{"product_id":"kamco-combimag-heat-power-flushing-filter-mi070-magnetic-filter-with-integral-3kw-immersion-heater","title":"Kamco CombiMag Heat Power Flushing Filter - MI070 | Magnetic Filter with Integral 3kW Immersion Heater","description":"\u003c!-- SEO Product Name: Kamco CombiMag Heat Power Flushing Filter - MI070 | Magnetic Filter with Integral 3kW Immersion Heater --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eThe Kamco \u003cstrong\u003eCombiMag HEAT\u003c\/strong\u003e combines a high-power magnetic power flushing filter with an \u003cstrong\u003eintegral 3 kW immersion heater\u003c\/strong\u003e in one compact unit, developed for use when a system's own boiler is not functional or not available to provide heat during the flush. An \u003cstrong\u003e11,000 gauss rare earth magnet\u003c\/strong\u003e removes circulating black iron oxide from the flushing water, while the built-in heater warms the water to improve the effectiveness of the flushing chemical.\u003c\/p\u003e\n\u003cp style=\"line-height:1.7; margin:0 0 16px 0; font-size:16px;\"\u003eLike the standard CombiMag range, it installs \u003cstrong\u003ein line with any power flushing pump\u003c\/strong\u003e and uses a cyclone-construction transparent cylinder with a bypass valve, so the magnet can be inspected and cleaned \u003cstrong\u003ewithout interrupting the flush\u003c\/strong\u003e. The heater is fitted with an \u003cstrong\u003eLED indicator\u003c\/strong\u003e so the engineer can confirm at a glance that it's operating.\u003c\/p\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 26px -4px;\"\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e11,000 Gauss\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMagnet Strength\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e3 kW\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eImmersion Heater\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e240V \/ 50Hz\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eHeater Supply\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eIP55\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eHeater Protection Rating\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003e13A + RCD\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eElectrical Requirement\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:19px; font-weight:700; line-height:1.2;\"\u003eMI070\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eManufacturer Code\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#D32F2F; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eImportant: RCD Protection Required\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eThe integral \u003cstrong\u003e3 kW immersion heater\u003c\/strong\u003e must be supplied through a \u003cstrong\u003e13A fuse used with a residual circuit breaker (RCD) adaptor\u003c\/strong\u003e. This is an electrical safety requirement and should not be bypassed, given the unit operates in direct contact with circulating system water.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#E0942A; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003ePlease Note: For Use When the Boiler Cannot Provide Heat\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eCombiMag HEAT is intended for situations where the \u003cstrong\u003esystem boiler is not functional\u003c\/strong\u003e or cannot be used to warm the flushing water — the integral heater takes over this role so the flushing chemical can still work at an effective temperature.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#E6F4F3; border-left:4px solid #008377CF; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#008377CF; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eGood to Know: Bypass Valve for Uninterrupted Cleaning\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eAs with the rest of the CombiMag range, the \u003cstrong\u003etransparent cylinder and bypass valve\u003c\/strong\u003e allow the magnet to be lifted out, inspected and cleaned during the flush without needing to stop the power flushing pump.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:0 12px; margin:0 0 8px 0;\"\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eMagnetic Debris Removal\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eThe \u003cstrong\u003e11,000 gauss rare earth magnet\u003c\/strong\u003e captures circulating black iron oxide from the flushing water, preventing it from re-entering the heating system or passing back through the boiler.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eIntegral 3 kW Heater\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eA built-in \u003cstrong\u003e3 kW immersion heater\u003c\/strong\u003e warms the flushing water directly at the filter, allowing an effective power flush even when the \u003cstrong\u003esystem boiler is out of action\u003c\/strong\u003e.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eLED Heater Indicator\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eAn \u003cstrong\u003eLED indicator\u003c\/strong\u003e on the unit shows at a glance whether the heater is powered and operating, without needing to check a separate control panel.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eBypass for Mid-Flush Cleaning\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eThe \u003cstrong\u003ebypass valve system\u003c\/strong\u003e lets the magnet be removed, cleaned and reinstalled during the job without interrupting the flow of the power flush.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eReduces Water and Time\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eBy keeping the flushing water clear of circulating debris, CombiMag HEAT helps \u003cstrong\u003ereduce dumping time and water consumption\u003c\/strong\u003e compared to flushing without in-line filtration.