{"product_id":"fox-7kw-l-series-ev-charger-1ph-with-5m-type-2-cable","title":"Fox ESS L Series 7.3kW Single-Phase Tethered EV Charger with 5m Type 2 Cable","description":"\u003cdiv style=\"font-size: 16px; font-family: Arial,Helvetica,sans-serif; color: #1a1a1a; max-width: 900px; margin: 0 auto; line-height: 1.6;\"\u003e\n\u003c!-- ── INTRO ─────────────────────────────────────────────────────── --\u003e\n\u003cp style=\"margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eFox ESS L Series 7.3 kW EV Charger (FE-EV-L07P)\u003c\/strong\u003e is a \u003cstrong\u003esmart, solar-ready single-phase home EV charger\u003c\/strong\u003e with a \u003cstrong\u003e5-metre tethered Type 2 cable\u003c\/strong\u003e. It integrates directly with the Fox ESS inverter and battery ecosystem to enable \u003cstrong\u003egenuine solar self-consumption charging\u003c\/strong\u003e — automatically diverting surplus PV generation to your EV before it is exported to the grid. \u003cstrong\u003eDynamic load balancing\u003c\/strong\u003e continuously monitors your household's live electricity demand and adjusts charging power to prevent tripping your main supply circuit. Control is via three modes: \u003cstrong\u003ePlug \u0026amp; Charge\u003c\/strong\u003e (auto-start on connection), \u003cstrong\u003eRFID card\u003c\/strong\u003e, or the \u003cstrong\u003eFoxESS App\u003c\/strong\u003e with scheduled and solar-optimised charging. Built to \u003cstrong\u003eIP55 and IK08\u003c\/strong\u003e for permanent outdoor installation, and \u003cstrong\u003eOCPP 1.6 \/ 2.0.1 compliant\u003c\/strong\u003e for future commercial or fleet applications.\u003c\/p\u003e\n\u003c!-- ── STAT STRIP ─────────────────────────────────────────────────── --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 10px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; border-radius: 6px; padding: 12px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold;\"\u003e7.3 kW\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; margin-top: 3px;\"\u003eMax output (32A \/ 1PH)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; border-radius: 6px; padding: 12px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold;\"\u003e5 m\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; margin-top: 3px;\"\u003eType 2 tethered cable\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; border-radius: 6px; padding: 12px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold;\"\u003eIP55 \/ IK08\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; margin-top: 3px;\"\u003eWeatherproof \/ impact\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; border-radius: 6px; padding: 12px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold;\"\u003eSolar-ready\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; margin-top: 3px;\"\u003eFox ESS PV linkage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 100px; background: #008377CF; color: #fff; border-radius: 6px; padding: 12px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold;\"\u003eOCPP 1.6\/2.0\u003c\/div\u003e\n\u003cdiv style=\"font-size: 12px; margin-top: 3px;\"\u003eCommercial-ready\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ── RED INSTALLER CALLOUT ─────────────────────────────────────── --\u003e\n\u003cdiv style=\"border-left: 4px solid #c0392b; background: #fff5f5; padding: 10px 16px; margin-bottom: 14px; border-radius: 0 6px 6px 0;\"\u003e\n\u003cstrong style=\"color: #c0392b;\"\u003e⚠ Installer Note\u003c\/strong\u003e — EV charger installation must be carried out by a \u003cstrong\u003equalified electrician registered with an approved competent persons scheme\u003c\/strong\u003e (e.g. NICEIC, NAPIT). A \u003cstrong\u003ededicated 32A circuit with 6–10 mm² supply cable\u003c\/strong\u003e is required. The unit contains an integrated \u003cstrong\u003e6 mA DC residual current detection device (RCD-DD)\u003c\/strong\u003e, but an \u003cstrong\u003eexternal Type A RCCB (40A \/ 30mA)\u003c\/strong\u003e must also be fitted in the consumer unit upstream. Bottom or back cable entry to suit the installation.\u003c\/div\u003e\n\u003c!-- ── AMBER G100 \/ COMPATIBILITY CALLOUT ──────────────────────── --\u003e\n\u003cdiv style=\"border-left: 4px solid #f59e0b; background: #fff8e1; padding: 10px 16px; margin-bottom: 22px; border-radius: 0 6px 6px 0;\"\u003e\n\u003cstrong style=\"color: #b45309;\"\u003e⚡ G100 \u0026amp; DNO Compliance\u003c\/strong\u003e — Confirm G100 compliance status for this specific model with your installer and local DNO before installation. For \u003cstrong\u003esolar self-use charging\u003c\/strong\u003e, the Fox ESS L Series connects to the FoxESS ecosystem via LAN or Wi-Fi — the Fox ESS inverter must be on the same network.\u003c\/div\u003e\n\u003c!-- ── FEATURES GRID ──────────────────────────────────────────────── --\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFeatures \u0026amp; Benefits\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fill,minmax(260px,1fr)); gap: 12px; background: #e6f4f3; padding: 14px; border-radius: 0 0 6px 6px; margin-bottom: 22px;\"\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Solar PV Linkage — Charge from the Sun\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eWhen paired with a Fox ESS inverter, the L07P reads the system's live generation and consumption data and \u003cstrong\u003eautomatically diverts surplus PV power to charge the EV\u003c\/strong\u003e. Rather than exporting cheap excess solar to the grid, you drive on electricity you've generated yourself. No third-party CT clamp or energy meter configuration is required when using native Fox ESS integration.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Dynamic Load Balancing\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eDynamic load management continuously monitors total household electricity demand\u003c\/strong\u003e and modulates the charger's output current in real time to ensure your main supply fuse is never overloaded. When high-draw appliances (ovens, showers, heat pumps) switch on, charging power is automatically reduced to compensate — then restored when demand falls. No manual intervention required.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Three Control Modes\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe L07P offers flexible access control for different household scenarios. \u003cstrong\u003ePlug \u0026amp; Charge\u003c\/strong\u003e starts automatically on cable connection — ideal for a single-occupancy home. \u003cstrong\u003eRFID card\u003c\/strong\u003e authentication restricts use to authorised users. \u003cstrong\u003eApp control\u003c\/strong\u003e via FoxESS allows scheduling, solar-mode activation, and remote monitoring from any location.