{"product_id":"givenergy-meter-3ph-eastron-v2-with-ct","title":"Eastron SDM630MCT V2 Three Phase CT Energy Meter with CT Clamps — DIN Rail Modbus RS485 MID Certified Solar Import Export","description":"\u003cdiv style=\"font-size:16px;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;max-width:900px;margin:0 auto;line-height:1.6;\"\u003e\n\n  \u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n  \u003cp style=\"margin:0 0 18px;\"\u003e\n    The \u003cstrong\u003eEastron SDM630MCT V2\u003c\/strong\u003e is a \u003cstrong\u003ethree-phase multi-function CT-operated energy meter\u003c\/strong\u003e for DIN rail mounting, supplied complete with \u003cstrong\u003ethree CT clamps\u003c\/strong\u003e. It measures and displays a comprehensive set of electrical parameters — including import and export kWh, voltage, current, power, power factor, frequency, and THD — across single-phase (1P2W) and three-phase (3P3W and 3P4W) supplies. Connectivity via \u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e enables integration with solar inverters, hybrid battery systems, energy management platforms, and building management systems (BMS). The meter is \u003cstrong\u003eMID B+D certified\u003c\/strong\u003e (EU Directive 2014\/32\/EU, certificate 0120\/SGS0142) and ETL registered, meeting the legal accuracy and certification requirements for revenue-grade energy measurement. Rated at \u003cstrong\u003eClass 1.0 accuracy\u003c\/strong\u003e for active energy, with a \u003cstrong\u003e1A or 5A CT input\u003c\/strong\u003e, it works with a wide range of current transformers. DIN rail mounted, \u003cstrong\u003eIP51 rated\u003c\/strong\u003e, and sized at 94.5 × 72 × 65mm for compact panel installation.\n  \u003c\/p\u003e\n\n  \u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin-bottom:20px;\"\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003e3-Phase\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003e3P4W \/ 3P3W \/ 1P2W\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eClass 1.0\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eActive energy accuracy\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eRS485\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eModbus RTU\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003eMID\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eB+D certified\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1;min-width:100px;background:#008377CF;color:#fff;border-radius:6px;padding:12px 10px;text-align:center;\"\u003e\n      \u003cdiv style=\"font-size:19px;font-weight:700;\"\u003e3× CT\u003c\/div\u003e\n      \u003cdiv style=\"font-size:12px;margin-top:3px;\"\u003eClamps included\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── TEAL USE-CASE CALLOUT ─────────────────────────────────────── --\u003e\n  \u003cdiv style=\"border-left:4px solid #008377CF;background:#e6f4f3;padding:10px 16px;margin-bottom:22px;border-radius:0 6px 6px 0;\"\u003e\n    \u003cstrong style=\"color:#005c54;\"\u003eℹ Typical Applications\u003c\/strong\u003e\u003cbr\u003e\n    The SDM630MCT V2 is widely used as a \u003cstrong\u003egrid import\/export meter for solar PV and battery storage systems\u003c\/strong\u003e — providing the hybrid inverter or energy management system with real-time grid consumption and export data for zero-export control, self-consumption optimisation, and tariff scheduling. It is also used in \u003cstrong\u003eEV charging metering\u003c\/strong\u003e, \u003cstrong\u003esub-metering of commercial and industrial premises\u003c\/strong\u003e, and as a \u003cstrong\u003egeneral-purpose three-phase energy monitoring solution\u003c\/strong\u003e wherever Modbus RS485 communication is required. CT installation means no interruption to supply is needed during installation — the clamps simply clip around live cables.\n  \u003c\/div\u003e\n\n  \u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Features \u0026amp; Benefits\n  \u003c\/div\u003e\n  \u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fill,minmax(255px,1fr));gap:12px;background:#e6f4f3;padding:14px;border-radius:0 0 6px 6px;margin-bottom:22px;\"\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ CT Clamp Installation — No Supply Interruption\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eCurrent measurement via \u003cstrong\u003eclip-on CT clamps\u003c\/strong\u003e (three included) means the meter can be installed on live cables without disconnecting supply to the property. The clamps close around the live conductors on each phase at the incoming supply — there is no need to break connections, cut wires, or isolate the supply for the current measurement side of the installation. Only the meter's own auxiliary supply (from the incoming voltage terminals) requires a brief connection.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Bi-Directional — Import \u0026amp; Export\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe SDM630MCT V2 measures \u003cstrong\u003eboth import (from grid) and export (to grid) energy\u003c\/strong\u003e independently — reporting both Imp_kWh and Exp_kWh. Negative power readings are also supported, with a CT reversal indicator for incorrect installation detection. This bi-directional capability is essential for solar PV monitoring, where the meter must distinguish between energy drawn from the grid and energy sent back to it, enabling accurate SEG (Smart Export Guarantee) calculations and self-consumption tracking.