{"product_id":"saniflo-sanicondens-pro-condensate-pump-1082-5-boiler-condensate-4-5m-lift-50m-horizontal-60w-220-240v","title":"Saniflo Sanicondens Pro Condensate Pump 1082\/5 | Boiler Condensate | 4.5m Lift | 50m Horizontal | 60W | 220-240V","description":"\u003cstyle\u003e\n  .sc-wrap{font-family:inherit;color:inherit;line-height:1.7;font-size:16px}\n  .sc-wrap p,.sc-wrap li,.sc-wrap td,.sc-wrap th{font-size:16px!important;line-height:1.7}\n  .sc-wrap h2{font-size:22px!important;font-weight:700;color:#1a3a5c;border-bottom:3px solid #0066a1;padding-bottom:6px;margin:2rem 0 1rem;line-height:1.3}\n  .sc-wrap h3{font-size:17px!important;font-weight:700;color:#1a3a5c;margin:1.2rem 0 0.4rem;line-height:1.4}\n  .sc-wrap p{margin:0 0 1rem}\n  .sc-wrap ul{padding-left:1.5rem;margin:0 0 1rem}\n  .sc-wrap ul li{margin-bottom:0.5rem}\n  .sc-badge{display:inline-block;font-size:13px!important;font-weight:700;border-radius:4px;padding:2px 10px;margin-right:5px;margin-bottom:4px;vertical-align:middle}\n  .sc-badge.blue{background:#0066a1;color:#fff}\n  .sc-badge.navy{background:#1a3a5c;color:#fff}\n  .sc-badge.green{background:#1a7a3c;color:#fff}\n  .sc-badge.grey{background:#555;color:#fff}\n  .sc-intro-box{background:#e3f2fd;border-left:4px solid #0066a1;padding:1.1rem 1.4rem;border-radius:0 6px 6px 0;margin-bottom:1.5rem}\n  .sc-intro-box p{margin:0!important}\n  .sc-stat-bar{display:grid;grid-template-columns:repeat(auto-fill,minmax(130px,1fr));gap:0.75rem;margin-bottom:1.5rem}\n  .sc-stat{text-align:center;background:#1a3a5c;color:#fff;border-radius:8px;padding:0.85rem 0.5rem}\n  .sc-stat .val{font-size:26px!important;font-weight:800;color:#90caf9;display:block;line-height:1.1}\n  .sc-stat .lbl{font-size:12px!important;opacity:0.85;display:block;margin-top:4px}\n  .sc-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(230px,1fr));gap:0.85rem;margin-bottom:1.2rem}\n  .sc-card{background:#e3f2fd;border:1px solid #90caf9;border-radius:6px;padding:1rem 1.1rem;line-height:1.6}\n  .sc-card strong{display:block;color:#1a3a5c;margin-bottom:0.35rem;font-size:16px!important}\n  .sc-warn-box{background:#fff3cd;border:1px solid #ffc107;border-radius:5px;padding:0.9rem 1.1rem;margin:1rem 0}\n  .sc-warn-box strong{display:block;margin-bottom:0.4rem}\n  .sc-spec-table{width:100%;border-collapse:collapse;margin-bottom:1.5rem}\n  .sc-spec-table th{background:#1a3a5c;color:#fff!important;text-align:left;padding:0.7rem 1rem;font-weight:700;font-size:16px!important}\n  .sc-spec-table td{padding:0.6rem 1rem;border-bottom:1px solid #bbdefb;vertical-align:top;font-size:16px!important}\n  .sc-spec-table tr:nth-child(even) td{background:#e3f2fd}\n  .sc-spec-table td:first-child{font-weight:600;color:#111;width:44%}\n  .sc-faq-item{border-bottom:1px solid #bbdefb;padding:0.9rem 0}\n  .sc-faq-item:last-child{border-bottom:none}\n  .sc-faq-item strong{color:#1a3a5c;font-size:16px!important;display:block;margin-bottom:0.3rem}\n  .sc-contents-grid{display:grid;grid-template-columns:repeat(auto-fill,minmax(200px,1fr));gap:0.6rem;margin-bottom:1.2rem}\n  .sc-contents-item{background:#e3f2fd;border:1px solid #90caf9;border-radius:5px;padding:0.6rem 0.9rem;font-size:15px!important}\n\u003c\/style\u003e\n\u003cdiv class=\"sc-wrap\"\u003e\n\n  \u003cdiv style=\"margin-bottom:1rem\"\u003e\n    \u003cspan class=\"sc-badge blue\"\u003e1082\/5\u003c\/span\u003e\n    \u003cspan class=\"sc-badge navy\"\u003eSanicondens Pro\u003c\/span\u003e\n    \u003cspan class=\"sc-badge green\"\u003e2-Year Warranty\u003c\/span\u003e\n    \u003cspan class=\"sc-badge grey\"\u003eIP20\u003c\/span\u003e\n    \u003cspan class=\"sc-badge grey\"\u003eMade in France\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-intro-box\"\u003e\n    \u003cp\u003e\u003cstrong\u003eSaniflo Sanicondens Pro Condensate Pump (1082\/5)\u003c\/strong\u003e — Compact automatic condensate lift pump for condensing boilers, air conditioners, dehumidifiers \u0026amp; refrigerated units  |  4.5m vertical \/ 50m horizontal discharge  |  2.2L tank  |  \u0026lt;45 dB(A) quiet operation  |  220–240V  |  Wall or floor mount  |  2-year warranty\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-stat-bar\"\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e4.5m\u003c\/span\u003e\u003cspan class=\"lbl\"\u003eMax vertical lift\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e50m\u003c\/span\u003e\u003cspan