{"product_id":"honeywell-home-t6360b1028-room-thermostat-mains-voltage-wired-room-thermostat-with-heat-anticipator","title":"Honeywell Home T6360B1028 Room Thermostat - Mains Voltage Wired Room Thermostat with Heat Anticipator","description":"\u003cdiv style=\"font-size:16px; font-family:Arial,sans-serif; color:#222; max-width:900px; margin:0 auto; line-height:1.6;\"\u003e\n\n  \u003c!-- Intro --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003eThe \u003cstrong\u003eHoneywell Home T6360B1028\u003c\/strong\u003e is a \u003cstrong\u003emains voltage wired room thermostat\u003c\/strong\u003e built for reliable, automatic temperature control in domestic wet central heating systems. With a \u003cstrong\u003edual diaphragm temperature sensing element\u003c\/strong\u003e, a built-in \u003cstrong\u003eheat anticipator for ±0.5 °C accuracy\u003c\/strong\u003e, and \u003cstrong\u003eRFI suppression\u003c\/strong\u003e, this thermostat is the go-to choice for engineers wanting dependable on\/off control without complexity. It directly switches a \u003cstrong\u003ecirculating pump or boiler\u003c\/strong\u003e, operates \u003cstrong\u003espring-return and motor open\/close zone valves\u003c\/strong\u003e, and can handle \u003cstrong\u003eelectrical heating loads up to 10 A (resistive)\u003c\/strong\u003e — all from a compact 84 × 84 × 37 mm wall-mount unit. The T6360B1028 is also \u003cstrong\u003eBoiler Plus compliant\u003c\/strong\u003e when used alongside a timer or programmer on system boilers.\u003c\/p\u003e\n\n  \u003c!-- Stat strip --\u003e\n  \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:0 0 24px;\"\u003e\n    \u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#fff; border-radius:8px; padding:14px 12px; text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px; font-weight:700;\"\u003e10–30 °C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eSetpoint Range\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#fff; border-radius:8px; padding:14px 12px; text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px; font-weight:700;\"\u003e10 A\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eResistive Load (T3)\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#fff; border-radius:8px; padding:14px 12px; text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px; font-weight:700;\"\u003e±0.5 °C\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eControl Accuracy\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#fff; border-radius:8px; padding:14px 12px; text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px; font-weight:700;\"\u003e230 V\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eMains Voltage\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:130px; background:#008377CF; color:#fff; border-radius:8px; padding:14px 12px; text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:22px; font-weight:700;\"\u003eErP Class I\u003c\/div\u003e\n      \u003cdiv style=\"font-size:13px; margin-top:4px;\"\u003eEnergy Rating\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Red callout: installer requirement --\u003e\n  \u003cdiv style=\"background:#fff5f5; border-left:4px solid #c0392b; border-radius:6px; padding:14px 16px; margin:0 0 16px;\"\u003e\n    \u003cstrong style=\"color:#c0392b;\"\u003e⚠ Installer Notice\u003c\/strong\u003e\u003cbr\u003e\n    This thermostat operates at \u003cstrong\u003e230 V AC mains voltage\u003c\/strong\u003e. Installation must be carried out by a \u003cstrong\u003equalified electrician or competent heating engineer\u003c\/strong\u003e in accordance with the current edition of the IET Wiring Regulations (BS 7671). Ensure the circuit is isolated and proved dead before working on terminals.\n  \u003c\/div\u003e\n\n  \u003c!-- Amber callout: siting guidance --\u003e\n  \u003cdiv style=\"background:#fffbf0; border-left:4px solid #e67e22; border-radius:6px; padding:14px 16px; margin:0 0 16px;\"\u003e\n    \u003cstrong style=\"color:#e67e22;\"\u003e⚠ Siting Guidance\u003c\/strong\u003e\u003cbr\u003e\n    Do \u003cstrong\u003enot\u003c\/strong\u003e position the thermostat where it is exposed to \u003cstrong\u003edirect sunlight, extraneous heat sources, or draughts\u003c\/strong\u003e. False readings from these sources will prevent the thermostat from maintaining accurate room temperature. An interior wall at approximately 1.5 m height, away from windows and radiators, is the recommended location.\n  \u003c\/div\u003e\n\n  \u003c!-- Teal callout: Boiler Plus --\u003e\n  \u003cdiv style=\"background:#e6f4f3; border-left:4px solid #008377; border-radius:6px; padding:14px 16px; margin:0 0 24px;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eⓘ Boiler Plus Compliance\u003c\/strong\u003e\u003cbr\u003e\n    The T6360B1028 is \u003cstrong\u003eBoiler Plus compliant for system boilers\u003c\/strong\u003e when installed alongside a compatible programmer or timer. This satisfies the time and temperature control requirements of Part L of the Building Regulations for England.\n  \u003c\/div\u003e\n\n  \u003c!