{"product_id":"h6242y-twin-earth-cable-2-5mm-100m-grey","title":"H6242Y Twin \u0026 Earth Cable 2.5mm 100m Grey","description":"\u003c!-- SEO Product Name: Doncaster H6242Y Twin \u0026 Earth Cable 2.5mm 100m Grey | BS 6004 --\u003e\n\u003cdiv style=\"font-size:16px;max-width:900px;margin:0 auto;line-height:1.6;color:#222;font-family:Arial,Helvetica,sans-serif;\"\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eDoncaster H6242Y is a \u003cstrong\u003e2.5 mm² twin and earth cable\u003c\/strong\u003e with a \u003cstrong\u003egrey PVC sheath\u003c\/strong\u003e, made to \u003cstrong\u003eBS 6004\u003c\/strong\u003e and \u003cstrong\u003eBASEC approved\u003c\/strong\u003e. It is a common \u003cstrong\u003efixed wiring cable for the mains supply to an air conditioning unit\u003c\/strong\u003e, such as a spur or final circuit to the isolator and indoor or outdoor unit, and for general domestic and light industrial wiring. Supplied on a \u003cstrong\u003e100 m reel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px;\"\u003eIt has \u003cstrong\u003eplain annealed copper conductors\u003c\/strong\u003e, \u003cstrong\u003ePVC insulation and sheath\u003c\/strong\u003e and a \u003cstrong\u003ebare circuit protective conductor\u003c\/strong\u003e (earth), with brown and blue cores, rated \u003cstrong\u003e300\/500 V\u003c\/strong\u003e. It can be installed in \u003cstrong\u003econduit, trunking or clipped direct\u003c\/strong\u003e in dry or damp premises, and is intended for fixed installation only.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:26px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e2.5 mm²\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eConductor size\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e2 core + earth\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eTwin and earth\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e100 m\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eReel length\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003e300\/500 V\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eVoltage rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003eBS 6004\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eManufacturing standard\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px;background:#008377CF;color:#ffffff;border-radius:8px;padding:16px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:1.25em;font-weight:700;line-height:1.15;\"\u003eBASEC\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.8em;margin-top:6px;opacity:0.95;\"\u003eApproved\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #c0392b;background:#fdf2f2;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#c0392b;margin-bottom:5px;\"\u003e⚠ Electrical work: competent person only\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eFixed wiring must be designed and installed to BS 7671 by a competent person. In dwellings in England, new circuits are notifiable under Part P of the Building Regulations. Size the cable and its protective device for the unit's rated current, the cable length and the installation method.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #e67e22;background:#fdf8f2;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#b35f00;margin-bottom:5px;\"\u003e⚠ Fixed wiring only, protect from sunlight and ground\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eTwin and earth is intended for fixed installation in dry or damp premises. It must not be laid underground, and the grey PVC sheath is not designed for direct sunlight. Run it in conduit or trunking, or choose a suitable outdoor-rated cable, for exposed external runs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:5px solid #008377CF;background:#f0f9f8;border-radius:0 6px 6px 0;padding:14px 18px;margin:18px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00695f;margin-bottom:5px;\"\u003eℹ Earth sleeving and unit manual\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.95em;color:#1f2d2c;\"\u003eThe bare earth conductor must be sleeved green\/yellow at terminations. Check the air conditioning unit's installation manual for the supply cable size, the protective device rating and any isolator requirements.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;margin:22px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e✅\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eBASEC approved\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003e\n\u003cstrong\u003eBASEC approved\u003c\/strong\u003e and manufactured to \u003cstrong\u003eBS 6004:2012\u003c\/strong\u003e for fixed wiring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🔌\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003ePlain annealed copper\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003e\n\u003cstrong\u003ePlain annealed copper conductors\u003c\/strong\u003e with \u003cstrong\u003ebrown and blue\u003c\/strong\u003e cores and a bare earth conductor.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🧱\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003ePVC insulated and sheathed\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003e\n\u003cstrong\u003ePVC insulation and a grey PVC sheath\u003c\/strong\u003e for durable fixed installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🏠\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eDomestic and light industrial\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eSuited to \u003cstrong\u003edomestic and light industrial wiring\u003c\/strong\u003e, including supply circuits to air conditioning units.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e📦\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003e100 m reel\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eA \u003cstrong\u003e100 m reel\u003c\/strong\u003e covers several installations from a single purchase.