{"product_id":"polypipe-stainless-steel-ufh-manifold-control-pack-ufch-pump-mixer-valve-set","title":"Polypipe Stainless Steel UFH Manifold Control Pack | UFCH Pump \u0026 Mixer Valve Set","description":"\u003cstyle\u003e\n  .pp-desc * { box-sizing: border-box; }\n  .pp-desc { font-family: inherit; color: inherit; line-height: 1.7; font-size: 16px; }\n  .pp-desc p, .pp-desc li, .pp-desc td, .pp-desc th { font-size: 16px !important; line-height: 1.7; }\n  .pp-desc h2 { font-size: 22px !important; font-weight: 700; color: #1a2a1a; border-bottom: 2px solid #e05c00; padding-bottom: 6px; margin: 2rem 0 1rem; line-height: 1.3; }\n  .pp-desc h3 { font-size: 17px !important; font-weight: 700; color: #1a2a1a; margin: 1.2rem 0 0.4rem; line-height: 1.4; }\n  .pp-desc p { margin: 0 0 1rem; }\n  .pp-desc ul { padding-left: 1.5rem; margin: 0 0 1rem; }\n  .pp-desc ul li { margin-bottom: 0.5rem; }\n  .pp-intro-box { background: #f9f4f0; border-left: 4px solid #e05c00; padding: 1.1rem 1.4rem; border-radius: 0 6px 6px 0; margin-bottom: 1.5rem; }\n  .pp-intro-box p { margin: 0 !important; }\n  .pp-badge { display: inline-block; background: #e05c00; color: #fff; font-size: 13px !important; font-weight: 700; border-radius: 4px; padding: 2px 10px; margin-right: 6px; margin-bottom: 4px; vertical-align: middle; letter-spacing: 0.04em; }\n  .pp-badge.grey { background: #555; }\n  .pp-badge.dark { background: #1a2a1a; }\n  .pp-grid { display: grid; grid-template-columns: repeat(auto-fill, minmax(230px, 1fr)); gap: 0.85rem; margin-bottom: 1.2rem; }\n  .pp-card { background: #f9f9f9; border: 1px solid #ddd; border-radius: 6px; padding: 1rem 1.1rem; line-height: 1.6; }\n  .pp-card strong { display: block; color: #1a2a1a; margin-bottom: 0.35rem; font-size: 16px !important; }\n  .pp-callout { background: #f9f4f0; border-left: 4px solid #e05c00; border-radius: 0 6px 6px 0; padding: 1rem 1.3rem; margin: 1.2rem 0; }\n  .pp-callout p { margin: 0 !important; }\n  .pp-callout h3 { margin-top: 0 !important; color: #1a2a1a; }\n  .pp-stat-bar { background: #1a2a1a; color: #fff; border-radius: 8px; padding: 1.1rem 1.4rem; margin: 1.2rem 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: center; }\n  .pp-stat { text-align: center; }\n  .pp-stat .num { font-size: 26px !important; font-weight: 800; color: #ff8c44; line-height: 1; }\n  .pp-stat .lbl { font-size: 12px !important; color: #ccc; margin-top: 2px; }\n  .pp-spec-table { width: 100%; border-collapse: collapse; margin-bottom: 1.2rem; }\n  .pp-spec-table th { background: #1a2a1a; color: #fff !important; text-align: left; padding: 0.7rem 1rem; font-weight: 600; font-size: 16px !important; }\n  .pp-spec-table td { padding: 0.6rem 1rem; border-bottom: 1px solid #e0e0e0; vertical-align: top; font-size: 16px !important; }\n  .pp-spec-table tr:nth-child(even) td { background: #f5f5f5; }\n  .pp-spec-table td:first-child { font-weight: 600; color: #111; width: 42%; }\n  .pp-inbox-list { list-style: none !important; padding: 0 !important; margin: 0 0 1rem !important; }\n  .pp-inbox-list li { padding: 0.5rem 0 0.5rem 1.8rem !important; border-bottom: 1px solid #ebebeb; position: relative; margin-bottom: 0 !important; font-size: 16px !important; }\n  .pp-inbox-list li::before { content: \"✓\"; position: absolute; left: 0; color: #e05c00; font-weight: 700; }\n  .pp-infobox { background: #fff8e6; border: 1px solid #f0d080; border-radius: 6px; padding: 1rem 1.2rem; margin-top: 1.5rem; color: #5a4a00; line-height: 1.6; font-size: 16px !important; }\n  .pp-faq-item { border-bottom: 1px solid #e0e0e0; padding: 1rem 0; }\n  .pp-faq-item:last-child { border-bottom: none; }\n  .pp-faq-item p { margin: 0.4rem 0 0 !important; }\n  @media (max-width: 600px) {\n    .pp-grid { grid-template-columns: 1fr 1fr; }\n    .pp-spec-table td:first-child { width: auto; }\n    .pp-stat-bar { justify-content: center; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"pp-desc\"\u003e\n\n  \u003cdiv class=\"pp-intro-box\"\u003e\n    \u003cp\u003e\n      \u003cspan class=\"pp-badge\"\u003eUFHSPP1\u003c\/span\u003e\n      \u003cspan class=\"pp-badge grey\"\u003eReplaces PB970055\u003c\/span\u003e\n      \u003cspan class=\"pp-badge dark\"\u003eStainless Steel Manifolds Only\u003c\/span\u003e\n    \u003c\/p\u003e\n    \u003cp style=\"margin-top:0.75rem !important;\"\u003eThe \u003cstrong\u003ePolypipe UFHSPP1 Stainless Steel UFCH Manifold Control Pack\u003c\/strong\u003e is the essential temperature regulation assembly for all Polypipe water underfloor heating systems using stainless steel manifolds. Supplied pre-fabricated and