-- Feature cards --\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; padding:10px 16px; border-radius:6px 6px 0 0; font-weight:700; font-size:15px; margin-bottom:0;\"\u003eKey Features\u003c\/div\u003e\n  \u003cdiv style=\"display:grid; grid-template-columns:repeat(auto-fit,minmax(250px,1fr)); gap:14px; background:#e6f4f3; border:1px solid #c8e6e3; border-top:none; border-radius:0 0 6px 6px; padding:16px; margin:0 0 28px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eDual Diaphragm Sensing\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eThe \u003cstrong\u003edual diaphragm temperature sensing element\u003c\/strong\u003e responds accurately across all load types and applications. Combined with the built-in \u003cstrong\u003eheat anticipator\u003c\/strong\u003e, it achieves a tight control accuracy of \u003cstrong\u003e±0.5 °C at a 3 K\/hour rate of temperature change\u003c\/strong\u003e — reducing temperature overshoot and improving comfort.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eSPDT Changeover Contacts\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eThe \u003cstrong\u003esingle pole, double throw (SPDT) switching action\u003c\/strong\u003e provides \u003cstrong\u003echangeover contacts\u003c\/strong\u003e, making the T6360B1028 equally suited to \u003cstrong\u003eheating and cooling applications\u003c\/strong\u003e. Terminal 3 handles up to \u003cstrong\u003e10 A resistive \/ 3 A inductive\u003c\/strong\u003e; Terminal 4 supports \u003cstrong\u003e6 A resistive \/ 2 A inductive\u003c\/strong\u003e loads.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eRFI Suppression Built In\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eAn integrated \u003cstrong\u003eRFI (radio-frequency interference) suppressor\u003c\/strong\u003e prevents switching noise from the thermostat contacts from disrupting other electronic equipment in the property — important in modern homes with smart devices, Wi-Fi networks, and digital audio equipment nearby.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eDouble Insulated — No Earth Required\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eThe T6360B1028 is \u003cstrong\u003edouble insulated to Class II\u003c\/strong\u003e, meaning \u003cstrong\u003eno earth wire is needed\u003c\/strong\u003e for safe operation. This simplifies installation, particularly in older properties where an earth conductor may not be present at the thermostat position.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eFlexible Mounting Options\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eSuitable for \u003cstrong\u003esurface mounting\u003c\/strong\u003e directly onto the wall or for fitting to a standard \u003cstrong\u003eflush switch box\u003c\/strong\u003e. Fixing screws for both methods are supplied in the box. The slim 37 mm depth keeps the unit unobtrusive wherever it is installed.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9; border:1px solid #c8e6e3; border-radius:6px; padding:16px;\"\u003e\n      \u003cdiv style=\"font-weight:700; color:#008377; border-bottom:2px solid #008377; padding-bottom:6px; margin-bottom:10px;\"\u003eSecure Terminal Clamps\u003c\/div\u003e\n      \u003cp style=\"margin:0; font-size:14px;\"\u003eImproved, \u003cstrong\u003eeasy-to-wire terminals with built-in conductor clamps\u003c\/strong\u003e grip cable conductors securely and resist pull-out — reducing the risk of a loose connection causing intermittent heating faults over the life of the installation.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- Spec table --\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; padding:10px 16px; border-radius:6px 6px 0 0; font-weight:700; font-size:15px;\"\u003eTechnical Specifications\u003c\/div\u003e\n  \u003ctable style=\"width:100%; border-collapse:collapse; margin:0 0 28px; font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; width:42%; border-bottom:1px solid #c8e6e3;\"\u003eManufacturer Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eT6360B1028\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eVoltage Rating\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e230 V AC ±10%, 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eSingle Pole, Double Throw (SPDT) — changeover contacts\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eSwitch Rating — Terminal 3\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e10 A resistive \/ 3 A inductive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eSwitch Rating — Terminal 4\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e6 A resistive \/ 2 A inductive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eTemperature Setpoint Range\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e10 °C to 30 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eControl Accuracy\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e±0.5 °C at 3 K\/hour (with anticipator)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eSensing Element\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eDual diaphragm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eInsulation Class\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eClass II (double insulated — no earth required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eErP Rating\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eClass I\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e84 mm × 84 mm × 37 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e0.19 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eColour\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eWhite\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eSurface or flush switch box\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e−20 °C to +55 