{"product_id":"panasonic-5-2kw-r32-free-multi-z-outdoor-unit-cu-3z52cbe-3-connections","title":"Panasonic 5.2kW R32 Free Multi Z Outdoor Unit CU-3Z52CBE - 3 Connections","description":"\u003c!-- SEO Product Name: Panasonic 5.2kW R32 Free Multi Z Outdoor Unit CU-3Z52CBE - 3 Connections --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\n    \u003cdiv style=\"background:#FDECEC; border:2px solid #D32F2F; border-radius:6px; padding:18px 20px; margin:0 0 24px 0;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#D32F2F; font-size:15px; margin-bottom:10px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eF-Gas Certification Required\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B; margin-bottom:14px;\"\u003ePlease note: We are legally required to verify your F-Gas certification before supplying restricted refrigerants. Orders without valid certification will not be processed.\u003c\/div\u003e\n        \u003ca href=\"https:\/\/zfrmz.eu\/T1RXKOJ4maQg2qjKx0FO\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block; background:#008377CF; color:#FFFFFF; font-weight:700; padding:11px 22px; border-radius:5px; text-decoration:none; font-size:14px;\"\u003eSubmit Your F-Gas Certification\u003c\/a\u003e\n    \u003c\/div\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eThe \u003cstrong\u003ePanasonic CU-3Z52CBE\u003c\/strong\u003e is a \u003cstrong\u003e3-connection Free Multi Z outdoor condensing unit\u003c\/strong\u003e, built to run up to three independently controlled indoor units from a single external condenser. It uses the \u003cstrong\u003eR32 refrigerant\u003c\/strong\u003e and an inverter-driven rotary compressor to deliver flexible, room-by-room heating and cooling without the need to install a separate outdoor unit for every room.\u003c\/p\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eRated at \u003cstrong\u003e5.2kW nominal cooling\u003c\/strong\u003e and \u003cstrong\u003e6.8kW nominal heating\u003c\/strong\u003e, the CU-3Z52CBE supports a combined indoor capacity range of \u003cstrong\u003e4.5kW to 9.5kW\u003c\/strong\u003e, and reaches \u003cstrong\u003eA+++ SEER efficiency\u003c\/strong\u003e, making it a strong entry point into Panasonic's Free Multi Z range for smaller homes and apartments needing three zones.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 26px -4px;\"\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e5.2 kW\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eNominal Cooling\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e6.8 kW\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eNominal Heating\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e3\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eIndoor Connections\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eA+++\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eSEER Rating\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eR32\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eRefrigerant\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e-15°C\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMin Heating Temp\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#D32F2F; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eImportant: F-Gas Qualified Installation Required\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eThis unit is charged with \u003cstrong\u003eR32\u003c\/strong\u003e, a fluorinated greenhouse gas covered by F-Gas Regulations. Installation, commissioning, and any refrigerant handling must be carried out by an \u003cstrong\u003eF-Gas certified engineer\u003c\/strong\u003e. See the certification form above before ordering.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#E0942A; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003ePlease Note: Indoor Capacity Range and Pipe Reducers\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eTwo indoor units from the wall-mounted TZ range (16–50kW capacity codes) must be connected for the system to operate correctly, and the combined nominal cooling capacity of all connected indoor units must fall within the \u003cstrong\u003e4.5kW–9.5kW\u003c\/strong\u003e connectable range. Some larger TZ indoor unit sizes require the \u003cstrong\u003eCZ-MA1PA pipe reducer\u003c\/strong\u003e accessory to connect — confirm pipe sizing against the specific indoor units selected before ordering.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eGood to Know: Minimum Two Indoor Units Must Be Connected\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eThe CU-3Z52CBE is designed to run \u003cstrong\u003e2 or 3 indoor units\u003c\/strong\u003e — at least two must be connected for the system to operate correctly. Indoor unit sizes can be mixed and matched, but total connected capacity cannot exceed the outdoor unit's maximum.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 24px -4px;\"\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eThree Independent Zones From One Outdoor Unit\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eA single compact condenser drives \u003cstrong\u003eup to three rooms\u003c\/strong\u003e with individual temperature control on each, cutting down on external wall space, pipework runs, and visible outdoor equipment compared to installing three single-split systems.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eInverter-Driven Rotary Compressor\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eThe \u003cstrong\u003einverter compressor\u003c\/strong\u003e modulates output to match real-time demand across all connected rooms rather than cycling on and off, which improves comfort, reduces electricity use, and lowers operating noise.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eA+++ SEER Efficiency\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eAchieves an \u003cstrong\u003eSEER rating of 8.70 (A+++)\u003c\/strong\u003e, placing it at the top of the current European energy label scale for cooling efficiency.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eR32 Refrigerant for Lower Environmental Impact\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eR32 has a \u003cstrong\u003elower global warming potential\u003c\/strong\u003e than the R410A refrigerant it replaces, while also improving system efficiency — helping the unit meet current and future F-Gas phase-down requirements.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eWide Heating Operating Range\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eRated to operate in heating mode down to \u003cstrong\u003e-15°C outdoor ambient\u003c\/strong\u003e, making it a genuine year-round heat pump solution for UK winters, not just a summer air conditioning unit.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 45%; min-width:230px; background:#E6F4F3; border-radius:6px; padding:16px 18px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; font-size:15px; margin-bottom:6px;\"\u003eCompact Footprint For Flexible Siting\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eAt \u003cstrong\u003e795mm (H) x 875mm (W) x 320mm (D)\u003c\/strong\u003e, the unit's compact dimensions make it easier to site on balconies, flat roofs, or against garden walls where space for outdoor plant is limited.