class=\"lbl\"\u003eMax horizontal discharge\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e2.2L\u003c\/span\u003e\u003cspan class=\"lbl\"\u003eTank capacity\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e342\u003c\/span\u003e\u003cspan class=\"lbl\"\u003eL\/hr max flow\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e\u0026lt;45\u003c\/span\u003e\u003cspan class=\"lbl\"\u003edB(A) noise level\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"sc-stat\"\u003e\n\u003cspan class=\"val\"\u003e60W\u003c\/span\u003e\u003cspan class=\"lbl\"\u003ePower consumption\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eAutomatic Condensate Removal — No Gravity Drain Required\u003c\/h2\u003e\n\n  \u003cp\u003eThe \u003cstrong\u003eSaniflo Sanicondens Pro (1082\/5)\u003c\/strong\u003e is a compact automatic condensate pump purpose-built to lift and discharge acidic condensate when gravity drainage to a soil stack or drain is not possible or practical. It is ideal for condensing boilers, air conditioning units, dehumidifiers and refrigerated display cases — any appliance that produces condensate as a by-product of its operation.\u003c\/p\u003e\n\n  \u003cp\u003eInside the unit, a \u003cstrong\u003elarge 2.2-litre reservoir\u003c\/strong\u003e collects incoming condensate. When the water level rises, an internal float automatically activates the sealed motor, which drives the pump impeller and forces the condensate out through the discharge hose — lifting it up to \u003cstrong\u003e4.5 metres vertically\u003c\/strong\u003e and pushing it up to \u003cstrong\u003e50 metres horizontally\u003c\/strong\u003e with a 1% fall. Once pumped, the float deactivates the motor until condensate accumulates again. Cycle times are typically just 3–5 seconds, keeping power consumption to a minimum.\u003c\/p\u003e\n\n  \u003cp\u003eThe large tank is specifically designed to reduce the frequency of motor start cycles, protecting the motor from excessive wear and extending its operational life. The unit also includes a built-in non-return (check) valve on the discharge to prevent backflow into the reservoir.\u003c\/p\u003e\n\n  \u003cdiv class=\"sc-warn-box\"\u003e\n    \u003cstrong\u003e⚠️ Important: Use with Condensing Boilers Requires a Neutraliser\u003c\/strong\u003e\n    \u003cp style=\"margin:0.4rem 0 0\"\u003eCondensate from gas and oil condensing boilers is mildly acidic (pH as low as 2.5) and should be neutralised before discharge to a drain in most local authority jurisdictions. When used with a condensing boiler, the Sanicondens Pro must be installed in conjunction with the \u003cstrong\u003eSaniflo Sanineutral\u003c\/strong\u003e or \u003cstrong\u003eSanineutral Mini\u003c\/strong\u003e neutralising filter (sold separately). No neutraliser is required for air conditioners, dehumidifiers or refrigerated units.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eApplications\u003c\/h2\u003e\n\n  \u003cdiv class=\"sc-grid\"\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🔥 Condensing Gas \u0026amp; Oil Boilers\u003c\/strong\u003e\n      Discharges boiler condensate when no gravity drain route exists. Use with Sanineutral neutralising filter. Supports gas boilers up to 50kW and oil boilers up to 30kW.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e❄️ Air Conditioning Units\u003c\/strong\u003e\n      Removes condensate from split-system and cassette air conditioning units installed where drainage is not readily accessible.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e💧 Dehumidifiers\u003c\/strong\u003e\n      Automatically pumps dehumidifier condensate to a remote drain, removing the need to manually empty a collection tank.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🧊 Refrigerated Display Cases\u003c\/strong\u003e\n      Used in commercial refrigeration to dispose of defrost water and condensate where drain connections are impractical.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🏠 MVHR \/ Double-Flow Ventilation\u003c\/strong\u003e\n      Can be used on mechanical ventilation with heat recovery (MVHR) systems to lift and discharge condensate from the heat exchanger unit.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🏢 Residential \u0026amp; Commercial\u003c\/strong\u003e\n      Suitable for domestic properties, light commercial premises and anywhere condensate cannot drain freely under gravity.