{"product_id":"ideal-heating-wall-mounted-hp290-control-box-239386-air-source-heat-pump-electrical-hub-hybrid-cascade-scheduling-diagnostics","title":"Ideal Heating Wall Mounted HP290 Control Box 239386 Air Source Heat Pump Electrical Hub Hybrid Cascade Scheduling Diagnostics","description":"\u003c!-- SEO Product Name: Ideal Heating Wall Mounted HP290 Control Box 239386 Air Source Heat Pump Electrical Hub Hybrid Cascade Scheduling Diagnostics --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#2B2B2B; line-height:1.6;\"\u003e\n\u003cp style=\"font-size:16px; line-height:1.7; color:#2B2B2B; margin:0 0 22px 0;\"\u003eThe \u003cstrong\u003eIdeal Heating Wall Mounted HP290 Control Box\u003c\/strong\u003e is the central electrical hub for an HP290 air source heat pump system. It brings \u003cstrong\u003eevery electrical connection\u003c\/strong\u003e for the heat pump, heating circuits and hot water cylinder into a single, wall-mounted enclosure, cutting installation time and reducing the number of separate junctions an installer needs to wire on site. Built around Ideal's proven heat pump controller, it provides \u003cstrong\u003ein-depth scheduling, connectivity and performance diagnostics\u003c\/strong\u003e, and is suited to standalone HP290 systems as well as hybrid and cascade air source heat pump installations.\u003c\/p\u003e\n    \u003cdiv style=\"display:flex; flex-wrap:wrap; margin:0 -4px 26px -4px;\"\u003e\n        \n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e239386\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eProduct Code\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003eIP20\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eIP Rating\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e200-240VAC\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eRated Voltage\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e16A\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eMax Contactor Current\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e3000W\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eContactor Power Input\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"flex:1; min-width:110px; background:#008377CF; color:#FFFFFF; padding:16px 10px; text-align:center; border-radius:6px; margin:4px;\"\u003e\n            \u003cdiv style=\"font-size:20px; font-weight:700; line-height:1.2;\"\u003e2 Yr\u003c\/div\u003e\n            \u003cdiv style=\"font-size:12px; font-weight:400; opacity:0.92; margin-top:4px;\"\u003eWarranty\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FDECEC; border-left:4px solid #D32F2F; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#D32F2F; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003eImportant: Installation by a competent electrician only\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eAll electrical work on the HP290 Control Box must be carried out by a \u003cstrong\u003ecompetent electrician\u003c\/strong\u003e. The electrical supply must be isolated with appropriate safety measures before work begins, and the heat pump's own electrical installation must be completed and made live \u003cstrong\u003ebefore\u003c\/strong\u003e the supply connection to the Control Box, to reduce the risk of electric shock.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"background:#FFF6E5; border-left:4px solid #E0942A; padding:14px 18px; margin:0 0 18px 0; border-radius:4px;\"\u003e\n        \u003cdiv style=\"font-weight:700; color:#E0942A; margin-bottom:4px; font-size:14px; text-transform:uppercase; letter-spacing:0.03em;\"\u003ePlease Note: Configure the heat pump for this controller before first power-up\u003c\/div\u003e\n        \u003cdiv style=\"font-size:15px; color:#2B2B2B;\"\u003eBefore the HP290 Monobloc is powered up for the first time, the outdoor unit's DIP switch configuration must be set to match the \u003cstrong\u003eControl Box\u003c\/strong\u003e as the connected controller type. Using the wrong DIP switch setting for the controller in use will prevent correct operation.\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"display:grid; grid-template-columns:repeat(2, 1fr); gap:14px; margin:0 0 26px 0;\"\u003e\n        \n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003eSingle hub for every electrical connection\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eBy consolidating heat pump, heating circuit and cylinder wiring into \u003cstrong\u003eone centralised enclosure\u003c\/strong\u003e, the Control Box removes the need for multiple separate junction points, reducing on-site wiring time and the potential for connection errors.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003eSuited to hybrid and cascade systems\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eAs well as standalone HP290 installations, the Control Box is suitable for \u003cstrong\u003ehybrid boiler and air source heat pump systems\u003c\/strong\u003e and for \u003cstrong\u003ecascade heat pump arrangements\u003c\/strong\u003e, giving installers a consistent control hub across different system designs.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003eFast, guided commissioning\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eA built-in \u003cstrong\u003equick start menu\u003c\/strong\u003e steps through commissioning so the heat pump can be up and running and tuned to its most efficient operating parameters in a small number of guided steps, rather than manual parameter-by-parameter setup.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003eFlexible heat emitter compatibility\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eThe Control Box's inbuilt controller is designed to work with \u003cstrong\u003eall common UK heat emitter types\u003c\/strong\u003e, including radiators and underfloor heating, and supports multi-zone configurations.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003ePerformance diagnostics and scheduling\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eBeyond basic on\/off control, the controller provides \u003cstrong\u003escheduling, connectivity and diagnostic feedback\u003c\/strong\u003e, giving homeowners and installers visibility of how efficiently the heat pump system is running.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv style=\"background:#F7FAFA; border:1px solid #D9EDEA; border-radius:6px; padding:16px 18px;\"\u003e\n            \u003cdiv style=\"font-weight:700; color:#00695C; font-size:15px; margin-bottom:6px;\"\u003eWall-mounted for flexible siting\u003c\/div\u003e\n            \u003cdiv style=\"font-size:14px; color:#2B2B2B; line-height:1.55;\"\u003eThis wall-mounted version of the Control Box can be sited away from the heat pump and cylinder as needed, simplifying installations where the electrical hub needs to sit in a utility space or plant room.