{"product_id":"scame-heat-pump-ac-isolator-32a-3-pole-ip66-ip69-grey","title":"Scame Heat Pump AC Isolator | 32A 3-Pole | IP66\/IP69 Grey","description":"\u003c!-- SEO Product Name: Scame Heat Pump AC Isolator | 32A 3-Pole | IP66\/IP69 Grey --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eThis \u003cstrong style=\"color:#008377CF;\"\u003eScame 32A three-pole AC isolator\u003c\/strong\u003e is purpose-selected for \u003cstrong\u003eexternal installation adjacent to heat pumps\u003c\/strong\u003e, giving installers a compact, lockable disconnection point that meets the weatherproofing demands of outdoor heat pump siting. Rated \u003cstrong\u003eIP66\/IP69\u003c\/strong\u003e, it stands up to jet washing, driving rain and sustained outdoor exposure without compromising the switch mechanism.\u003c\/p\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 16px 0;\"\u003eBuilt to \u003cstrong\u003eEN 60947-3\u003c\/strong\u003e as a switch-disconnector, the isolator can be padlocked in either the on or off position — an essential safe-isolation feature for engineers working on heat pump outdoor units. Its low-profile, more attractive housing design distinguishes it from typical utilitarian isolators, making it a neater fit next to a heat pump than many competing general-purpose enclosures.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:20px -4px 24px -4px;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003e32A\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eRated current\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003e3-Pole\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eConfiguration\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003e690V\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eRated voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003eIP66\/IP69\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eIngress protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003eIK09\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eImpact resistance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#F7FAFA; border:1px solid #D9EDEA; border-radius:8px; padding:14px 10px; text-align:center; margin:4px;\"\u003e\n\u003cdiv style=\"font-size:19px; font-weight:800; color:#008377CF;\"\u003e650°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12.5px; color:#555; margin-top:4px; line-height:1.3;\"\u003eGlow wire rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; border-radius:6px; padding:14px 18px; margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#008377CF; font-size:13px; text-transform:uppercase; letter-spacing:0.04em; margin-bottom:6px;\"\u003eGood to Know\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px; color:#333; line-height:1.6;\"\u003eThis isolator is rated for circuits \u003cstrong\u003eup to 32A on three-phase supplies\u003c\/strong\u003e and can be \u003cstrong\u003epadlocked in either the off or on position\u003c\/strong\u003e for safe isolation during maintenance and commissioning work.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; color:#00625D; margin:32px 0 14px 0; padding-bottom:8px; border-bottom:2px solid #008377CF;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; margin:10px -6px 24px -6px;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eLockable Off\/On Positions\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eCan be \u003cstrong\u003epadlocked in the off or on position\u003c\/strong\u003e, supporting safe isolation procedures during heat pump servicing and commissioning.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eHigh Ingress Protection\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eRated \u003cstrong\u003eIP66\/IP69\u003c\/strong\u003e, suitable for exposed external locations subject to heavy rain, dust and pressure washing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eImpact Resistant Housing\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eIK09 impact rating and a glow wire rating of 650°C give robust protection against mechanical knocks and fire risk.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003ePurpose-Selected for Heat Pumps\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eSpecially selected for \u003cstrong\u003eexternal installation adjacent to heat pumps\u003c\/strong\u003e, with a more attractive housing design than typical competitor isolators.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eEngineering Plastic Construction\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eDurable engineering plastic housing in grey\/black, built to withstand sustained outdoor exposure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; background:#fff; border:1px solid #D9EDEA; border-radius:8px; padding:16px 18px; margin:6px;\"\u003e\n\u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eCompliant Switch-Disconnector\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px; color:#444; line-height:1.55;\"\u003eManufactured to \u003cstrong\u003eEN 60947-3\u003c\/strong\u003e and EN 60947-1 switchgear standards under the EU Low Voltage Directive.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; color:#00625D; margin:32px 0 14px 0; padding-bottom:8px; border-bottom:2px solid #008377CF;\"\u003eTechnical Specification\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #D9EDEA; border-radius:8px; overflow:hidden; margin:10px 0 24px 0;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#fff; font-weight:700; font-size:13px; letter-spacing:0.05em; text-transform:uppercase; padding:10px 16px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eRated Current\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e32A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003ePoles\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e3P\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eRated Voltage\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e690V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eSwitch