{"product_id":"solaredge-ambient-temperature-sensor-0-10v","title":"SolarEdge Ambient Temperature Sensor 0–10V","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eSolarEdge SE1000-SEN-TAMB-S2\u003c\/strong\u003e is an \u003cstrong\u003eoutdoor ambient temperature sensor\u003c\/strong\u003e designed to connect to the SolarEdge Control and Communication Gateway (SE1000-CCG-G-S1) for environmental monitoring of commercial PV sites. Providing a \u003cstrong\u003e0–10V analogue output\u003c\/strong\u003e across a measurement range of \u003cstrong\u003e–40°C to +90°C\u003c\/strong\u003e with \u003cstrong\u003e1% full-scale accuracy\u003c\/strong\u003e, it supplies real-time ambient temperature data used to calculate \u003cstrong\u003esite performance ratio\u003c\/strong\u003e — enabling more accurate yield analysis and O\u0026amp;M diagnostics. Manufactured by \u003cstrong\u003eIMT Solar (Ingenieurbüro Mencke \u0026amp; Tegtmeyer GmbH)\u003c\/strong\u003e, the IMT part number is \u003cstrong\u003eTa-V-4090\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:18px;font-weight:700;\"\u003e0–10 V\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eAnalogue output\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:18px;font-weight:700;\"\u003e–40 to +90°C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eMeasurement range\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:18px;font-weight:700;\"\u003e1%\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eAccuracy (full scale)\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:18px;font-weight:700;\"\u003eIP67\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003ePowder-coated aluminium\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"border-left:4px solid #f59e0b;background:#fff8e1;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#b45309;\"\u003e⚡ Compatibility\u003c\/strong\u003e — Requires the \u003cstrong\u003eSolarEdge Control and Communication Gateway (SE1000-CCG-G-S1)\u003c\/strong\u003e, sold separately. The Gateway can power up to 3 sensors simultaneously. Warranty and service for the sensor itself are provided directly by the manufacturer, \u003cstrong\u003eIMT Solar (Ingenieurbüro Mencke \u0026amp; Tegtmeyer GmbH)\u003c\/strong\u003e. Install the sensor in a shaded location protected from direct solar radiation, precipitation, and meltwater for accurate ambient readings.\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;width:45%;border-bottom:1px solid #c8e6e3;\"\u003eSolarEdge Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSE1000-SEN-TAMB-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eIMT Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eTa-V-4090\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIngenieurbüro Mencke \u0026amp; Tegtmeyer GmbH (IMT Solar)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eElectrical Output Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\u003cstrong\u003e0–10 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1% of full scale\u003c\/strong\u003e (±2.5% of measuring value)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003ePowder-coated aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e64 × 58 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eRequired Gateway\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003eSE1000-CCG-G-S1 (Control and Communication Gateway, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhy is ambient temperature monitoring useful for a solar site?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003ePanel output power is temperature-dependent — \u003cstrong\u003ehigher ambient temperatures reduce PV yield\u003c\/strong\u003e. Logging real-time ambient temperature alongside irradiance and actual generation allows the SolarEdge monitoring platform to calculate the \u003cstrong\u003esite performance ratio (PR)\u003c\/strong\u003e — a standardised metric that removes the effect of irradiance and temperature variability, making it possible to compare actual yield against expected yield and identify underperforming strings or inverters.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eWhere should the sensor be installed?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eInstall the ambient temperature sensor in a \u003cstrong\u003eshaded location near the array\u003c\/strong\u003e, protected from direct solar radiation, precipitation, and drainage from above. A north-facing position under a ventilated radiation shield is ideal. \u003cstrong\u003eDirect sunlight will cause the sensor to read significantly higher than true ambient temperature\u003c\/strong\u003e, invalidating the performance ratio calculation. The sensor cable can be extended if required.\u003c\/div\u003e\n    \u003c\/details\u003e\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eHow many sensors can the Gateway support simultaneously?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe \u003cstrong\u003eSolarEdge Control and Communication Gateway (SE1000-CCG-G-S1) can power and read up to 3 environmental sensors simultaneously\u003c\/strong\u003e. This allows a typical combination of irradiance, ambient temperature, and module temperature sensors to be connected to a single Gateway, covering the data inputs required for a full IEC-standard performance ratio assessment.\u003c\/div\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":64053291975005,"sku":"SE1000-SEN-TAMB-S2","price":230.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolarEdgeAmbientTemperatureSensor.png?v=1775024097","url":"https:\/\/qualityheating.co.uk\/products\/solaredge-ambient-temperature-sensor-0-10v","provider":"AIZO Quality Heating","version":"1.0","type":"link"}