 m head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e100 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTypical Operating Point\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e60 l\/min at 3.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax Inlet Pressure (static)\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e7 bar (700 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMax Outlet Pressure (static)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e15 m head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e4°C min — 30°C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003ePump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePump Type\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eMultistage centrifugal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePump Control System\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eVariable speed with pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePressure Setpoint\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePre-set 3.0 bar; adjustable in 0.1 bar increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eControl Interface\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eProgrammable controls (front panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePump Body\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eBrass \/ stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePump Impeller\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDuty Rating\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eContinuous S1 at 5 l\/min and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eMotor Type\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eInduction motor with current overload sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTypical Noise\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e57 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e230V a.c. \/ 1Ph \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower Consumption (P1)\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e996 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFull Load Current\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e6.8 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFuse Rating\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e10 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePower Cable\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e3 metres (pre-wired)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003eWater Tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eNominal Tank Volume\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e220 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eUsable Water Capacity\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e200 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTank Material\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003ePolyethylene (food grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFloat Valve Type\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eEquilibrium (high flow, low noise)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eTank Fill Rate\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e20 l\/min (at 1 bar inlet pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eAir Gap Type\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eType AF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePressure Vessel\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e8 litres at 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eInlet Connection\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eG½ male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003ePump Outlet Connection\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eG¾ male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOutlet Flexible Hose\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eG¾ female × 22mm push-in, 220mm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eOverflow\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eG1¼ compression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #008377; color: #fff; font-weight: bold; padding: 9px 14px; font-size: 13px; letter-spacing: 0.06em; text-transform: uppercase;\" colspan=\"2\"\u003ePhysical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e536 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e529 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e1,504 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eFront Panel Material\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003eAcrylic-capped ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWeight — empty (incl. fittings)\u003c\/td\u003e\n\u003ctd style=\"background: #f0f9f8; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; font-weight: 600; color: #333; font-size: 14px; width: 46%; border-bottom: 1px solid #e0e0e0;\"\u003eWeight — filled\u003c\/td\u003e\n\u003ctd style=\"background: #fff; padding: 9px 14px; color: #222; font-size: 14px; border-bottom: 1px solid #e0e0e0;\"\u003e256 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8e1; border-left: 4px solid #f0a500; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #5a4000;\"\u003e\n\u003cstrong\u003e⚠ Floor Loading:\u003c\/strong\u003e Filled weight is \u003cstrong\u003e256 kg\u003c\/strong\u003e. Standard domestic timber floors are unlikely to be adequate without structural reinforcement. A concrete floor or reinforced base is typically required. Always have floor loading capacity confirmed by a structural engineer or qualified installer before specifying the installation location.