{"product_id":"matt-e-single-phase-ev-charger-monitoring-protection-device-with-terminals-white","title":"matt:e Single Phase EV Charger Monitoring \u0026 Protection Device with Terminals - White","description":"\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; font-family:Arial, Helvetica, sans-serif; color:#222;\"\u003e\n\u003cp style=\"margin:0 0 14px 0; line-height:1.6; color:#222;\"\u003eThe \u003cb\u003ematt:e SP-EVCP-T(W)\u003c\/b\u003e is a single-phase EV charger connection centre providing \u003cb\u003ebuilt-in PEN fault protection\u003c\/b\u003e for residential electric vehicle charge point installations. It allows an EV charger to be safely connected to a PME (Protective Multiple Earthing) supply \u003cb\u003ewithout the need for earth electrodes\u003c\/b\u003e, removing the disruptive groundworks and risk of striking buried services that earth rod installation typically involves.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0; line-height:1.6; color:#222;\"\u003eFitted with three incoming terminals (the 'T' variant), this unit continuously monitors the incoming supply voltage and automatically disconnects the EV charger, including the CPC, if a PEN fault or other supply anomaly is detected, protecting both the vehicle and the property's electrical installation.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e32A\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eMaximum Load\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e230V\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eSingle Phase Input\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eIP2X\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eIngress Protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3 Years\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eParts Warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e6.0mm²\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eMax Terminal Capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 140px; background:#008377CF; color:#ffffff; border-radius:8px; padding:16px 10px; text-align:center; min-width:140px;\"\u003e\n\u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e~3kg\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px; margin-top:6px; opacity:0.92;\"\u003eUnit Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FDECEC; border-left:4px solid #D93025; border-radius:4px; padding:14px 16px; margin:16px 0; line-height:1.6; color:#222;\"\u003e\n\u003cb\u003eInstaller requirement:\u003c\/b\u003e This product must be installed by a competent person in accordance with the \u003cb\u003eIET Wiring Regulations, BS 7671 (18th Edition or later)\u003c\/b\u003e, and any relevant Building Regulations. All relevant supplies must be fully isolated or disconnected before commencing installation or removing the enclosure cover, as the unit carries a live mains supply (230V or higher) once installed.\u003c\/div\u003e\n\u003cdiv style=\"background:#FFF6E5; border-left:4px solid #B25E00; border-radius:4px; padding:14px 16px; margin:16px 0; line-height:1.6; color:#222;\"\u003e\n\u003cb\u003eSingle-phase PME only:\u003c\/b\u003e The SP-EVCP-T(W) is designed exclusively for domestic dwellings with a \u003cb\u003esingle-phase PME power supply\u003c\/b\u003e and is not suitable for three-phase supplies. It must be connected via the Consumer Distribution Board or 'Garage Board' with a suitable protective device (the 'R' variant, sold separately, is the only version rated for direct connection to meter tails).\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:14px; margin:20px 0;\"\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eBuilt-In matt:e PEN Fault Technology\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eAn electronic detection circuit continuously monitors the incoming supply. On detecting a fault condition sustained for 4 seconds, the circuit de-energises the contactor, disconnecting Line, Neutral, and CPC from the load, isolating the EV charger from a compromised PME supply.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eNo Earth Electrode Required\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eBy eliminating the need for a dedicated earth rod, the SP-EVCP-T(W) avoids costly groundworks and removes the risk of striking buried services during installation, a common practical barrier to PME-based EV charger installations.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eThree-Pole Certified Contactor\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eThe internal isolation contactor is certified to \u003cb\u003eBS EN 60947-4-1\u003c\/b\u003e and complies with the requirements of BS 7671 18th Edition, providing a robust switching mechanism for repeated fault-driven disconnection cycles over the unit's service life.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eWire-In, Wire-Out Simplicity\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eThe 'T' variant provides three incoming terminals ahead of the contactor, allowing a straightforward connection from the distribution board and out to the charger's L, E, and N terminals, without additional protective devices built into this specific unit.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eAutomatic Recovery Logic\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eOnce a fault is cleared, the unit does not reconnect immediately. The monitored supply must remain stable and within correct limits for a period of 3 minutes before the contactor re-energises, preventing nuisance cycling on a marginal or intermittent fault.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px; flex:1 1 260px; min-width:260px;\"\u003e\n\u003cdiv style=\"color:#008377CF; font-weight:700; margin-bottom:8px; font-size:15px;\"\u003eDual-Colour Status Indication\u003c\/div\u003e\n\u003cdiv style=\"line-height:1.6; color:#222; font-size:14px;\"\u003eA red\/green LED gives a real-time visual status of the unit, distinguishing normal operation from over-current, under-voltage, over-voltage, DC detection, and internal error states, supporting faster fault diagnosis on site.