ready to bolt directly onto any Polypipe stainless steel manifold with 210mm port centres, the pack contains everything needed to regulate water temperature between 30°C and 60°C — the correct operating range for underfloor heating circuits. It includes an A-rated energy-efficient EUP pump, a UFCH mixing valve, a pump elbow, and all the adaptors and bends required for a complete assembly. The UFHSPP1 replaces the previous code PB970055 and is the current standard control pack for Polypipe stainless steel manifold installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pp-stat-bar\"\u003e\n    \u003cdiv class=\"pp-stat\"\u003e\n\u003cdiv class=\"num\"\u003e30–60°C\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eWater Temp Range\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"pp-stat\"\u003e\n\u003cdiv class=\"num\"\u003e210mm\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eManifold Centre Spacing\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"pp-stat\"\u003e\n\u003cdiv class=\"num\"\u003eA-Rated\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eEUP Pump\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"pp-stat\"\u003e\n\u003cdiv class=\"num\"\u003ePre-Built\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003eFactory Assembled\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"pp-stat\"\u003e\n\u003cdiv class=\"num\"\u003e351mm\u003c\/div\u003e\n\u003cdiv class=\"lbl\"\u003ePack Length\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat is a UFH Manifold Control Pack?\u003c\/h2\u003e\n  \u003cp\u003eIn a water underfloor heating system, the boiler or heat pump delivers water at a temperature that is typically much higher than what the underfloor heating circuits can safely accept. Central heating systems run at 70–80°C; underfloor heating requires water at 30–60°C maximum, with many systems operating most efficiently at 35–45°C for the majority of the heating season. Without temperature regulation, excessively hot water running through underfloor circuits can damage flooring, cause discomfort, and waste energy.\u003c\/p\u003e\n  \u003cp\u003eThe manifold control pack is the device that blends boiler-temperature water with cooler return water from the circuits — using the UFCH mixing valve — to produce the correct flow temperature for the underfloor system. The EUP pump then circulates this correctly-tempered water through all the circuits connected to the manifold, via the flow meters on each port. The entire assembly sits between the boiler supply and the underfloor manifold, and is a required component of every Polypipe stainless steel manifold installation.\u003c\/p\u003e\n\n  \u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n  \u003cdiv class=\"pp-grid\"\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e🔧 Pre-Fabricated — Ready to Install\u003c\/strong\u003eThe UFHSPP1 arrives factory-assembled. It bolts directly to Polypipe stainless steel manifolds with 210mm port centres — no fabrication or bespoke pipework required. This significantly reduces installation time compared to sourcing and assembling pump, valve, and fittings individually.\u003c\/div\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e🌡️ UFCH Mixing Valve — Precise Temperature Control\u003c\/strong\u003eThe included UFCH thermostatic mixing valve blends high-temperature boiler flow with cooler circuit return water to maintain the correct underfloor heating flow temperature. Set between 30°C and 60°C depending on floor construction and covering. Prevents overheating of sensitive floor finishes such as engineered timber and LVT.\u003c\/div\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e⚡ A-Rated EUP Pump — Energy Efficient Circulation\u003c\/strong\u003eThe pack includes an A-rated, energy-efficient EUP circulator pump — compliant with EU ErP (Energy Related Products) directive requirements. An A-rated pump consumes significantly less electricity than older D or E-rated models, reducing running costs over the life of the heating system. The pump drives heated water through all manifold circuits at the correct pressure and flow rate.\u003c\/div\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e🔩 Complete Fittings Included\u003c\/strong\u003ePump elbow, bends, and all adaptors needed to connect the control pack to the stainless steel manifold assembly are included in the pack. Compatible UFH165 isolation valves (sold separately) allow the control pack to be isolated from the manifold for servicing without draining the entire system.