\u003c\/div\u003e\n\u003cdiv style=\"background: #e6f4f3; border-left: 4px solid #008377; border-radius: 0 8px 8px 0; padding: 14px 18px; margin: 6px 0 16px; font-size: 15px; color: #005c54;\"\u003e\n\u003cstrong\u003eℹ Installation:\u003c\/strong\u003e Must be installed by a \u003cstrong\u003equalified plumber\u003c\/strong\u003e in accordance with the Water Supply (Water Fittings) Regulations 1999, the iBoost Installation Guide and BS EN 806. Electrical connection must be made by a qualified electrician to a 10A fused spur. Register the product with Stuart Turner at installation to activate the warranty.\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the difference between the V200 and the F200?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eBoth models share the same 200-litre tank, 4.5 bar maximum pressure, 100 l\/min flow rate, dimensions and WRAS approval. The difference is the pump control system. The \u003cstrong\u003eF200 is fixed speed\u003c\/strong\u003e — the pump runs at full speed whenever there is demand. The \u003cstrong\u003eV200 is variable speed\u003c\/strong\u003e — the pump modulates continuously to maintain a constant programmable outlet pressure as demand rises and falls. The V200 is quieter under low demand, uses less energy at part load, starts more gently and maintains more stable pressure when multiple outlets run simultaneously.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the V200 pre-set to and can I change it?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe V200 leaves the factory pre-set to \u003cstrong\u003e3.0 bar outlet pressure\u003c\/strong\u003e. This can be adjusted via the programmable control panel in \u003cstrong\u003e0.1 bar increments\u003c\/strong\u003e up to the 4.5 bar maximum. Adjustment is typically done at commissioning by the installing engineer to suit the property's pipework, appliances and user requirements.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat is the difference between the V200 (46711) and the V200 CAT5 (46713)?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eThe \u003cstrong\u003eV200-100-45 (46711)\u003c\/strong\u003e is approved for Fluid Categories 3 and 4 — suitable for the majority of domestic and light commercial cold mains boosting applications. The \u003cstrong\u003eV200-100-45 CAT5 (46713)\u003c\/strong\u003e adds a weir overflow to the tank, making it approved for Fluid Category 5 — required in certain commercial premises and wherever the water regulations demand the highest level of backflow protection. For residential installations, CAT5 is not normally required; consult a plumbing engineer or building inspector if unsure.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eDoes the iBoost V200 work if mains pressure is very low or intermittent?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eYes — this is precisely what the iBoost is designed for. The 200-litre storage tank fills continuously from the mains via the equilibrium float valve (up to 20 l\/min at 1 bar inlet pressure). Even if mains pressure is low or temporarily interrupted, the stored volume provides the pump with sufficient supply to meet household demand. Dry-run protection shuts the pump down if the tank empties. Maximum static inlet pressure is 7 bar.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 14px 18px; font-size: 15px; font-weight: bold; color: #005c54; cursor: pointer; list-style: none; display: flex; align-items: center; justify-content: space-between; background: #f5fbfa;\"\u003e\u003cspan\u003eWhat floor loading does the V200 require?\u003c\/span\u003e\u003csvg stroke-width=\"2.5\" stroke=\"#008377\" fill=\"none\" viewbox=\"0 0 24 24\" height=\"18\" width=\"18\"\u003e\u003cpolyline points=\"6 9 12 15 18 9\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px 16px; font-size: 15px; color: #444; line-height: 1.65; border-top: 1px solid #cde3e1; background: #fff;\"\u003eFilled weight is \u003cstrong\u003e256 kg\u003c\/strong\u003e — this must be accounted for in floor loading calculations. A standard domestic timber floor is unlikely to be adequate without structural reinforcement; a concrete floor or reinforced base is typically required. Always confirm floor loading capacity with a structural engineer or qualified installer before specifying the installation location.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size: 16px; font-weight: bold; color: #005c54; border-bottom: 3px solid #008377; padding-bottom: 8px; margin: 28px 0 14px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eRelated Products\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(230px,1fr)); gap: 10px; margin-bottom: 10px;\"\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eiBOOST +200 Expansion Tank (46712)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eAdds 200 L — total 400 L V200+200 system\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eiBOOST F200-100-45 (46668)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eFixed-speed 200 L booster — lower cost option\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #cde3e1; border-radius: 8px; padding: 16px 18px; text-align: center; background: #f5fbfa;\"\u003e\n\u003cdiv style=\"font-size: 15px; font-weight: bold; color: #005c54; margin-bottom: 4px;\"\u003eiBOOST V200-100-45 CAT5 (46713)\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666;\"\u003eVariable speed with weir overflow for CAT5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Stuart Turner","offers":[{"title":"Default Title","offer_id":63917108003165,"sku":"46711","price":2300.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/AquaboostiBoostV200-100-45-46711VairableSpeedPumps.webp?v=1773920809","url":"https:\/\/qualityheating.co.uk\/products\/stuart-turner-aquaboost-iboost-v200-100-45-variable-speed-mains-water-booster-46711-4-5-bar-100-l-min-200l-wras","provider":"AIZO Quality Heating","version":"1.0","type":"link"}