Size\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eY1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#fff; font-weight:700; font-size:13px; letter-spacing:0.05em; text-transform:uppercase; padding:10px 16px;\"\u003eProtection \u0026amp; Materials\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eIngress Protection\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eIP66 \/ IP69\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eImpact Protection (IK)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eIK09\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eGlow Wire Rating\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e650°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eMaterial\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eEngineering plastic\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eColour\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eGrey\/Black\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#fff; font-weight:700; font-size:13px; letter-spacing:0.05em; text-transform:uppercase; padding:10px 16px;\"\u003ePhysical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eDimensions (W x H x D)\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e110 x 150 x 87mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eFlange Size\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003e106 x 150mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eProduct Type\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eSwitch disconnector, general lockable isolator\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF; color:#fff; font-weight:700; font-size:13px; letter-spacing:0.05em; text-transform:uppercase; padding:10px 16px;\"\u003eStandards\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eSwitchgear Standard\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eEN 60947-3 (switches, disconnectors, switch-disconnectors)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#F7FAFA; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eGeneral Rules Standard\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eEN 60947-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; background:#FFFFFF; border-bottom:1px solid #D9EDEA;\"\u003e\n\u003cdiv style=\"flex:0 0 46%; padding:9px 16px; font-weight:600; font-size:14px; color:#333;\"\u003eDirective\u003c\/div\u003e\n\u003cdiv style=\"flex:1; padding:9px 16px; font-size:14px; color:#222;\"\u003eLow Voltage Directive 2014\/35\/EU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:19px; font-weight:700; color:#00625D; margin:32px 0 14px 0; padding-bottom:8px; border-bottom:2px solid #008377CF;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"margin:10px 0 24px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; font-weight:700; font-size:14.5px; cursor:pointer; list-style:none; display:flex; justify-content:space-between; align-items:center;\"\u003e\u003cspan\u003eWhat is the maximum current rating of this isolator?\u003c\/span\u003e\u003cspan style=\"font-size:13px; color:#008377CF;\"\u003e▼\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#fff;\"\u003eThis isolator is rated at \u003cstrong\u003e32A on three-phase (3-pole) circuits\u003c\/strong\u003e, suitable for the electrical supply requirements of most domestic and light commercial heat pump installations.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; font-weight:700; font-size:14.5px; cursor:pointer; list-style:none; display:flex; justify-content:space-between; align-items:center;\"\u003e\u003cspan\u003eCan this isolator be locked?\u003c\/span\u003e\u003cspan style=\"font-size:13px; color:#008377CF;\"\u003e▼\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#fff;\"\u003eYes. It \u003cstrong\u003ecan be padlocked in either the off or on position\u003c\/strong\u003e, supporting safe isolation practices during installation, commissioning and maintenance work.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; font-weight:700; font-size:14.5px; cursor:pointer; list-style:none; display:flex; justify-content:space-between; align-items:center;\"\u003e\u003cspan\u003eIs it suitable for outdoor installation?\u003c\/span\u003e\u003cspan style=\"font-size:13px; color:#008377CF;\"\u003e▼\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#fff;\"\u003eYes, it is rated \u003cstrong\u003eIP66\/IP69\u003c\/strong\u003e and specifically selected for external installation adjacent to heat pumps, giving high resistance to rain, dust and pressure washing.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; font-weight:700; font-size:14.5px; cursor:pointer; list-style:none; display:flex; justify-content:space-between; align-items:center;\"\u003e\u003cspan\u003eWhat standards does the isolator meet?\u003c\/span\u003e\u003cspan style=\"font-size:13px; color:#008377CF;\"\u003e▼\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#fff;\"\u003eIt is manufactured to \u003cstrong\u003eEN 60947-3\u003c\/strong\u003e (switches, disconnectors and switch-disconnectors) and EN 60947-1, in compliance with the EU Low Voltage Directive 2014\/35\/EU.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #D9EDEA; border-radius:8px; margin-bottom:10px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#fff; padding:12px 16px; font-weight:700; font-size:14.5px; cursor:pointer; list-style:none; display:flex; justify-content:space-between; align-items:center;\"\u003e\u003cspan\u003eWhat are the physical dimensions?\u003c\/span\u003e\u003cspan style=\"font-size:13px; color:#008377CF;\"\u003e▼\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#333; line-height:1.6; background:#fff;\"\u003eThe isolator measures \u003cstrong\u003e110 x 150 x 87mm\u003c\/strong\u003e with a flange size of 106 x 150mm.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Scame","offers":[{"title":"Default Title","offer_id":66014056743261,"sku":"590.GE3213","price":39.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Scameheatpumpisolator32a3polegrey.jpg?v=1790234309","url":"https:\/\/qualityheating.co.uk\/products\/scame-heat-pump-ac-isolator-32a-3-pole-ip66-ip69-grey","provider":"AIZO Quality Heating","version":"1.0","type":"link"}