\u003c\/div\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e🏗️ Stainless Steel Compatibility\u003c\/strong\u003eThe UFHSPP1 is designed and supplied exclusively for use with Polypipe's stainless steel push-fit manifold range (PB12752 through PB12761 and the UFH12xxx EC EuroCone series). It is not suitable for use with Polypipe's plastic manifold range — use the appropriate plastic manifold control pack for those installations.\u003c\/div\u003e\n    \u003cdiv class=\"pp-card\"\u003e\n\u003cstrong\u003e📋 Required for System Commissioning\u003c\/strong\u003eFor Polypipe stainless steel manifold installations, the control pack is a required system component. It is included in house pack and zone pack quotations. If you are building up a system from individual components — manifold, isolation valves, control pack, room stats — the UFHSPP1 is the control pack to specify.\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eWhat's in the Pack\u003c\/h2\u003e\n  \u003cul class=\"pp-inbox-list\"\u003e\n    \u003cli\u003eEUP A-rated circulator pump\u003c\/li\u003e\n    \u003cli\u003eUFCH thermostatic mixing valve (blends flow temperature to 30–60°C)\u003c\/li\u003e\n    \u003cli\u003ePump elbow connection\u003c\/li\u003e\n    \u003cli\u003eAll bends and adaptors for connection to Polypipe stainless steel manifolds\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"color:#555; font-size:15px !important;\"\u003e\u003cstrong\u003eSold separately:\u003c\/strong\u003e UFH165 stainless steel isolation valves (1\" pair, required) and UFH170 manifold adaptors (1\"F swivel × 22mm compression, required for 22mm pipework connections). See related products in this range.\u003c\/p\u003e\n\n  \u003ch2\u003eSystem Compatibility\u003c\/h2\u003e\n  \u003cdiv class=\"pp-callout\"\u003e\n    \u003ch3\u003e⚠️ Stainless Steel Manifolds Only\u003c\/h3\u003e\n    \u003cp\u003eThe UFHSPP1 is designed exclusively for use with Polypipe \u003cstrong\u003estainless steel manifolds\u003c\/strong\u003e — including the push-fit PB127xx series and the EuroCone UFH127xxEC series. It is \u003cstrong\u003enot compatible\u003c\/strong\u003e with Polypipe's plastic manifold range (PB123xx series). For plastic manifold installations, specify the appropriate plastic manifold control pack instead. If you are unsure which manifold type your system uses, check the manifold body — stainless steel manifolds are silver\/brushed metal in appearance; plastic manifolds are typically grey or white.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"pp-spec-table\"\u003e\n    \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMPN\u003c\/td\u003e\n\u003ctd\u003eUFHSPP1 (replaces PB970055)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePolypipe\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eStainless steel body with brass fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePack length\u003c\/td\u003e\n\u003ctd\u003e351mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eManifold centre spacing\u003c\/td\u003e\n\u003ctd\u003e210mm (fits all Polypipe stainless steel manifolds)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eWater temperature range\u003c\/td\u003e\n\u003ctd\u003e30°C – 60°C (set via mixing valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003ePump rating\u003c\/td\u003e\n\u003ctd\u003eA-rated EUP compliant circulator\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCompatible manifolds\u003c\/td\u003e\n\u003ctd\u003ePolypipe stainless steel manifold range (PB127xx \/ UFH127xxEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eIsolation valves\u003c\/td\u003e\n\u003ctd\u003eSold separately — UFH165 (stainless steel 1\" pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003ctd\u003eManifold adaptors\u003c\/td\u003e\n\u003ctd\u003eSold separately — UFH170 (1\"F swivel × 22mm compression, pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eInstallation Overview\u003c\/h2\u003e\n  \u003cp\u003eThe UFHSPP1 bolts directly to the assembled stainless steel manifold. The sequence for a complete manifold assembly is as follows: fix the manifold(s) to the wall using the included bracket; attach the UFH165 isolation valves to the flow and return manifold ends; connect the UFHSPP1 control pack to the isolation valves; connect 22mm pipework from the boiler to the inlet connections using UFH170 adaptors if required. Vent the pump and manifold circuits thoroughly before energising. Set the mixing valve to the lowest temperature initially and increase in 5°C increments over the first few days of operation when commissioning solid floor systems — this allows screeded floors to warm up gradually without cracking. For other floor types, set the mixing valve to the system design temperature directly.