{"product_id":"panasonic-aquarea-t-cap-monobloc-j-generation-r32-heat-pump-9-12-16kw","title":"Panasonic Aquarea T-CAP Monobloc J Generation R32 Heat Pump — 9\/12\/16kW","description":"\u003c!-- SEO Product Name: Panasonic Aquarea T-CAP Monobloc J Generation R32 Heat Pump — 9\/12\/16kW --\u003e\n\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#222;max-width:900px;margin:0 auto;line-height:1.55;\"\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe \u003cstrong\u003ePanasonic Aquarea T-CAP Monobloc J Generation\u003c\/strong\u003e is Panasonic's cold-climate R32 monobloc range, built around \u003cstrong\u003eT-CAP (Total Capacity) technology\u003c\/strong\u003e that sustains full rated output down to \u003cstrong\u003e-15°C ambient\u003c\/strong\u003e — no capacity drop-off, no reliance on backup heat, even on the coldest UK days. Available in \u003cstrong\u003e9 kW and 12 kW single-phase\u003c\/strong\u003e, and \u003cstrong\u003e16 kW three-phase\u003c\/strong\u003e. Panasonic's own EN14511 data shows all three variants hold their \u003cstrong\u003efull nameplate output at -15°C \/ W45°C\u003c\/strong\u003e — a genuinely different proposition to a standard monobloc that derates in cold weather.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin:18px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003e9–16 kW\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eOutput range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003eR32\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eRefrigerant\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003eT-CAP\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eCold-climate tech\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003eFull Output at -15°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eT-CAP guarantee\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003e1 or 3-Phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eElectrical supply\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px;min-width:120px;background:#008377CF;color:#fff;padding:14px 10px;text-align:center;border-radius:6px;\"\u003e\n\u003cdiv style=\"font-size:22px;font-weight:700;line-height:1.1;\"\u003e60°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;margin-top:4px;opacity:0.95;letter-spacing:0.3px;text-transform:uppercase;\"\u003eMax hydraulic output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F3F1;border-left:4px solid #008377;padding:14px 16px;margin:16px 0;border-radius:0 4px 4px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:4px;\"\u003eBUS grant eligible\u003c\/div\u003e\n\u003cdiv\u003ePanasonic Aquarea monobloc heat pumps are eligible for the UK \u003cstrong\u003eBoiler Upgrade Scheme grant\u003c\/strong\u003e when installed by an MCS-certified installer in an eligible property.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FBEAE9;border-left:4px solid #B3261E;padding:14px 16px;margin:16px 0;border-radius:0 4px 4px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#B3261E;margin-bottom:4px;\"\u003eMCS-certified installer required\u003c\/div\u003e\n\u003cdiv\u003eTo claim the BUS grant and validate full Panasonic manufacturer warranty, this heat pump must be installed and commissioned by an \u003cstrong\u003eMCS-certified heat pump installer\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003eChoose your capacity\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14.5px;margin:8px 0;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"background:#008377CF;color:#fff;padding:9px 12px;border:1px solid #008377;text-align:left;font-weight:700;\"\u003eNameplate output\u003c\/th\u003e\n\u003cth style=\"background:#008377CF;color:#fff;padding:9px 12px;border:1px solid #008377;text-align:left;font-weight:700;\"\u003eElectrical supply\u003c\/th\u003e\n\u003cth style=\"background:#008377CF;color:#fff;padding:9px 12px;border:1px solid #008377;text-align:left;font-weight:700;\"\u003eDelivered capacity (A-15°C \/ W45°C)\u003c\/th\u003e\n\u003cth style=\"background:#008377CF;color:#fff;padding:9px 12px;border:1px solid #008377;text-align:left;font-weight:700;\"\u003eModel code\u003c\/th\u003e\n\u003cth style=\"background:#008377CF;color:#fff;padding:9px 12px;border:1px solid #008377;text-align:left;font-weight:700;\"\u003eTypical property fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e9 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e1-phase\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e9 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eWH-MXC09J3E5\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e3 to 4 bedroom homes needing reliable cold-weather output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e12 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e1-phase\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e12 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eWH-MXC12J6E5\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eLarger 4 to 5 bedroom homes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e16 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e3-phase\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e16 