{"product_id":"navien-ncb500-18kw-system-boiler","title":"Navien NCB500 18kW System Boiler","description":"\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; font-family:Arial, Helvetica, sans-serif; color:#222;\"\u003e\n\u003cdiv style=\"line-height:1.65;color:#222;margin-bottom:20px;\"\u003eThe \u003cstrong\u003eNavien NCB500-18K\u003c\/strong\u003e is a wall-hung, room-sealed gas condensing \u003cstrong\u003esystem boiler\u003c\/strong\u003e rated at 18kW, designed to work with a separate hot water cylinder for properties with multiple bathrooms or higher simultaneous hot water demand. Built around a \u003cstrong\u003epremium stainless steel heat exchanger\u003c\/strong\u003e, the NCB500 fits comfortably inside a standard kitchen or airing cupboard while delivering \u003cstrong\u003efully modulating\u003c\/strong\u003e output and a market-leading \u003cstrong\u003e10-year parts and labour warranty\u003c\/strong\u003e as standard.\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin:18px 0 26px;\"\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e18kW\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eHeat Output\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e93%\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eErP Efficiency (A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e104.6%\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eFull-Load Efficiency (50\/30°C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e6:1\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eModulation Ratio\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e10 yrs\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eParts \u0026amp; Labour Warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e29kg\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eLift Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fdecea;border-left:5px solid #c0392b;border-radius:0 8px 8px 0;padding:14px 18px;margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#8a1f13;font-size:14px;margin-bottom:5px;\"\u003eGas Safe Registration Required\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eInstallation, commissioning and servicing of this boiler must be carried out by a \u003cstrong\u003eGas Safe registered engineer\u003c\/strong\u003e. A Benchmark commissioning checklist must be completed and left with the end user, and the flue must be positioned in accordance with the clearances set out in the manufacturer's installation and operation manual.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff8e6;border-left:5px solid #b8860b;border-radius:0 8px 8px 0;padding:14px 18px;margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#7a5900;font-size:14px;margin-bottom:5px;\"\u003eSystem Boiler — Cylinder Required Separately\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eThis is a \u003cstrong\u003esystem boiler\u003c\/strong\u003e, not a combi. It requires a separate unvented or vented hot water cylinder to store and deliver domestic hot water, which is not included in this listing. An LPG conversion kit is included in the boiler's packaging for field conversion by a suitably qualified Gas Safe engineer.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eWhy This Boiler\u003c\/div\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:18px 0 26px;\"\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003ePremium Stainless Steel Heat Exchanger\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eOffers \u003cstrong\u003esuperior resistance to corrosion and wear\u003c\/strong\u003e compared with traditional aluminium components, translating into lower maintenance costs and a longer working life.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eFully Modulating Technology\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eThe burner automatically adjusts its output across a \u003cstrong\u003e6:1 turndown ratio\u003c\/strong\u003e to match real-time heating demand, avoiding the short-cycling that wastes gas and wears components on less flexible boilers.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003e10-Year Warranty as Standard\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eNavien back the NCB500 with a \u003cstrong\u003e10-year parts and labour warranty\u003c\/strong\u003e included as standard on every installation, without needing separate registration steps.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eCompact Cupboard-Fit Design\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eAt 395 x 283 x 680mm, the NCB500 is compact enough to fit into a standard kitchen or airing cupboard, easing installation in space-constrained properties.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eErP A+ with Smart Plus\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003ePaired with the Navien Smart Plus control pack, system efficiency rises from \u003cstrong\u003eErP A (93%) to ErP A+ (98%)\u003c\/strong\u003e, thanks to weather forecasting and geofencing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eBuilt-In Smart Control Connector\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eA dedicated connector for the Navien Smart Room Controller is built into the back of the front panel, so no separate terminal wiring is required when adding smart controls.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eTechnical Specification\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto;margin:18px 0 26px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eArticle number\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003ePNCB5000019L001 (NCB500-18K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eBoiler type\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eWall-hung, room-sealed, fan-assisted condensing system boiler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eFuel type\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eNatural gas (LPG conversion kit included, field conversion required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e395 x 283 x 680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eGuarantee\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e10 years parts and labour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003eHeating Performance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eHeat input range\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e3.2 – 18.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eHeat output range (80\/60°C)\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e3.1 – 18.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eCondensing heat output range (50\/30°C)\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e3.4 – 19.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eFull-load efficiency, Max output (50\/30°C, condensing)\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e104.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eModulation (max\/min)\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e6:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eMax. heating operating pressure\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eMax. heating temperature\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eAdjustable heating temperature range\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e40 – 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003ePerformance \u0026amp; Emissions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eErP efficiency\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eA (93%) — A+ (98%) with Smart Plus control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eLift weight\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003eFlue\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eFlue diameter\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eCoaxial 60\/100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eMax. horizontal coaxial flue length\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eMax. vertical coaxial flue length\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"margin:18px 0 10px;\"\u003e\n\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eDoes this boiler include a hot water cylinder?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eNo. As a system boiler, the NCB500-18K requires a separate hot water cylinder to store and deliver domestic hot water. Cylinders are sold separately.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eCan I run this boiler on LPG?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eAn LPG conversion kit is included in the boiler's packaging as standard, but the boiler ships configured for natural gas. Conversion must be carried out by a Gas Safe registered engineer holding the appropriate LPG qualification.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eWhat size property is the NCB500-18K suitable for?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eWith an 18kW output, the NCB500-18K suits small to medium properties, subject to a proper heat loss calculation.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eDoes this boiler support smart heating controls?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eYes. The NCB500 has a dedicated built-in connector for Navien's Smart Room Controller, and is 3-zone ready when combined with the separately available Smart Plus control pack.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eCan I install this boiler myself?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eNo. UK law requires that all gas boiler installation, commissioning and servicing work is carried out by a Gas Safe registered engineer.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Navien","offers":[{"title":"Default Title","offer_id":65142760538461,"sku":"PNCB5000019L001","price":995.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/NavienSystemBoiler.jpg?v=1783091825","url":"https:\/\/qualityheating.co.uk\/products\/navien-ncb500-18kw-system-boiler","provider":"AIZO Quality Heating","version":"1.0","type":"link"}