{"product_id":"pressure-relief-valve-electric-water-heater-male-thread-x-female-bsp-brass-0-8mpa","title":"0.8mpa Pressure Relief Valve Electric Water Heater - Male Thread x Female BSP Brass","description":"\u003c!-- SEO Product Name: Pressure Relief Valve ELDOM Electric Water Heater - Male Thread x Female BSP Brass 0.8mpa --\u003e\n\u003cdiv style=\"font-size: 16px; max-width: 900px; margin: 0 auto; color: #2b2b2b; line-height: 1.6; font-family: Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #2b2b2b; margin: 0 0 16px 0;\"\u003eThis \u003cb\u003ebrass pressure relief valve\u003c\/b\u003e is a direct-fit safety component for electric storage water heaters, combining three essential safety functions in a single compact unit: \u003cb\u003eoverpressure relief\u003c\/b\u003e, \u003cb\u003econtrolled drain-down\u003c\/b\u003e, and \u003cb\u003enon-return (check valve) protection\u003c\/b\u003e. Set to open at \u003cb\u003e0.8 MPa (8 bar)\u003c\/b\u003e, it protects the cylinder and connected pipework from damaging pressure build-up as water is heated, while its integral check valve stops heated water flowing back into the cold mains supply.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #2b2b2b; margin: 0 0 16px 0;\"\u003eFitted with a \u003cb\u003e1\/2\" male thread x female BSP thread\u003c\/b\u003e connection, it is manufactured from \u003cb\u003esolid brass\u003c\/b\u003e for long-term corrosion resistance and reliable operation under sustained pressure and temperature cycling. It is a straightforward like-for-like replacement part for electric water heaters specified with an 0.8 MPa safety valve, and doubles as a maintenance drain point when the system needs to be emptied down.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; margin: 20px -4px;\"\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003e0.8 MPa\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eRelief Set Pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003e8 Bar\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eRelief Set Pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003e1\/2\"\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eThread Size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eMale x Female\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eBSP Connection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003eBrass\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eBody Material\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 140px; background: #008377CF; color: #ffffff; border-radius: 8px; padding: 14px 10px; text-align: center; margin: 4px;\"\u003e\n\u003cdiv style=\"font-size: 18px; font-weight: bold; line-height: 1.2;\"\u003e100°C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; opacity: 0.9; margin-top: 4px;\"\u003eMax. Working Temp\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #E6F4F3; border-left: 5px solid #008377CF; border-radius: 6px; padding: 14px 18px; margin: 18px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; font-size: 14px; margin-bottom: 4px; text-transform: uppercase; letter-spacing: 0.03em;\"\u003eGood to Know\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #2b2b2b; line-height: 1.6;\"\u003eThis valve performs \u003cb\u003ethree safety functions in one fitting\u003c\/b\u003e: it relieves excess pressure caused by thermal expansion during heating, provides a \u003cb\u003edrain point\u003c\/b\u003e for servicing or decommissioning the cylinder, and acts as a \u003cb\u003enon-return valve\u003c\/b\u003e to prevent hot water backflowing into the cold mains.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FDECEC; border-left: 5px solid #D32F2F; border-radius: 6px; padding: 14px 18px; margin: 18px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #d32f2f; font-size: 14px; margin-bottom: 4px; text-transform: uppercase; letter-spacing: 0.03em;\"\u003eImportant Safety Information\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #2b2b2b; line-height: 1.6;\"\u003e\n\u003cb\u003ePressure rating must match the water heater it is fitted to.\u003c\/b\u003e This is the \u003cb\u003e0.8 MPa (8 bar)\u003c\/b\u003e version — do not substitute a 0.7 MPa (7 bar) or other rated valve, as the relief point must correspond to the maximum working pressure stated by the water heater manufacturer. Installation and replacement of pressure\/safety valves should be carried out by a \u003cb\u003ecompetent person\u003c\/b\u003e in line with the water heater manufacturer's instructions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #FFF6E5; border-left: 5px solid #E0942A; border-radius: 6px; padding: 14px 18px; margin: 18px 0;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #e0942a; font-size: 14px; margin-bottom: 4px; text-transform: uppercase; letter-spacing: 0.03em;\"\u003ePlease Note\u003c\/div\u003e\n\u003cdiv style=\"font-size: 15px; color: #2b2b2b; line-height: 1.6;\"\u003eConfirm the \u003cb\u003ethread size and pressure rating printed on your existing valve or heater data plate\u003c\/b\u003e before ordering, as electric water heaters in this class are also supplied with 0.6 MPa and 0.7 MPa rated valves depending on model and market. This listing is for the \u003cb\u003e1\/2\" BSP, 0.8 MPa\u003c\/b\u003e variant only.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00625d; border-bottom: 2px solid #008377CF; padding-bottom: 6px; margin: 28px 0 14px 0;\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; margin: 0 -6px 10px -6px;\"\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eCombined Safety Valve\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eIntegrates an \u003cb\u003eoverpressure relief valve\u003c\/b\u003e, a \u003cb\u003edrain valve\u003c\/b\u003e, and a \u003cb\u003enon-return (check) valve\u003c\/b\u003e into one compact brass fitting, reducing the number of separate components needed on the cold feed.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003e0.8 MPa Relief Setting\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eOpens at \u003cb\u003e0.8 MPa (8 bar)\u003c\/b\u003e to release excess pressure generated by thermal expansion as the water heater cycles, protecting the cylinder and pipework from damage.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eBackflow Protection\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eThe built-in \u003cb\u003echeck valve\u003c\/b\u003e stops heated water in the cylinder from flowing back into the cold mains supply, protecting the freshwater system from contamination.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eSolid Brass Construction\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eManufactured from \u003cb\u003ebrass\u003c\/b\u003e for strong corrosion resistance and dependable long-term performance under repeated pressure and temperature cycling.