{"product_id":"sigenmicro-ac-branch-unlock-tool-inverter-disconnect-tool","title":"SigenMicro AC Branch Unlock Tool - Inverter Disconnect Tool","description":"\u003c!-- SEO Product Name: SigenMicro AC Branch Unlock Tool - Inverter Disconnect Tool --\u003e\n\u003cdiv style=\"font-size: 16px; max-width: 900px; margin: 0 auto; color: #2b2b2b; line-height: 1.6; font-family: Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #2b2b2b; margin: 0 0 16px 0;\"\u003eThe \u003cstrong\u003eSigenMicro AC Branch Unlock Tool\u003c\/strong\u003e is a small handheld tool designed to safely \u003cstrong\u003edisconnect a SigenMicro microinverter from the AC Trunk Cable\u003c\/strong\u003e on a rooftop solar array. The trunk connectors are deliberately locking and weatherproof, so a dedicated tool is needed to release the branch connection without damaging the cable or connector body.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #2b2b2b; margin: 0 0 16px 0;\"\u003eIt is used whenever a microinverter needs to be \u003cstrong\u003eremoved, replaced, or re-positioned\u003c\/strong\u003e — for example during fault diagnosis, servicing, or a PV module swap — allowing the installer to unclip the branch lead cleanly from the AC Trunk Cable and reconnect it, or a replacement unit, without disturbing the rest of the trunk run.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #2b2b2b; margin: 0 0 16px 0;\"\u003eThe tool is \u003cstrong\u003efork-shaped\u003c\/strong\u003e, sized specifically to the SigenMicro branch connector, and is part of the same accessory family as the AC Trunk Unlock Tool, which performs the equivalent job on the trunk couplers rather than the individual microinverter branch connections.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; width: 100%; margin: 0 0 24px 0; border-radius: 8px; overflow: hidden;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; text-align: center; padding: 14px 8px; border-right: 1px solid rgba(255,255,255,0.25);\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eBranch Level\u003c\/div\u003e\n\u003cdiv style=\"font-size: 11px; text-transform: uppercase; letter-spacing: .04em; margin-top: 4px;\"\u003eDisconnects At\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; text-align: center; padding: 14px 8px; border-right: 1px solid rgba(255,255,255,0.25);\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eFork Design\u003c\/div\u003e\n\u003cdiv style=\"font-size: 11px; text-transform: uppercase; letter-spacing: .04em; margin-top: 4px;\"\u003eTool Type\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; text-align: center; padding: 14px 8px; border-right: 1px solid rgba(255,255,255,0.25);\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eTool-Free Reconnect\u003c\/div\u003e\n\u003cdiv style=\"font-size: 11px; text-transform: uppercase; letter-spacing: .04em; margin-top: 4px;\"\u003eAfter Release\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; text-align: center; padding: 14px 8px; border-right: 1px solid rgba(255,255,255,0.25);\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eSigenMicro\u003c\/div\u003e\n\u003cdiv style=\"font-size: 11px; text-transform: uppercase; letter-spacing: .04em; margin-top: 4px;\"\u003eSystem Compatibility\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; text-align: center; padding: 14px 8px; border-right: 1px solid rgba(255,255,255,0.25);\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eHandheld\u003c\/div\u003e\n\u003cdiv style=\"font-size: 11px; text-transform: uppercase; letter-spacing: .04em; margin-top: 4px;\"\u003eForm Factor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFF6E5; border-left: 4px solid #E0942A; padding: 14px 18px; margin: 0 0 20px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #e0942a; margin-bottom: 4px; font-size: 14px;\"\u003ePlease Note\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.6; color: #2b2b2b;\"\u003eThis tool releases the connection between a \u003cstrong\u003eSigenMicro inverter and the AC Trunk Cable\u003c\/strong\u003e specifically. It is a different tool to the \u003cstrong\u003eSigenMicro AC Trunk Unlock Tool\u003c\/strong\u003e, which is used to open the AC Trunk Coupler for wiring — the two are not interchangeable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 14px; margin: 0 0 28px 0;\"\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003ePurpose-Built Fork Design\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eShaped specifically to grip and release the \u003cstrong\u003eSigenMicro branch connector\u003c\/strong\u003e without applying force to the surrounding cable jacket or trunk cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eSafe Microinverter Removal\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eLets installers \u003cstrong\u003edisconnect a single SigenMicro unit\u003c\/strong\u003e from the AC Trunk Cable for replacement, relocation, or fault-finding, without cutting or damaging the cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eNo Damage to Locking Connectors\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eDesigned to release the connector's locking mechanism cleanly, so the branch connector can be \u003cstrong\u003ereconnected and remain fully weatherproof\u003c\/strong\u003e afterwards.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eCompact Handheld Tool\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eSmall enough to carry in a standard installer tool bag alongside the SigenMicro AC Trunk Unlock Tool for full rooftop connector servicing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003ePart of the SigenMicro Accessory Range\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eDesigned as a companion tool to the AC Trunk Cable, AC Trunk Coupler, AC Trunk Terminator and Port Cap, covering the full connector servicing kit for a SigenMicro installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 16px 18px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eNo Ongoing Consumable Cost\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; line-height: 1.6; color: #3a3a3a;\"\u003eA one-off tool purchase for the installer or maintenance team — not a per-use consumable item.