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1 1 calc(50% - 12px); min-width:240px; background:#F7FBFA; border:1px solid #E0EDEB; border-radius:8px; padding:16px 18px; margin:0 0 16px 0;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00625D; margin-bottom:6px; font-size:15px;\"\u003eSupplied Ready for Site\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14.5px; color:#2B2B2B; line-height:1.6;\"\u003eThe unit comes with a \u003cstrong\u003eprotective case and 1.5m coupling hose\u003c\/strong\u003e, so it connects straight into the power flushing pump circuit.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 26px 0;\"\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eProduct Details\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eKamco\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eCombiMag HEAT Magnetic Power Flushing Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eManufacturer Code\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eMI070\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eBarcode (EAN)\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e5060134595884\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eSupplied With\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eProtective case and 1.5m coupling hose\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eMagnet Specification\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eMagnet Type\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e11,000 gauss rare earth magnet\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCylinder Construction\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eTransparent cyclone-design cylinder\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCleaning Method\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eBypass valve; magnet removed and wiped clean\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eHeater Specification\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eHeater Type\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eIntegral 3 kW immersion heater\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eElectrical Supply\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e240V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eElectrical Requirement\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e13A fuse with residual circuit breaker (RCD) adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eIndicator\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eLED power indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:10px 16px; font-size:13px; text-transform:uppercase; letter-spacing:0.04em;\"\u003eInstallation\u003c\/td\u003e\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eCompatible Equipment\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eAny power flushing pump\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eConnection Hose Supplied\u003c\/td\u003e\n\u003ctd style=\"background:#FFFFFF; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003e1.5 metre coupling hose\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; font-weight:600; color:#2B2B2B; font-size:14px; width:44%; border-bottom:1px solid #E5E5E5;\"\u003eTypical Use Case\u003c\/td\u003e\n\u003ctd style=\"background:#F0F9F8; padding:9px 16px; color:#2B2B2B; font-size:14px; border-bottom:1px solid #E5E5E5;\"\u003eFlushing when the system boiler cannot provide heat\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eWhat makes CombiMag HEAT different from the standard CombiMag filter?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eCombiMag HEAT adds an integral 3 kW immersion heater to the same magnetic filtration principle, so the flushing water can be heated directly at the filter rather than relying on the system boiler.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eWhen would I need to use CombiMag HEAT instead of a standard CombiMag?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eIt's intended for situations where the system boiler is not functional or otherwise unavailable to warm the flushing water during a power flush.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eWhat electrical supply does the heater need?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eThe 3 kW immersion heater runs from a 240V, 50Hz supply and must be protected by a 13A fuse used with a residual circuit breaker (RCD) adaptor.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eCan the magnet be cleaned without stopping the power flush?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eYes. The bypass valve allows the magnet to be taken out of circulation, inspected and cleaned, then switched back in without interrupting the flushing pump.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin:0 0 10px 0; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:700; padding:12px 18px; font-size:14.5px; cursor:pointer; list-style:none;\"\u003eHow do I know the heater is working?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 18px; font-size:14.5px; color:#2B2B2B; line-height:1.6; background:#FFFFFF;\"\u003eThe unit has a built-in LED indicator that shows when the immersion heater is powered and operating.\u003c\/div\u003e\n        \u003c\/details\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kamco","offers":[{"title":"Default Title","offer_id":65357730283869,"sku":"MI070","price":895.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/KamcoCombiMagHEAT.jpg?v=1784885380","url":"https:\/\/qualityheating.co.uk\/products\/kamco-combimag-heat-power-flushing-filter-mi070-magnetic-filter-with-integral-3kw-immersion-heater","provider":"AIZO Quality Heating","version":"1.0","type":"link"}