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ RS485 Modbus RTU — Universal Integration\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe RS485 Modbus RTU interface communicates with \u003cstrong\u003eup to 64 devices on a single bus at up to 1,000m cable distance\u003c\/strong\u003e, using standard baud rates from 2,400 to 38,400 bps. Modbus is the standard protocol for integration with solar hybrid inverters, battery storage systems, EV charge point management systems, and BMS platforms. The meter's Modbus register map is publicly available, enabling direct integration with custom systems and third-party monitoring platforms.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ 16 Measured Parameters\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe meter's backlit LCD display cycles through \u003cstrong\u003e16 measurement parameters\u003c\/strong\u003e: kWh (import and export), kVArh, kW, kVAr, kVA, voltage (per phase), current (per phase), power factor, frequency, THD (total harmonic distortion), and maximum demand current. All parameters are simultaneously available via Modbus for real-time and historical data access by connected systems. The LCD display enables on-site reading without a connected device.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ MID B+D Certified — Revenue Grade\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eMID (Measuring Instruments Directive) certification to EU Directive 2014\/32\/EU — certificate number \u003cstrong\u003e0120\/SGS0142\u003c\/strong\u003e — confirms the meter meets the legal accuracy and construction requirements for \u003cstrong\u003efiscal (billing) energy measurement\u003c\/strong\u003e in the UK and EU. B+D certification covers both the metering accuracy (Module B) and the quality system (Module D). ETL registration by Intertek confirms compliance with North American standards. This level of certification is required for energy measurement used in billing, sub-metering, and lease arrangements.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Flexible CT Input Options\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eThe standard SDM630MCT V2 accepts \u003cstrong\u003e1A or 5A secondary output CT clamps\u003c\/strong\u003e — the most common standard for metering CTs — enabling use with a wide range of primary current ratings from small domestic to large commercial installations. The meter can also be specified in variants for 40mA, 100mV, and 333mV CT inputs for specialist applications. The CT ratio is programmable via the configuration buttons on the meter, allowing accurate scaling for any current transformer ratio.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ Configurable Pulse Output\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eTwo \u003cstrong\u003econfigurable pulse outputs\u003c\/strong\u003e allow the meter to send energy pulse signals to external counters, data loggers, or monitoring equipment — Pulse Output 2 is fixed at 3,200 impulses\/kWh. This enables integration with systems that accept pulse inputs rather than Modbus, including some older BMS platforms and standalone energy loggers. Pulse outputs are useful for simple energy counting without requiring a Modbus-capable controller.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"background:#f0faf9;border:1px solid #c8e6e3;border-radius:6px;padding:13px;\"\u003e\n      \u003cdiv style=\"font-weight:700;color:#008377CF;margin-bottom:5px;\"\u003e✔ DIN Rail — IP51 — Compact\u003c\/div\u003e\n      \u003cdiv style=\"font-size:14px;\"\u003eStandard 35mm DIN rail mounting at \u003cstrong\u003e94.5 × 72 × 65mm\u003c\/strong\u003e fits neatly in a standard domestic consumer unit, commercial distribution board, or dedicated meter enclosure. IP51 protection provides dust and drip resistance for installation in electrical panels. The compact 4-module width occupies minimal rail space. Operating temperature range –25°C to +55°C covers all UK indoor installation environments.\u003c\/div\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Technical Specifications\n  \u003c\/div\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;margin-bottom:22px;font-size:14px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;width:44%;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eEastron Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eSDM630MCT V2 (Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMeasurement Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3P4W, 3P3W, 1P2W — single or three phase\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eMID B+D (EU 2014\/32\/EU, cert. 0120\/SGS0142); ETL (Intertek); Class 1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIEC 62053-21 \/ EN50470-1\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3 × 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e80%–120% of nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCT Input (rated)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e1A or 5A\u003c\/strong\u003e (standard) — also available as 40mA \/ 100mV \/ 333mV variants\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eCT Clamps Supplied\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e3 × CT clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrequency Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e≤ 2W \/ 10VA per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eActive Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eClass 1 (±1% typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eReactive Energy\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eClass 2\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eVoltage \/ Current\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e0.2% of mid-frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtocol\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eModbus RTU via RS485 (semi-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eBaud Rate\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2,400 \/ 4,800 \/ 9,600 \/ 19,200 \/ 38,400 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eAddress Range\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1–247\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMax Bus Loading\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e64 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMax Communication Distance\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e1,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003ePulse Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e2 — Output 1: configurable; Output 2: 3,200 imp\/kWh (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\" colspan=\"2\"\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e94.5 × 72 × 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003eIP51 (indoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;border-bottom:1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border-bottom:1px solid #c8e6e3;\"\u003e–25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background:#f0faf9;\"\u003e\n\u003ctd style=\"padding:9px 14px;font-weight:600;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;\"\u003e≤ 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n  \u003cdiv style=\"background:#008377CF;color:#fff;font-weight:600;font-size:15px;padding:10px 16px;border-radius:6px 6px 0 0;\"\u003e\n    Frequently Asked Questions\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #c8e6e3;border-top:none;border-radius:0 0 6px 6px;margin-bottom:8px;\"\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhich hybrid inverters and battery systems is this meter compatible with?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe SDM630MCT V2 communicates via standard \u003cstrong\u003eModbus RTU over RS485\u003c\/strong\u003e — the industry-standard protocol for energy meter integration. It is compatible with the vast majority of hybrid inverters and battery storage systems that require an external grid meter, including Sunsynk (Ecco and standard ranges), Solis, Fox ESS, SolarEdge, Fronius, Huawei, Sungrow, and others. Always confirm the specific Modbus register map and CT input specification required by your inverter manufacturer. Some inverters require the meter's Modbus address and baud rate to be set to specific values during commissioning.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eDoes this work on a single-phase (1P2W) property?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eYes — the SDM630MCT V2 supports \u003cstrong\u003esingle-phase two-wire (1P2W) configuration\u003c\/strong\u003e in addition to three-phase configurations. For a single-phase property, only one CT clamp is required (on the live conductor at the incoming supply), and the meter is configured for 1P2W mode via its display buttons. This makes the SDM630MCT V2 a single product suitable for both single and three-phase applications, simplifying procurement.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails style=\"border-bottom:1px solid #c8e6e3;\"\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#f0faf9;\"\u003eWhat does MID certification mean, and is it required?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eMID (Measuring Instruments Directive) certification confirms the meter has been independently assessed and meets the legal requirements for \u003cstrong\u003elegal-for-trade (fiscal) energy measurement\u003c\/strong\u003e in the UK and EU. It is required where the meter reading is used for billing, in sub-metering situations where tenants are charged for energy consumption, or in any contractual energy measurement role. For domestic solar monitoring and self-consumption optimisation (where no billing is involved), MID certification is not legally required — but it does confirm the meter is built and tested to a high accuracy standard. This meter's MID certificate number is 0120\/SGS0142.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary style=\"padding:13px 16px;cursor:pointer;font-weight:600;background:#fff;\"\u003eCan the meter be installed without disconnecting supply?\u003c\/summary\u003e\n      \u003cdiv style=\"padding:11px 16px;font-size:14px;\"\u003eThe CT clamps can be fitted around live cables without disconnecting supply — they simply clip around each phase conductor at the incoming supply point, typically in the consumer unit or distribution board. \u003cstrong\u003eHowever, the meter's voltage sensing terminals must be connected to each phase and neutral\u003c\/strong\u003e, and this wiring must be carried out by a qualified electrician with the supply isolated or under careful live-working conditions. Installation in a consumer unit or distribution board constitutes electrical installation work under Part P of the Building Regulations in England — it must be carried out or certificated by a Part P registered electrician.\u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Eastron","offers":[{"title":"Default Title","offer_id":63263806030173,"sku":"METER-3PH-EASTRON","price":150.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/SolisMeter3PHEastronV2withCT.png?v=1770012854","url":"https:\/\/qualityheating.co.uk\/products\/givenergy-meter-3ph-eastron-v2-with-ct","provider":"AIZO Quality Heating","version":"1.0","type":"link"}