kW\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eWH-MXC16J9E8\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eVery large detached \/ light commercial, 3-phase supply properties\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"background:#E6F3F1;border-left:4px solid #008377;padding:14px 16px;margin:16px 0;border-radius:0 4px 4px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:4px;\"\u003eWhat T-CAP actually means\u003c\/div\u003e\n\u003cdiv\u003eMost air source heat pumps lose heating capacity as the outside temperature falls — a 9 kW unit at +7°C might only deliver 6–7 kW at -7°C. \u003cstrong\u003eT-CAP holds the full nameplate output all the way down to -15°C ambient\u003c\/strong\u003e, so the kW you specify is the kW you get on the coldest night of the year — removing the guesswork (and the temptation to oversize) from sizing for UK winter design conditions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:14px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003eT-CAP — full capacity to -15°C\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003eDelivers \u003cstrong\u003erated nameplate output at -15°C ambient\u003c\/strong\u003e with a 45°C flow temperature — no capacity fade on cold days, unlike standard (non-T-CAP) monobloc units.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003eAquarea Smart Control\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003eBuilt-in Wi-Fi-ready platform via Aquarea Smart Cloud — schedule, monitor and view energy data through the free smartphone app (Wi-Fi adapter sold separately).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003eR32 refrigerant\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003eLower GWP than legacy R410A units. Sealed monobloc circuit with no on-site F-Gas brazing at install.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003e60°C hydraulic output\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003eReaches 60°C flow temperature — suits a broad range of UK retrofit radiator setups without emitter replacement.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003eModulating inverter\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003eDC inverter compressor modulates output continuously across the full range, maintaining efficiency on milder days as well as at the T-CAP design condition.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;min-width:240px;background:#fff;border:1px solid #E5E7EB;border-top:3px solid #008377CF;padding:14px 16px;border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#008377;margin-bottom:6px;\"\u003eSingle or three-phase\u003c\/div\u003e\n\u003cdiv style=\"font-size:14.5px;\"\u003e9 and 12 kW available single-phase for typical domestic supplies; 16 kW available three-phase for larger properties or where a three-phase supply already exists.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003ePlatform specification (all variants)\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14.5px;margin:8px 0;\"\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003ePanasonic Aquarea T-CAP Monobloc J Generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eR32 monobloc air source heat pump with T-CAP cold-climate technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eAvailable nameplate capacities\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e9 kW \/ 12 kW \/ 16 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eModel codes\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eWH-MXC09J3E5 (1-phase) \/ WH-MXC12J6E5 (1-phase) \/ WH-MXC16J9E8 (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eR32 (sealed factory charge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eT-CAP rated condition\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eFull nameplate capacity delivered at A-15°C \/ W45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eMaximum hydraulic output temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eElectrical supply\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003e1-phase (9\/12 kW) or 3-phase (16 kW), 230\/400V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FAFA;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eMCS certified (EN14511), BUS grant eligible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#FFFFFF;\"\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;font-weight:600;width:42%;\"\u003eSmart connectivity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #E5E7EB;\"\u003eAquarea Smart Cloud \/ Comfort Cloud (Wi-Fi adapter sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003eWhat's in the box (every variant)\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;margin:8px 0;\"\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003ePanasonic Aquarea T-CAP Monobloc J Generation outdoor unit (capacity per selected variant)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eWired remote controller\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eBuilt-in magnetic water filter, flow meter, automatic air purge valve\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eManufacturer