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003e1\/2\" Male x Female BSP\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eFitted with a \u003cb\u003e1\/2\" male thread\u003c\/b\u003e on one side and a \u003cb\u003efemale BSP thread\u003c\/b\u003e on the other for straightforward in-line connection to standard UK water heater pipework.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #F7FAFA; border: 1px solid #D9EDEA; border-radius: 8px; padding: 14px 16px; flex: 1 1 260px; margin: 6px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #00625d; font-size: 15px; margin-bottom: 6px;\"\u003eCompact, Easy-Fit Design\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #3a3a3a; line-height: 1.55;\"\u003eA \u003cb\u003esmall, lightweight footprint\u003c\/b\u003e makes it simple to install, service, or replace without disturbing surrounding pipework.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00625d; border-bottom: 2px solid #008377CF; padding-bottom: 6px; margin: 28px 0 14px 0;\"\u003eTechnical Specification\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 10px 0 20px 0; border: 1px solid #D9EDEA; border-radius: 6px; overflow: hidden;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 13px; letter-spacing: 0.04em; text-transform: uppercase; padding: 8px 14px;\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eRelief Set Pressure\u003c\/td\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003e0.8 MPa (8 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #F7FAFA; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eMaximum Working Temperature\u003c\/td\u003e\n\u003ctd style=\"background: #F7FAFA; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003e100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003ePressure relief, drain valve, non-return (check) valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 13px; letter-spacing: 0.04em; text-transform: uppercase; padding: 8px 14px;\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eThread Size\u003c\/td\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #F7FAFA; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eThread Type\u003c\/td\u003e\n\u003ctd style=\"background: #F7FAFA; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003eMale thread x Female BSP thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 13px; letter-spacing: 0.04em; text-transform: uppercase; padding: 8px 14px;\"\u003eConstruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eBody Material\u003c\/td\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 13px; letter-spacing: 0.04em; text-transform: uppercase; padding: 8px 14px;\"\u003eCompatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; font-weight: 600; color: #333333; font-size: 14px; width: 45%; border-bottom: 1px solid #D9EDEA;\"\u003eSuitable For\u003c\/td\u003e\n\u003ctd style=\"background: #FFFFFF; padding: 9px 14px; color: #222222; font-size: 14px; border-bottom: 1px solid #D9EDEA;\"\u003eElectric storage water heaters requiring an 0.8 MPa rated safety valve, including. AIZO Technologies, ELDOM, Thermex and QH (Quality Heating) models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00625d; border-bottom: 2px solid #008377CF; padding-bottom: 6px; margin: 28px 0 14px 0;\"\u003eWhat's Included\u003c\/div\u003e\n\u003cul style=\"padding-left: 20px; font-size: 14px; color: #333333;\"\u003e\n\u003cli style=\"margin-bottom: 6px;\"\u003e1 x Pressure Relief Valve — 1\/2\" Male x Female BSP, Brass, 0.8 MPa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"font-weight: bold; font-size: 17px; color: #00625d; border-bottom: 2px solid #008377CF; padding-bottom: 6px; margin: 28px 0 14px 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eWhat does this valve do?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eIt performs \u003cb\u003ethree functions\u003c\/b\u003e in one fitting: it releases excess pressure from the water heater once it reaches \u003cb\u003e0.8 MPa (8 bar)\u003c\/b\u003e, provides a \u003cb\u003edrain point\u003c\/b\u003e for servicing the cylinder, and includes a \u003cb\u003enon-return valve\u003c\/b\u003e to stop hot water flowing back into the cold mains.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eIs this the same as a 0.7 MPa valve?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eNo. This is the \u003cb\u003e0.8 MPa (8 bar)\u003c\/b\u003e rated version. The relief pressure must match the rating specified for your water heater — fitting the wrong pressure rating can either cause nuisance discharging or fail to protect the cylinder correctly.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eWhat thread size does it use?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eA \u003cb\u003e1\/2\" male thread x female BSP thread\u003c\/b\u003e connection, sized for standard UK electric water heater pipework.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eCan I use this to drain my water heater?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eYes — the valve's \u003cb\u003edrain function\u003c\/b\u003e allows a controlled release of water from the cylinder during servicing, maintenance, or decommissioning.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eIs this suitable for any electric water heater, or only ELDOM models?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eIt is a standard \u003cb\u003e1\/2\" BSP, 0.8 MPa brass safety valve\u003c\/b\u003e and will fit any electric storage water heater specified with this thread size and pressure rating, not only ELDOM units. Always check the pressure rating on your existing valve or the heater's data plate before ordering.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #D9EDEA; border-radius: 8px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003csummary style=\"background: #008377CF; color: #ffffff; font-weight: bold; font-size: 15px; padding: 12px 16px; cursor: pointer; list-style: none;\"\u003eWho should install this valve?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 14px 16px; font-size: 14px; color: #333333; line-height: 1.6; background: #FFFFFF;\"\u003eFitting or replacing a water heater safety valve should be carried out by a \u003cb\u003ecompetent person\u003c\/b\u003e following the water heater manufacturer's installation instructions, to ensure correct operation and continued compliance with the appliance's safety requirements.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"AIZO - Quality Heating","offers":[{"title":"Default Title","offer_id":65562479395165,"sku":"Valve0.8mpa","price":13.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/0.8mpapressurereliefvalve-red-release.jpg?v=1786614284","url":"https:\/\/qualityheating.co.uk\/products\/pressure-relief-valve-electric-water-heater-male-thread-x-female-bsp-brass-0-8mpa","provider":"AIZO Quality Heating","version":"1.0","type":"link"}