\u003c\/p\u003e\n\n  \u003cdiv class=\"pp-callout\"\u003e\n    \u003ch3\u003e💡 Commissioning Tip — Solid Floors\u003c\/h3\u003e\n    \u003cp\u003eIf commissioning a solid floor (screeded) system, do not run the system at full temperature immediately. Set the mixing valve to minimum on day 1 and increase by 5°C per day until the system reaches design temperature. This prevents thermal shock cracking in the screed. For all other floor types — overlay, suspended timber, low-profile systems — the system can be run at design temperature from first start-up, after ensuring all air has been fully purged from the circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003cdiv class=\"pp-faq-item\"\u003e\n    \u003ch3\u003eDo I need isolation valves as well, or are they included?\u003c\/h3\u003e\n    \u003cp\u003eIsolation valves are \u003cstrong\u003enot included\u003c\/strong\u003e in the UFHSPP1 pack and must be ordered separately. For stainless steel manifold systems, specify \u003cstrong\u003eUFH165\u003c\/strong\u003e — the Polypipe stainless steel 1\" isolation valve pair. These are fitted between the manifold and the control pack and allow the control pack to be isolated for servicing. Without isolation valves, the entire system would need to be drained to remove the control pack.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"pp-faq-item\"\u003e\n    \u003ch3\u003eWhat adaptors do I need to connect the control pack to the boiler pipework?\u003c\/h3\u003e\n    \u003cp\u003eIf your boiler flow and return are in 22mm pipework — as is standard for most domestic systems — you will need the \u003cstrong\u003eUFH170 manifold adaptor pair\u003c\/strong\u003e (1\" female swivel × 22mm compression), also sold separately. These adapt the 1\" BSP connections on the isolation valves to 22mm compression for connection to copper or barrier pipe flow and return mains.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"pp-faq-item\"\u003e\n    \u003ch3\u003eCan I use this control pack with a plastic Polypipe manifold?\u003c\/h3\u003e\n    \u003cp\u003eNo. The UFHSPP1 is designed exclusively for stainless steel manifolds. The port spacing, connection geometry, and materials are specific to the stainless steel manifold range. Polypipe produces a separate control pack for use with their plastic manifold range — please select the correct product for your manifold type.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"pp-faq-item\"\u003e\n    \u003ch3\u003eWhat temperature should I set the mixing valve to?\u003c\/h3\u003e\n    \u003cp\u003eThe correct setting depends on your floor construction and floor covering. As a general guide: solid screeded floors with tiles — 45–50°C; solid screeded floors with engineered timber or LVT — 35–40°C; overlay and low-profile systems — 45–55°C; suspended timber systems — 45–55°C. Always verify with your UFH system design documentation. For solid floors, start at the minimum setting and increase by 5°C per day during the first week of operation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"pp-faq-item\"\u003e\n    \u003ch3\u003eIs the UFHSPP1 the same as the PB970055?\u003c\/h3\u003e\n    \u003cp\u003eYes — the UFHSPP1 is the current product code and directly replaces the previous PB970055. The function, specification, and compatibility are the same. If you are replacing or matching a PB970055, the UFHSPP1 is the correct current replacement.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"pp-infobox\"\u003e\n    \u003cstrong\u003e🔗 Complete the manifold assembly:\u003c\/strong\u003e The UFHSPP1 control pack is typically ordered alongside the stainless steel manifold (PB127xx or UFH127xxEC series), \u003cstrong\u003eUFH165\u003c\/strong\u003e isolation valves (1\" pair), and \u003cstrong\u003eUFH170\u003c\/strong\u003e manifold adaptors (1\"F × 22mm, pair). For zone valve control, Polypipe zone valves connect to the flow pipework downstream of the control pack.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Polypipe","offers":[{"title":"Default Title","offer_id":63633169514845,"sku":"UFHSPP1","price":450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/PolypipeStainlessSteelUFHManifoldControlPackUFCHPump_MixerValveSet.webp?v=1772125957","url":"https:\/\/qualityheating.co.uk\/products\/polypipe-stainless-steel-ufh-manifold-control-pack-ufch-pump-mixer-valve-set","provider":"AIZO Quality Heating","version":"1.0","type":"link"}