{"product_id":"kamco-one-shot-neutralising-crystals-100g-sachet-anc000-power-flush-waste-water-neutraliser","title":"Kamco One Shot Neutralising Crystals 100g Sachet - ANC000 | Power Flush Waste Water Neutraliser","description":"\u003c!-- SEO Product Name: Kamco One Shot Neutralising Crystals 100g Sachet - ANC000 | Power Flush Waste Water Neutraliser --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eKamco \u003cstrong\u003eOne Shot Neutralising Crystals\u003c\/strong\u003e are a convenient \u003cstrong\u003e100g sachet\u003c\/strong\u003e of neutralising powder used to bring the \u003cstrong\u003ewaste water from a power flush back to a safe pH\u003c\/strong\u003e before disposal. They are designed to be added to the \u003cstrong\u003eClearflow tank\u003c\/strong\u003e once the final power flush 'dump' runs clear, neutralising any acidic residue left behind by \u003cstrong\u003eKamco PowerFlush FX2\u003c\/strong\u003e or Kamco Scalebreaker FX.\u003c\/p\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eEach \u003cstrong\u003esingle-use tube\u003c\/strong\u003e is dosed to treat a standard flush volume, removing the need to measure out loose crystals on site. Circulating the crystals briefly through the system before final disconnection helps \u003cstrong\u003eprotect drains and waste systems\u003c\/strong\u003e from acidic discharge and leaves the heating system ready for inhibitor dosing.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 26px -4px;\"\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e100g\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eSachet Weight\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eOne Shot\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eSingle-Use Tube\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e2.5L FX2\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eNeutralises Per Tube\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003ePost-Flush\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eStage of Use\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eClearflow\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eCompatible Pump\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eANC000\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eManufacturer Code\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eGood to Know: Used at the End of the Flush\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eNeutralising Crystals are added to the \u003cstrong\u003eClearflow tank after the final power flush 'dump'\u003c\/strong\u003e — once the water leaving the dump hose is running clear — and circulated briefly before the system is disconnected.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#E0942A; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003ePlease Note: Dosage Is Matched to FX2 Volume\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eOne 100g sachet neutralises \u003cstrong\u003eevery 2.5 litres of PowerFlush FX2\u003c\/strong\u003e (or Scalebreaker FX) used in the flush. Where a full 5 litre pack of FX2 has been used, two sachets should be dosed accordingly.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#D32F2F; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eImportant: Always Verify Waste Water pH\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eAfter circulating the crystals, \u003cstrong\u003echeck the waste water with pH paper\u003c\/strong\u003e before disposal to confirm neutralisation is complete, in line with good practice for discharging flushing chemical residues to drain.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:0 12px; margin:0 0 8px 0;\"\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003ePre-Measured Single-Use Tube\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eEach \u003cstrong\u003e100g sachet\u003c\/strong\u003e is a fixed, pre-measured dose, removing the guesswork and mess of handling loose neutralising powder on site.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eMatched to FX2 Dosing\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eFormulated to \u003cstrong\u003eneutralise 2.5 litres of PowerFlush FX2\u003c\/strong\u003e per tube, so engineers can dose accurately based on how much flushing liquid was used.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eProtects Drains and Waste Systems\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eNeutralising the acidic residue from FX2 before it's dumped to waste helps \u003cstrong\u003ereduce the risk of acidic discharge\u003c\/strong\u003e reaching drainage systems.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eSimple Clearflow Workflow\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eDesigned to slot directly into the standard Clearflow flushing sequence — added to the tank and \u003cstrong\u003ecirculated for around 5 minutes\u003c\/strong\u003e before the final purge.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eCompact, Easy-to-Stock Format\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eThe tube format is \u003cstrong\u003eeasy to carry in a van stock\u003c\/strong\u003e and simple to store alongside other Kamco flushing chemicals without decanting or measuring.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003ePrepares the System for Inhibitor\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eOnce neutralised and purged, the system is ready for \u003cstrong\u003eSYSTEMSAFE-DM corrosion inhibitor\u003c\/strong\u003e to be circulated and left in place, protecting against future corrosion.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 26px 0;\"\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eProduct Details\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eKamco\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eOne Shot Neutralising Crystals\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eManufacturer Code\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eANC000\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003ePack Format\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eSingle-use sachet \/ tube\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eSachet Weight\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e100g\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eApplication\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eUsed With\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eKamco PowerFlush FX2 and Kamco Scalebreaker FX\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eDosage Rate\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1 sachet per 2.5 litres of FX2 \/ Scalebreaker FX used\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eStage of Use\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eAdded to Clearflow tank after final power flush dump runs clear\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCirculation Time\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eApprox. 5 minutes before final purge\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCompatible Equipment\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eKamco Clearflow power flushing pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eVerification\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eRecommended Check\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eTest waste water with pH paper before disposal\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eNext Step After Neutralising\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eCirculate SYSTEMSAFE-DM inhibitor before disconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eWhat is Kamco One Shot Neutralising Crystals used for?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eIt neutralises the acidic waste water left in the system after a power flush with PowerFlush FX2 or Scalebreaker FX, so it can be safely discharged and the system prepared for inhibitor dosing.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eHow many sachets do I need per flush?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eOne 100g sachet neutralises every 2.5 litres of FX2 or Scalebreaker FX used. If a full 5 litre pack of FX2 was used on the flush, two sachets should be dosed.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eAt what point in the flush should the crystals be added?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eAdd the crystals to the Clearflow tank once the final power flush dump is running clear, then circulate for around 5 minutes before the final purge and disconnection.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eHow do I know the waste water has been fully neutralised?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eCheck the waste water with pH paper after circulating the crystals to confirm neutralisation before disposal.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eWhat should I do after neutralising the system?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eOnce neutralised and purged, circulate SYSTEMSAFE-DM scale and corrosion inhibitor through the system for a further 5 minutes before disconnecting, to protect against future corrosion.\u003c\/div\u003e\n        \u003c\/details\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kamco","offers":[{"title":"Default Title","offer_id":65357943472477,"sku":"ANC000","price":4.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/KamcoOneShotNeutralisingCrystals100gSachet-ANC000PowerFlushWasteWaterNeutraliser.jpg?v=1784886530","url":"https:\/\/qualityheating.co.uk\/products\/kamco-one-shot-neutralising-crystals-100g-sachet-anc000-power-flush-waste-water-neutraliser","provider":"AIZO Quality Heating","version":"1.0","type":"link"}