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px;border:1px solid #d5e8e6;border-top:4px solid #008377CF;border-radius:6px;padding:16px 16px 14px;background:#ffffff;\"\u003e\n\u003cdiv style=\"font-size:1.5em;margin-bottom:6px;\"\u003e🧰\u003c\/div\u003e\n\u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:6px;\"\u003eFlexible installation\u003c\/div\u003e\n\u003cdiv style=\"font-size:0.93em;color:#333;\"\u003eInstall in \u003cstrong\u003econduit, trunking or clipped direct\u003c\/strong\u003e. Minimum bending radius of \u003cstrong\u003e6 x ∅\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"margin:18px 0 26px;border:1px solid #d5e8e6;border-radius:6px;overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eProduct\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eBrand\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eDoncaster Cables\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eType\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eH6242Y twin and earth PVC insulated, PVC sheathed cable with circuit protective conductor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eManufacturer part number\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eH6242Y2.5G100\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eConductor size\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e2.5 mm², 2 cores plus earth\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eReel length\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e100 m\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eSheath colour\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eGrey\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eStandard\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eBS 6004:2012 Table 4\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eApproval\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eBASEC approved\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eConductor\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePlain annealed copper\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eInsulation\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePVC, brown and blue cores\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eCircuit protective conductor\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eBare copper (requires green\/yellow sleeving)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eSheath\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003ePVC, grey\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#008377CF;color:#ffffff;padding:10px 16px;font-weight:700;\"\u003eElectrical and thermal\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eVoltage rating\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e300\/500 V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eMaximum conductor temperature\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#ffffff;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eMinimum bending radius\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003e6 x overall diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;background:#f4faf9;padding:9px 16px;border-bottom:1px solid #e3efee;\"\u003e\n\u003cdiv style=\"flex:1 1 200px;font-weight:700;color:#1f2d2c;padding-right:12px;\"\u003eCurrent carrying capacity\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 280px;color:#333;\"\u003eRefer to Appendix 4 of BS 7671 for your installation method\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color:#008377CF;font-size:1.3em;margin:34px 0 14px;border-bottom:2px solid #008377CF;padding-bottom:6px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdiv style=\"margin:18px 0;\"\u003e\n\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eIs this the right cable for the power supply to an air conditioning unit?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eTwin and earth is the usual fixed wiring cable for mains supply circuits. Check the air conditioning unit's manual for the supply cable size, the protective device and the isolator requirements, and have the circuit designed to BS 7671.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eCan I use it outside or underground?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eIt is intended for fixed installation in dry or damp premises and must not be laid underground. The grey PVC sheath is not designed for direct sunlight, so use conduit or trunking, or an outdoor-rated cable, for exposed external runs.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eDoes the earth need sleeving?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eYes. The bare circuit protective conductor must be sleeved green\/yellow at every termination.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eWhat size cable do I need?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eIt depends on the unit's current, the protective device, the cable length and the installation method. Follow the manufacturer's guidance and BS 7671 current-carrying capacity and voltage-drop requirements.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #008377CF;border-radius:6px;margin:0 0 10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#ffffff;padding:12px 16px;font-weight:700;cursor:pointer;\"\u003eIs it the same as Earthsure?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 16px;background:#ffffff;color:#333;\"\u003eNo. Earthsure is Doncaster's twin and earth with a pre-identified green\/yellow earth. The H6242Y has a bare earth conductor that needs sleeving.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":67575508468102,"sku":"H6242Y2.5G100","price":120.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/H6242YTwin_EarthCable2.5mm100mGrey.jpg?v=1791271048","url":"https:\/\/qualityheating.co.uk\/products\/h6242y-twin-earth-cable-2-5mm-100m-grey","provider":"AIZO Quality Heating","version":"1.0","type":"link"}