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"width: 100%; margin: 0 0 28px 0; border: 1px solid #D9EDEA; border-radius: 8px; overflow: hidden;\"\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: bold; padding: 10px 16px; font-size: 13px; text-transform: uppercase; letter-spacing: .04em;\"\u003eTool\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F0F9F8; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eProduct Code\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eSigenMicro AC Branch Unlock Tool\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #FFFFFF; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eFunction\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eDisconnects SigenMicro inverter from AC Trunk Cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F0F9F8; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eTool Type\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eFork-shaped hand tool\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: bold; padding: 10px 16px; font-size: 13px; text-transform: uppercase; letter-spacing: .04em;\"\u003eCompatibility\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F0F9F8; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eUsed With\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eSigenMicro 400 \/ 500 \/ 800 \/ 1000W microinverters\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #FFFFFF; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eUsed On\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eSigenMicro AC Trunk Cable branch connectors\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; background: #F0F9F8; border-bottom: 1px solid #E5EFEE;\"\u003e\n\u003cdiv style=\"padding: 9px 16px; font-weight: 600; color: #333; font-size: 14px; width: 46%;\"\u003eRelated Accessory\u003c\/div\u003e\n\u003cdiv style=\"padding: 9px 16px; color: #222; font-size: 14px; flex: 1;\"\u003eSigenMicro AC Trunk Unlock Tool (for the AC Trunk Coupler, not the branch connection)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FDECEC; border-left: 4px solid #D32F2F; padding: 14px 18px; margin: 0 0 20px 0; border-radius: 4px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #d32f2f; margin-bottom: 4px; font-size: 14px;\"\u003eImportant Safety Information\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; line-height: 1.6; color: #2b2b2b;\"\u003eDisconnecting a live microinverter from the AC bus must only be carried out by a \u003cstrong\u003equalified electrical installer\u003c\/strong\u003e with the system safely isolated where required. Always follow the manufacturer's system wiring and safety guidance before working on rooftop connectors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 24px 0;\"\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 13px 18px; font-weight: bold; font-size: 15px; cursor: pointer; list-style: none;\"\u003eWhat does the SigenMicro AC Branch Unlock Tool actually do?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px; font-size: 15px; line-height: 1.65; color: #2b2b2b; background: #fff;\"\u003eIt releases the locking connector that joins a \u003cstrong\u003eSigenMicro microinverter\u003c\/strong\u003e to the AC Trunk Cable, allowing that inverter to be disconnected for replacement or maintenance.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 13px 18px; font-weight: bold; font-size: 15px; cursor: pointer; list-style: none;\"\u003eIs this the same as the AC Trunk Unlock Tool?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px; font-size: 15px; line-height: 1.65; color: #2b2b2b; background: #fff;\"\u003eNo. The \u003cstrong\u003eAC Branch Unlock Tool\u003c\/strong\u003e disconnects an inverter from the trunk cable, while the \u003cstrong\u003eAC Trunk Unlock Tool\u003c\/strong\u003e is used to open the AC Trunk Coupler for wiring two trunk sections together.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 13px 18px; font-weight: bold; font-size: 15px; cursor: pointer; list-style: none;\"\u003eCan the connector be reused after being unlocked with this tool?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px; font-size: 15px; line-height: 1.65; color: #2b2b2b; background: #fff;\"\u003eYes, the tool is designed to release the connector \u003cstrong\u003ewithout damaging it\u003c\/strong\u003e, so the branch connection can be reconnected and remain weatherproof.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 13px 18px; font-weight: bold; font-size: 15px; cursor: pointer; list-style: none;\"\u003eDo I need this tool for a standard SigenMicro installation?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px; font-size: 15px; line-height: 1.65; color: #2b2b2b; background: #fff;\"\u003eIt is not required for initial installation, but it is a useful tool to have on hand for any future \u003cstrong\u003emicroinverter servicing, fault diagnosis, or replacement\u003c\/strong\u003e work.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #fff; padding: 13px 18px; font-weight: bold; font-size: 15px; cursor: pointer; list-style: none;\"\u003eWhich SigenMicro models is this tool compatible with?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 18px; font-size: 15px; line-height: 1.65; color: #2b2b2b; background: #fff;\"\u003eIt works with the full SigenMicro range connected via the standard AC Trunk Cable system, including the \u003cstrong\u003e400, 500, 800 and 1000W\u003c\/strong\u003e models.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":65894508986717,"sku":"14280093","price":5.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SigenMicroACBranchUnlockTool-InverterDisconnectTool.png?v=1789144418","url":"https:\/\/qualityheating.co.uk\/products\/sigenmicro-ac-branch-unlock-tool-inverter-disconnect-tool","provider":"AIZO Quality Heating","version":"1.0","type":"link"}