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eHumidity\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003e10–90% RH, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600; border-bottom:1px solid #c8e6e3;\"\u003eStandards \/ Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border-bottom:1px solid #c8e6e3;\"\u003eCE marked; EN60730-1, EN55014-1, EN55014-2; Boiler Plus (system boilers with programmer\/timer)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; font-weight:600;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px;\"\u003eHoneywell Home (Resideo)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- FAQ --\u003e\n  \u003cdiv style=\"background:#008377CF; color:#fff; padding:10px 16px; border-radius:6px 6px 0 0; font-weight:700; font-size:15px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3; border-top:none; border-radius:0 0 6px 6px; margin:0 0 28px; overflow:hidden;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat heating systems is the T6360B1028 compatible with?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eThe T6360B1028 is designed for \u003cstrong\u003edomestic wet central heating systems\u003c\/strong\u003e. It can directly switch a \u003cstrong\u003ecirculating pump or boiler\u003c\/strong\u003e, or operate \u003cstrong\u003espring-return and motor open\/motor close zone valves\u003c\/strong\u003e. It can also be used for \u003cstrong\u003ecooling applications\u003c\/strong\u003e by virtue of its SPDT changeover contacts. The maximum switching load is \u003cstrong\u003e10 A resistive \/ 3 A inductive\u003c\/strong\u003e on Terminal 3, making it suitable for the vast majority of residential heating controls.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eDoes the T6360B1028 need an earth wire?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eNo. The T6360B1028 is \u003cstrong\u003edouble insulated (Class II)\u003c\/strong\u003e, so \u003cstrong\u003eno earth wire is required\u003c\/strong\u003e for operation. This makes it easier to install in older properties where an earth conductor is not available at the thermostat location, though all work must still be carried out by a qualified electrician in accordance with BS 7671.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhat is the heat anticipator and why does it matter?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eThe \u003cstrong\u003eheat anticipator\u003c\/strong\u003e is a small resistive heater inside the thermostat that slightly warms the sensing element just before the room reaches the set temperature. This causes the thermostat to switch off the boiler or pump a fraction early, accounting for the residual heat already in the pipework. The result is that the room settles accurately at the target temperature with \u003cstrong\u003eminimal overshoot\u003c\/strong\u003e, delivering the stated \u003cstrong\u003e±0.5 °C control accuracy\u003c\/strong\u003e.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eWhere should the thermostat be positioned for best accuracy?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eThe thermostat should be mounted on an \u003cstrong\u003einterior wall at approximately 1.5 m above floor level\u003c\/strong\u003e, in a room that is representative of the area being controlled (typically the living room or hallway). Avoid positions exposed to \u003cstrong\u003edirect sunlight, draughts, or radiant heat\u003c\/strong\u003e from appliances, as these will cause the thermostat to read incorrectly. Fitting it near an exterior wall or behind a door is also not recommended.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eIs the T6360B1028 Boiler Plus compliant?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eYes — the T6360B1028 satisfies the \u003cstrong\u003eBoiler Plus time and temperature control requirements\u003c\/strong\u003e for \u003cstrong\u003esystem boilers\u003c\/strong\u003e when used alongside a compatible programmer or timer. Note that for \u003cstrong\u003ecombi boilers\u003c\/strong\u003e, Boiler Plus requires additional efficiency measures such as a weather compensator, load compensator, or smart thermostat with automation capability — the T6360 alone does not meet those requirements for combis.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"background:#e6f4f3; padding:12px 16px; font-weight:600; cursor:pointer; list-style:none;\"\u003eCan range stops be fitted to limit the temperature dial?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:12px 16px; font-size:14px;\"\u003eYes. The optional \u003cstrong\u003erange stop accessory (F42006646-001)\u003c\/strong\u003e — a bag of 20 range stops with installation instructions — can be fitted to restrict how far the dial can be turned. This is useful in care homes, rental properties, or commercial settings where you want to prevent users from setting temperatures outside a predetermined range. A \u003cstrong\u003etamper-resistant cover version\u003c\/strong\u003e (T6360B1069) is also available as an alternative.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":64671730303325,"sku":"T6360B1028","price":27.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/HoneywellHomeRoomThermostatt6360b1028.webp?v=1778595996","url":"https:\/\/qualityheating.co.uk\/products\/honeywell-home-t6360b1028-room-thermostat-mains-voltage-wired-room-thermostat-with-heat-anticipator","provider":"AIZO Quality Heating","version":"1.0","type":"link"}