{"product_id":"glow-worm-compact-vertical-flue-adaptor","title":"Glow-worm Compact Vertical Flue Adaptor","description":"\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; font-family:Arial, Helvetica, sans-serif; color:#222;\"\u003e\n\u003cdiv style=\"line-height:1.65;color:#222;margin-bottom:20px;\"\u003eThe \u003cstrong\u003eGlow-worm Compact Vertical Flue Adaptor (10031029)\u003c\/strong\u003e is the boiler-specific component required to connect a Glow-worm \u003cstrong\u003eCompact combi boiler\u003c\/strong\u003e to a vertical roof duct. It transitions the boiler's horizontal flue spigot into a \u003cstrong\u003evertical 60\/100mm run\u003c\/strong\u003e, and is the correct adaptor to pair with the Glow-worm Vertical Flue Terminal (0020230604) on Compact range installations.\u003c\/div\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin:18px 0 26px;\"\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e60\/100mm\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eFlue Diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003eCompact\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eBoiler Range\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003eVertical\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eAdaptor Function\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003ePP\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eMaterial\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003ePush-Fit\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eConnection Type\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:110px;background:#008377CF;color:#fff;border-radius:8px;padding:14px 10px;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:19px;font-weight:800;line-height:1.15;\"\u003e1\u003c\/div\u003e\n\u003cdiv style=\"font-size:12px;opacity:.92;margin-top:4px;\"\u003eAdaptor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fdecea;border-left:5px solid #c0392b;border-radius:0 8px 8px 0;padding:14px 18px;margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#8a1f13;font-size:14px;margin-bottom:5px;\"\u003eGas Safe Installation Requirement\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eFlue components must only be fitted by a \u003cstrong\u003eGas Safe registered engineer\u003c\/strong\u003e as part of a compliant, boiler-manufacturer-approved flue system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#fff8e6;border-left:5px solid #b8860b;border-radius:0 8px 8px 0;padding:14px 18px;margin:16px 0;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#7a5900;font-size:14px;margin-bottom:5px;\"\u003eCompact Range Only\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eThis adaptor is specific to the \u003cstrong\u003eGlow-worm Compact combi boiler range\u003c\/strong\u003e. Other Glow-worm ranges (ENERGY, ULTIMATE, EASICOM) use a different vertical flue adaptor part number — check compatibility against your exact boiler model before ordering.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eWhy This Component\u003c\/div\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:1fr 1fr;gap:12px;margin:18px 0 26px;\"\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eBoiler-Specific Fit\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eEngineered specifically for the \u003cstrong\u003eCompact boiler's flue spigot geometry\u003c\/strong\u003e, ensuring a correct, manufacturer-approved seal between the boiler and the vertical roof duct.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eEnables Vertical Termination\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eWithout this adaptor, a Compact boiler's flue cannot be transitioned to a vertical roof penetration — it's the single component that makes a roof termination possible on this range.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003ePush-Fit Installation\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eUses the same tool-free push-fit jointing as the rest of the Glow-worm 60\/100mm flue system, keeping installation quick and consistent.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#e6f4f2;border-left:4px solid #008377CF;border-radius:0 6px 6px 0;padding:14px 16px;\"\u003e\n\u003cdiv style=\"font-weight:700;color:#00594F;font-size:14.5px;margin-bottom:6px;\"\u003eMatches the Wider Flue Range\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#333;line-height:1.6;\"\u003eOnce fitted, the adaptor connects directly to the Glow-worm Vertical Flue Terminal (0020230604) and any further extensions or bends from the same 60\/100mm system.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eTechnical Specification\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto;margin:18px 0 26px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003eGeneral\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eArticle number\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e10031029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eVertical flue adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eFlue diameter\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003e60\/100mm concentric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003ePolypropylene (PP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eCompatible boiler range\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eGlow-worm Compact combi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#008377CF;color:#fff;font-weight:700;padding:9px 14px;font-size:13px;letter-spacing:.04em;text-transform:uppercase;\"\u003eCompatibility\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003ePairs with\u003c\/td\u003e\n\u003ctd style=\"background:#f2faf9;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003eGlow-worm Vertical Flue Terminal 0020230604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;font-weight:600;color:#333;font-size:14px;width:44%;border-bottom:1px solid #e2e2e2;\"\u003eConnection type\u003c\/td\u003e\n\u003ctd style=\"background:#ffffff;padding:9px 14px;color:#222;font-size:14px;border-bottom:1px solid #e2e2e2;\"\u003ePush-fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:18px;font-weight:700;color:#00594F;border-bottom:3px solid #008377CF;padding-bottom:8px;margin:30px 0 14px;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"margin:18px 0 10px;\"\u003e\n\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eWill this adaptor fit any Glow-worm boiler?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eNo. This adaptor is specific to the Compact combi boiler range. Other Glow-worm ranges use a different vertical flue adaptor part number — check your boiler's installation manual before ordering.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eDo I need anything else to complete a vertical flue installation?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eYes — this adaptor connects the boiler to a vertical roof duct, such as the Glow-worm Vertical Flue Terminal (0020230604), which is sold separately along with any required extensions.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eCan I install this myself?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eNo. Flue components must be installed by a Gas Safe registered engineer to ensure the completed system is safe and compliant.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"border:1px solid #cde3e1;border-radius:8px;margin-bottom:10px;overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF;color:#fff;padding:12px 18px;font-weight:700;font-size:14.5px;cursor:pointer;list-style:none;\"\u003eDoes this adaptor work with horizontal flue installations too?\u003c\/summary\u003e\u003cdiv style=\"padding:14px 18px;font-size:14px;color:#333;line-height:1.65;background:#fff;\"\u003eNo, this is a vertical flue adaptor specifically for transitioning to a roof termination. Horizontal installations use a separate standard horizontal flue kit.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Glow-Worm","offers":[{"title":"Default Title","offer_id":65136463774045,"sku":"10031029","price":47.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Glow-wormCompactVerticalFlueAdaptor.jpg?v=1783062496","url":"https:\/\/qualityheating.co.uk\/products\/glow-worm-compact-vertical-flue-adaptor","provider":"AIZO Quality Heating","version":"1.0","type":"link"}