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0; font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; font-size:14px;\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eSingle Phase Voltage Monitoring and Protection Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e230V, 50Hz (Single Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eMaximum Load\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e13VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eIncoming Terminal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e0.5mm² - 6.0mm² (1.3Nm tightening torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eOutgoing Contactor Cable Size\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e2.5mm² - 10.0mm² (2.3Nm tightening torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; font-size:14px;\"\u003ePhysical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eColour\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eMild Steel, Powder Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e169mm x 182mm x 111mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eApproximately 3kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eCable Entry\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eBottom, 2 x 20mm knockouts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e5°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#ffffff; font-weight:700; padding:10px 14px; font-size:14px;\"\u003eCompliance \u0026amp; Warranty\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eContactor Standard\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eBS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eWiring Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eBS 7671 (18th Edition or later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eLow Voltage Directive\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003e3 years parts (from date of purchase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F7FBFA;\"\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#333; width:45%;\"\u003eCountry of Design\/Build\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px; border-bottom:1px solid #E5EEEC; color:#111; font-weight:600;\"\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cdetails style=\"margin:8px 0; border:1px solid #E0EDEB; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none; font-size:14px;\"\u003eWhat does the SP-EVCP-T(W) protect against?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; line-height:1.6; color:#222; background:#ffffff; font-size:14px;\"\u003eIt continuously monitors the incoming single-phase supply voltage and automatically disconnects Line, Neutral, and CPC from the EV charger if a PEN fault or other out-of-range voltage condition is detected for 4 seconds, protecting the vehicle and installation from an unsafe PME supply.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0; border:1px solid #E0EDEB; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none; font-size:14px;\"\u003eDoes this unit require an earth electrode to be installed?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; line-height:1.6; color:#222; background:#ffffff; font-size:14px;\"\u003eNo. The built-in matt:e PEN fault protection technology allows the unit to connect an EV charge point to the existing PME earthing facility without earth rods, avoiding additional groundworks.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0; border:1px solid #E0EDEB; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none; font-size:14px;\"\u003eCan the SP-EVCP-T(W) be used on a three-phase supply?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; line-height:1.6; color:#222; background:#ffffff; font-size:14px;\"\u003eNo. This unit is designed exclusively for single-phase PME supplies in residential settings and must not be used on premises with a three-phase electricity supply.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0; border:1px solid #E0EDEB; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none; font-size:14px;\"\u003eHow is the SP-EVCP-T(W) different from the R, M, and B variants?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; line-height:1.6; color:#222; background:#ffffff; font-size:14px;\"\u003eThe 'T' version has three incoming terminals with no additional built-in protective device. The 'M' version adds a 2-pole MCB, the 'R' version adds a 2-pole Type A RCBO (and is the only variant rated for direct meter tail connection), and the 'B' version adds a 2-pole Type B RCCB plus a single-pole MCB. All other variants must be connected via the Consumer Distribution Board or Garage Board.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0; border:1px solid #E0EDEB; border-radius:6px; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none; font-size:14px;\"\u003eHow long after a fault is cleared before the charger reconnects?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px; line-height:1.6; color:#222; background:#ffffff; font-size:14px;\"\u003eThe contactor remains de-energised until the monitored supply returns to the correct level and remains stable for a continuous period of 3 minutes, after which the EV charger is automatically reconnected.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Matt:e","offers":[{"title":"Default Title","offer_id":65206962061661,"sku":"MATT-SP-EVCP-T-W","price":230.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/matteSinglePhaseMonitoringandProtectionDevicewithTerminalWhite.jpg?v=1783597296","url":"https:\/\/qualityheating.co.uk\/products\/matt-e-single-phase-ev-charger-monitoring-protection-device-with-terminals-white","provider":"AIZO Quality Heating","version":"1.0","type":"link"}