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 24px 0; border:1px solid #D9EDEA;\"\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003ePerformance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCooling Capacity (Nominal)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e5.2 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1.80 – 7.30 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eHeating Capacity (Nominal)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e6.8 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1.60 – 8.50 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eIndoor Nominal Capacity Range (Min–Max)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e4.5 – 9.5 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eMinimum Indoor Units Connected\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eMaximum Indoor Units Connected\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e3\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003eEfficiency\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eEER (Nominal)\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e4.77 W\/W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCOP (Nominal)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e4.93 W\/W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eSEER\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e8.70 (A+++)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eSCOP\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e4.20 – 4.70 (A++)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e230V, 1-phase, 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eRunning Current – Cooling\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e6.10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eMaximum Current\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e15.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003eSound\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eOutdoor Sound Pressure – Cooling (Hi)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e47 dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eOutdoor Sound Pressure – Heating (Hi)\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e48 dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003ePhysical \u0026amp; Refrigerant\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e795 x 875 x 320 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e61 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eRefrigerant\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eR32\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eRefrigerant Charge\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1.92 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCO₂ Equivalent\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1.296 T\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003ePipe Diameter – Liquid\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1\/4\" (6.35 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003ePipe Diameter – Gas\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e3\/8\" (9.52 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eTotal Pipe Length Range\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e6 – 50 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003ePipe Length Range to One Unit\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e3 – 25 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eElevation Difference (In\/Out)\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e15 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 14px; font-size:13px; letter-spacing:0.05em; text-transform:uppercase;\"\u003eOperating Range\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCooling – Outdoor Ambient\u003c\/td\u003e\n        \u003ctd style=\"background:#F2FAF9; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e-10°C to +46°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003ctr\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; font-weight:600; color:#333333; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eHeating – Outdoor Ambient\u003c\/td\u003e\n        \u003ctd style=\"background:#FFFFFF; padding:9px 14px; color:#222222; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e-15°C to +24°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 24px 0; border:1px solid #D9EDEA;\"\u003e\n        \u003ctr\u003e\n\u003cth style=\"background:#008377CF; color:#FFFFFF; padding:10px 12px; font-size:13px; text-align:left; letter-spacing:0.03em;\"\u003eIndoor Unit Capacity Codes\u003c\/th\u003e\n\u003cth style=\"background:#008377CF; color:#FFFFFF; padding:10px 12px; font-size:13px; text-align:left; letter-spacing:0.03em;\"\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F2FAF9; padding:9px 12px; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e16, 20, 25, 35\u003c\/td\u003e\n\u003ctd style=\"background:#F2FAF9; padding:9px 12px; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eStandard connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 12px; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e42, 50\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 12px; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eRequires CZ-MA1PA pipe reducer\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/table\u003e\n\u003cdiv style=\"margin:8px 0 4px 0;\"\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eHow many indoor units can I connect to the CU-3Z52CBE?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eBetween \u003cstrong\u003e2 and 3 indoor units\u003c\/strong\u003e can be connected. At least two must be connected for the system to run — it cannot be operated with only one indoor unit fitted.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eWhat indoor unit types are compatible with this outdoor unit?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eThe CU-3Z52CBE supports Panasonic's wall-mounted TZ super-compact range, along with other Free Multi Z compatible indoor unit types, allowing different room types to use different indoor styles on the same outdoor unit.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eDoes this outdoor unit need an F-Gas certified installer?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eYes. The unit is charged with \u003cstrong\u003eR32 refrigerant\u003c\/strong\u003e, which falls under F-Gas Regulations. Installation and any refrigerant work must be carried out by an installer holding valid F-Gas certification, which we verify before shipment.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eWhat is the maximum total indoor capacity I can connect?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eThe combined nominal cooling capacity of all connected indoor units must fall between \u003cstrong\u003e4.5kW and 9.5kW\u003c\/strong\u003e. Exceeding this range is not supported by the manufacturer.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eDo all TZ indoor unit sizes connect directly?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eMost do, but the larger 42 and 50 capacity-code TZ indoor units require the \u003cstrong\u003eCZ-MA1PA pipe reducer\u003c\/strong\u003e accessory to connect to this outdoor unit. Confirm indoor unit sizing before ordering.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"margin:0 0 10px 0; border:1px solid #D9EDEA; border-radius:5px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 16px; cursor:pointer; font-size:14.5px; list-style:none;\"\u003eCan this unit provide heating in cold UK winters?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.65;\"\u003eYes. The CU-3Z52CBE is rated to operate in heating mode down to \u003cstrong\u003e-15°C outdoor ambient temperature\u003c\/strong\u003e, making it suitable as a genuine year-round heat pump rather than a cooling-only summer unit.\u003c\/div\u003e\n        \u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Panasonic","offers":[{"title":"Default Title","offer_id":65625737527645,"sku":"CU-3Z52CBE","price":1450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Panasonic5.2kWR32FreeMultiZOutdoorUnit_ad7103ff-3c6e-404c-8ac6-35de9e198967.jpg?v=1787151251","url":"https:\/\/qualityheating.co.uk\/products\/panasonic-5-2kw-r32-free-multi-z-outdoor-unit-cu-3z52cbe-3-connections","provider":"AIZO Quality Heating","version":"1.0","type":"link"}