installation and commissioning documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003eWhat you'll also need (sold separately)\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;margin:8px 0;\"\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eDHW cylinder (heat-pump-suitable, indirect coil sized for low flow temperature)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eOutdoor wall bracket or floor stand\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eAnti-freeze valves on primary flow and return\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eMagnetic system filter on the primary return (in addition to the outdoor unit's built-in filter)\u003c\/li\u003e\n\u003cli style=\"margin-bottom:5px;\"\u003eCZ-TAW1C or CZ-TAW2 Wi-Fi adapter for full smartphone app access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color:#008377;font-size:18px;margin:24px 0 10px 0;padding-bottom:6px;border-bottom:2px solid #008377CF;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #E5E7EB;border-radius:4px;margin:8px 0;overflow:hidden;\"\u003e\u003csummary style=\"cursor:pointer;background:#008377CF;color:#fff;padding:10px 14px;font-weight:600;list-style:none;\"\u003eWhich kW should I choose?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 16px;background:#FFFFFF;\"\u003eChoose the variant that matches your \u003cstrong\u003ecalculated heat loss\u003c\/strong\u003e at your local winter design temperature. As a rough guide: 9 kW for 3–4 bed homes needing reliable cold-weather output; 12 kW for larger 4–5 bed homes; 16 kW for very large or light-commercial properties, or where a 3-phase supply already exists. Because T-CAP holds full capacity down to -15°C, you generally don't need to oversize for cold-weather margin the way you might with a standard monobloc.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #E5E7EB;border-radius:4px;margin:8px 0;overflow:hidden;\"\u003e\u003csummary style=\"cursor:pointer;background:#008377CF;color:#fff;padding:10px 14px;font-weight:600;list-style:none;\"\u003eWhat's the difference between T-CAP and the standard J Generation?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 16px;background:#FFFFFF;\"\u003eThe standard \u003cstrong\u003eJ Generation\u003c\/strong\u003e (5\/7\/9 kW) loses some capacity as it gets colder and the flow temperature needed rises — see our J Generation listing. \u003cstrong\u003eT-CAP\u003c\/strong\u003e is specifically engineered to hold \u003cstrong\u003efull rated output all the way to -15°C ambient\u003c\/strong\u003e, making it the better choice for larger properties, higher heat-loss buildings, or anywhere reliable output on the coldest days matters most.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #E5E7EB;border-radius:4px;margin:8px 0;overflow:hidden;\"\u003e\u003csummary style=\"cursor:pointer;background:#008377CF;color:#fff;padding:10px 14px;font-weight:600;list-style:none;\"\u003eCan I choose 1-phase or 3-phase?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 16px;background:#FFFFFF;\"\u003eThe 9 kW and 12 kW variants are \u003cstrong\u003e1-phase only\u003c\/strong\u003e. The 16 kW variant is \u003cstrong\u003e3-phase only\u003c\/strong\u003e — check your property's electrical supply before ordering.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #E5E7EB;border-radius:4px;margin:8px 0;overflow:hidden;\"\u003e\u003csummary style=\"cursor:pointer;background:#008377CF;color:#fff;padding:10px 14px;font-weight:600;list-style:none;\"\u003eDoes this need a separate Wi-Fi module?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 16px;background:#FFFFFF;\"\u003eYes — the CZ-TAW1C or CZ-TAW2 Wi-Fi adapter is sold separately for full smartphone app access. The unit ships with a standard wired remote controller.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #E5E7EB;border-radius:4px;margin:8px 0;overflow:hidden;\"\u003e\u003csummary style=\"cursor:pointer;background:#008377CF;color:#fff;padding:10px 14px;font-weight:600;list-style:none;\"\u003eDo I need to be MCS-registered to install this?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 16px;background:#FFFFFF;\"\u003eThe Aquarea can be installed by any competent engineer, but the Boiler Upgrade Scheme grant requires an \u003cstrong\u003eMCS-certified installer\u003c\/strong\u003e. Quality Heating can introduce you to trade partners if needed.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Panasonic","offers":[{"title":"9kW 1-phase","offer_id":65719262708061,"sku":"WH-MXC09J3E5","price":4500.0,"currency_code":"GBP","in_stock":true},{"title":"12kW 1-phase","offer_id":65719262740829,"sku":"WH-MXC12J6E5","price":5500.0,"currency_code":"GBP","in_stock":true},{"title":"16kW 3-phase","offer_id":65719262773597,"sku":"WH-MXC16J9E8","price":7770.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/PanasonicAquareaT-CAPMonoblocJGenerationR32HeatPump.jpg?v=1787899378","url":"https:\/\/qualityheating.co.uk\/products\/panasonic-aquarea-t-cap-monobloc-j-generation-r32-heat-pump-9-12-16kw","provider":"AIZO Quality Heating","version":"1.0","type":"link"}