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 26px 0; border:1px solid #D9EDEA; border-radius:6px; overflow:hidden;\"\u003e\n    \u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:10px 16px; margin:0; border-radius:4px 4px 0 0;\"\u003eGeneral\u003c\/div\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eProduct Number\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e239386\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eDescription\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eHP290 Control Box (Wall Mounted)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eCompatibility\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eIdeal Heating HP290 Air to Water Heat Pumps\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eSystem Suitability\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eStandalone HP290, hybrid boiler + heat pump, and cascade heat pump installations\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eHeat Emitter Suitability\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eRadiators and underfloor heating; suitable for renewable energy systems\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eManufacturer Warranty\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e2 years, when registered within 30 days of installation and serviced annually\u003c\/td\u003e\n            \u003c\/tr\u003e\n\u003c\/table\u003e\n    \u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:10px 16px; margin:0; border-radius:4px 4px 0 0;\"\u003eElectrical\u003c\/div\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eIP Rating\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eIP20\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eRated Voltage\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e200-240 VAC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eMinimum Rated Current (control box)\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e1 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eMaximum Rated Current (contactor)\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e16 A\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eRated Power Input (control box)\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e100 W\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eRated Power Input (contactor)\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e3000 W\u003c\/td\u003e\n            \u003c\/tr\u003e\n\u003c\/table\u003e\n    \u003cdiv style=\"background:#008377CF; color:#FFFFFF; font-weight:700; font-size:15px; padding:10px 16px; margin:0; border-radius:4px 4px 0 0;\"\u003ePhysical\u003c\/div\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eHeight\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e627 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eWidth\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e254 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eDepth\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e147 mm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#F7FAFA;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eWeight\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003e5 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr style=\"background:#FFFFFF;\"\u003e\n                \u003ctd style=\"padding:9px 16px; font-weight:600; color:#2B2B2B; width:45%; border-bottom:1px solid #D9EDEA;\"\u003eMounting Type\u003c\/td\u003e\n                \u003ctd style=\"padding:9px 16px; color:#2B2B2B; border-bottom:1px solid #D9EDEA;\"\u003eWall mounted\u003c\/td\u003e\n            \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin:0 0 8px 0;\"\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:600; font-size:14.5px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat does the HP290 Control Box actually do?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.6;\"\u003eIt's the \u003cstrong\u003ecentral electrical hub\u003c\/strong\u003e for an HP290 heat pump system — bringing together the wiring for the heat pump, heating zones and hot water cylinder in one enclosure, and housing the controller that manages scheduling, diagnostics and heat pump performance.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:600; font-size:14.5px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eCan this be used with a hybrid boiler and heat pump system?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.6;\"\u003eYes. The Control Box is \u003cstrong\u003esuitable for hybrid boiler air source heat pump installations\u003c\/strong\u003e as well as cascade heat pump systems, in addition to standalone HP290 setups.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:600; font-size:14.5px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eDoes the Control Box need to be configured before the heat pump is switched on?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.6;\"\u003eYes. Before the HP290 Monobloc is first powered up, the outdoor unit's \u003cstrong\u003eDIP switch must be set to match the connected controller type\u003c\/strong\u003e (Control Box, Cylinder, or standalone Controller) — refer to the Installation \u0026amp; Maintenance manual for the exact procedure.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:600; font-size:14.5px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWhat's the maximum electrical load the Control Box can switch?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.6;\"\u003eThe internal contactor is rated for a \u003cstrong\u003emaximum of 16A\u003c\/strong\u003e, with a rated power input of 3000W, while the control electronics itself draws a minimum of 1A at 100W.\u003c\/div\u003e\n        \u003c\/details\u003e\n        \u003cdetails style=\"border:1px solid #D9EDEA; border-radius:6px; margin-bottom:10px; overflow:hidden;\"\u003e\n            \u003csummary style=\"background:#008377CF; color:#FFFFFF; font-weight:600; font-size:14.5px; padding:12px 16px; cursor:pointer; list-style:none;\"\u003eWho can install and wire the HP290 Control Box?\u003c\/summary\u003e\n            \u003cdiv style=\"padding:14px 16px; font-size:14.5px; color:#2B2B2B; background:#FFFFFF; line-height:1.6;\"\u003eAll electrical work must be carried out by a \u003cstrong\u003ecompetent electrician\u003c\/strong\u003e, with the supply isolated beforehand and the heat pump's own wiring completed before the Control Box is connected to the electrical supply.\u003c\/div\u003e\n        \u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ideal Heating","offers":[{"title":"Default Title","offer_id":65361723523421,"sku":"239386","price":630.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/IdealHeatingWallMountedHP290ControlBox239386AirSourceHeatPumpElectricalHubHybridCascade.jpg?v=1784897571","url":"https:\/\/qualityheating.co.uk\/products\/ideal-heating-wall-mounted-hp290-control-box-239386-air-source-heat-pump-electrical-hub-hybrid-cascade-scheduling-diagnostics","provider":"AIZO Quality Heating","version":"1.0","type":"link"}