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n\n  \u003cdiv class=\"sc-grid\"\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🔇 Quiet Operation — \u0026lt;45 dB(A)\u003c\/strong\u003e\n      Noise level below 45 dB(A) — quieter than a library. Suitable for installation in kitchens, utility rooms and boiler cupboards without causing disturbance.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e📦 Large 2.2L Tank\u003c\/strong\u003e\n      The generous reservoir reduces start-stop frequency, protecting the motor from excessive cycling and dramatically extending service life.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🔒 Built-In Non-Return Valve\u003c\/strong\u003e\n      The discharge connection includes a check valve that prevents condensate backflowing into the reservoir when the pump stops.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🔔 Alarm Pre-Connection\u003c\/strong\u003e\n      The unit is pre-wired with an alarm connection cable for optional integration with an external overflow alarm or boiler lockout circuit — providing early warning in the event of a blockage or pump failure.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🪛 Flexible Mounting\u003c\/strong\u003e\n      Mounts on a wall bracket or stands freely on a horizontal surface. Two 28mm inlets accommodate condensate from one or two appliances simultaneously.\n    \u003c\/div\u003e\n    \u003cdiv class=\"sc-card\"\u003e\n      \u003cstrong\u003e🇫🇷 Saniflo Quality\u003c\/strong\u003e\n      Designed, manufactured and tested in France. Backed by 60+ years of pump engineering expertise and a 2-year manufacturer's warranty.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\n  \u003cdiv class=\"sc-contents-grid\"\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ 1× Sanicondens Pro pump unit\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ 1× Non-return (check) valve\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ 6m flexible discharge hose (8mm)\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ 1.5m power cable\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ Inlet adapter(s)\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ Rubber plug (unused inlet blanking)\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ Alarm pre-connection cable\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ Fixing screws\u003c\/div\u003e\n    \u003cdiv class=\"sc-contents-item\"\u003e✅ Installation instructions\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n  \u003ctable class=\"sc-spec-table\"\u003e\n    \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSanicondens Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1082\/5 (Saniflo code: 1140)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSaniflo (SFA)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220–240V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e60W\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e0.52A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eElectrical Class\u003c\/td\u003e\n\u003ctd\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eTank Volume\u003c\/td\u003e\n\u003ctd\u003e2.2 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNumber of Inlets\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eInlet Diameter\u003c\/td\u003e\n\u003ctd\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDischarge Pipe Diameter\u003c\/td\u003e\n\u003ctd\u003e8mm (10mm adapter supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Vertical Lift\u003c\/td\u003e\n\u003ctd\u003e4.5m\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Horizontal Discharge\u003c\/td\u003e\n\u003ctd\u003e50m (with 1% fall)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Flow Rate\u003c\/td\u003e\n\u003ctd\u003e342 L\/hr (6.2 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNormal Working Temperature\u003c\/td\u003e\n\u003ctd\u003e35°C (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Water Temperature\u003c\/td\u003e\n\u003ctd\u003e80°C (intermittent only)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMinimum pH\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Boiler Output (gas)\u003c\/td\u003e\n\u003ctd\u003e50kW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMax Boiler Output (oil)\u003c\/td\u003e\n\u003ctd\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e231 × 120 × 143mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;45 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall bracket or floor standing\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eInstallation Overview\u003c\/h2\u003e\n\n  \u003cp\u003eThe Sanicondens Pro connects inline on the condensate outlet pipe(s) from your boiler, air conditioning unit or other appliance. Connect the appliance condensate outlet to one of the 28mm inlets on the top of the unit using the supplied adapters (rubber plug the unused inlet if only one appliance is connected). Run the 8mm or 10mm flexible discharge hose from the pump outlet up and away to the nearest suitable drain point — keeping within the 4.5m vertical and 50m horizontal limits. Connect the 1.5m mains lead to a fused spur or suitable electrical connection, and optionally connect the alarm pre-connection cable to an external overflow alarm or boiler lockout relay.\u003c\/p\u003e\n\n  \u003cp\u003eThe pump can be wall-mounted using the integrated fixing holes or placed on a flat surface beside or below the boiler. It must not be installed above the boiler or heat source. When used with a condensing boiler, fit the Sanineutral or Sanineutral Mini neutralising filter in the condensate line upstream of the pump inlet.\u003c\/p\u003e\n\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eDo I need a neutraliser with this pump?\u003c\/strong\u003e\n    If you are using it with a condensing boiler, yes — boiler condensate is acidic and most local water authorities require it to be neutralised before discharge to a drain. Connect a Saniflo Sanineutral or Sanineutral Mini upstream of the pump inlet. For air conditioners, dehumidifiers and refrigerated units, no neutraliser is typically required.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eWhat is the difference between the Sanicondens Pro and the Sanicondens Pro V02?\u003c\/strong\u003e\n    The Sanicondens Pro V02 (SK6) is the updated successor to the original Sanicondens Pro (1082\/5). The V02 has a revised design. If ordering, please check current stock availability — some suppliers may supply the V02 as the current equivalent. Check dimensions if retrofitting.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eCan it handle hot condensate from the boiler?\u003c\/strong\u003e\n    The pump is designed for continuous operation with condensate at up to 35°C, which covers normal boiler condensate temperatures. It can handle occasional spikes up to 80°C (e.g. during boiler start-up) but continuous operation at elevated temperatures is not recommended.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eCan I connect two appliances to one pump?\u003c\/strong\u003e\n    Yes — the Sanicondens Pro has two 28mm inlets. You can connect condensate from two separate appliances (e.g. a boiler and an air conditioning unit) to the same pump. Blank off the unused inlet with the supplied rubber plug if only one appliance is connected.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eWhat happens if the pump fails or becomes blocked?\u003c\/strong\u003e\n    The pre-wired alarm terminal allows connection to an external overflow alarm or boiler lockout circuit. If the pump cannot discharge condensate fast enough and the reservoir fills, the alarm circuit can trigger an audible alert or shut down the boiler to prevent condensate overflow — protecting the installation from water damage.\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"sc-faq-item\"\u003e\n    \u003cstrong\u003eHow quiet is the pump in operation?\u003c\/strong\u003e\n    The Sanicondens Pro operates at below 45 dB(A) — quieter than a normal conversation at close range. Combined with very short running cycles (typically 3–5 seconds), it is barely noticeable in a utility room or boiler cupboard. The large 2.2-litre tank also reduces the number of start cycles, further minimising noise.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Saniflo","offers":[{"title":"Default Title","offer_id":63666007540061,"sku":"1082\/5","price":70.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SanifloSanicondensProCondensatePump1082.jpg?v=1772357016","url":"https:\/\/qualityheating.co.uk\/products\/saniflo-sanicondens-pro-condensate-pump-1082-5-boiler-condensate-4-5m-lift-50m-horizontal-60w-220-240v","provider":"AIZO Quality Heating","version":"1.0","type":"link"}