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Scheduled \u0026amp; Off-Peak Charging\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eSet charging windows via the \u003cstrong\u003eFoxESS app\u003c\/strong\u003e to coincide with off-peak tariff periods (such as Octopus Go, Economy 7, or Agile). The charger will start and stop automatically at the programmed times, maximising the cost savings available from time-of-use electricity tariffs without needing to remember to plug in at the right moment.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ OCPP 1.6 JSON \/ 2.0.1 — Commercial-Ready\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eFull \u003cstrong\u003eOCPP 1.6 JSON and OCPP 2.0.1 protocol support\u003c\/strong\u003e means the L07P can be managed via any OCPP-compatible back-office platform — enabling use in \u003cstrong\u003eworkplace charging schemes, landlord-managed multi-occupancy installations, and fleet charging\u003c\/strong\u003e applications alongside residential use. This future-proofs the investment beyond a straightforward home charger.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ IP55 \/ IK08 — Outdoor Durability\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eIP55\u003c\/strong\u003e (dust-tight and jet-water resistant) and \u003cstrong\u003eIK08\u003c\/strong\u003e (impact resistant to 5 J) make the L07P suitable for \u003cstrong\u003epermanent outdoor wall or post-column mounting\u003c\/strong\u003e without additional enclosure. Rated for operation from \u003cstrong\u003e–25°C to +50°C\u003c\/strong\u003e, it will perform reliably through UK winter conditions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ 6 mA DC RCD-DD — Built-in Safety\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe integrated \u003cstrong\u003e6 mA DC residual current detection device (RCD-DD)\u003c\/strong\u003e meets the IEC 62955 requirement for EV chargers — detecting dangerous DC leakage currents without requiring an expensive Type B RCD in the consumer unit. A standard \u003cstrong\u003eType A RCCB\u003c\/strong\u003e upstream is sufficient, significantly reducing overall installation cost versus older EV charger designs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Wall or Post-Mount, Bottom or Back Entry\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe compact body (\u003cstrong\u003e197 × 196 × 105 mm, 3.9 kg\u003c\/strong\u003e) mounts directly to a wall or to a dedicated floor column. Supply cable entry via the bottom or back of the unit gives flexibility to suit different installation configurations — particularly useful for post-mounted driveways where bottom entry avoids visible cable runs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Fox ESS Ecosystem Integration\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003eThe L07P is designed for native integration with \u003cstrong\u003eFox ESS H1, KH1, and AIO hybrid inverters\u003c\/strong\u003e and their associated battery storage systems. When all three are combined — solar PV, battery storage, and EV charging — the Fox ESS system can intelligently prioritise self-consumption: \u003cstrong\u003echarge the battery first, then the car, then export\u003c\/strong\u003e, or any hierarchy you configure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f0faf9; border: 1px solid #c8e6e3; border-radius: 6px; padding: 13px;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #008377cf; margin-bottom: 5px;\"\u003e✔ Low Standby Consumption\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px;\"\u003e\n\u003cstrong\u003eStandby power consumption of less than 7 W\u003c\/strong\u003e — on a unit that will be connected and live 24 hours a day, this is a meaningful consideration. Lower standby draw than many older or lower-specification home chargers which can consume 15–25 W continuously.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ── SPEC TABLE ─────────────────────────────────────────────────── --\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eTechnical Specifications\u003c\/div\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 22px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; width: 42%; border-bottom: 1px solid #c8e6e3;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eFox ESS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePart Number \/ SKU\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eFE-EV-L07P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eL Series L07P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eRated Output Power\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\u003cstrong\u003e7.3 kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003ePhases\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eSingle-phase (1PH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e230 V AC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eMax Input \/ Output Current\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eConnector \/ Cable\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003cstrong\u003e5 m tethered Type 2\u003c\/strong\u003e (IEC 62196-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eCharge Mode\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eMode 3 — IEC 61851-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eIngress Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\u003cstrong\u003eIP55\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eMechanical Impact\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\u003cstrong\u003eIK08\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eDC Leakage Protection (RCD-DD)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e6 mA (IEC 62955) — integrated; external Type A RCCB still required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eSupply Cable Requirement\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e6–10 mm² recommended for 7.3 kW; dedicated 32A circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eCable Entry\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eBottom or back (installer choice)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eWall mount or floor column \/ post mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eWi-Fi 2.4 GHz, Bluetooth, LAN (Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eOCPP Protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eOCPP 1.6 JSON \/ OCPP 2.0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eControl Modes\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003ePlug \u0026amp; Charge (auto), RFID card, App (FoxESS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eSolar Linkage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eYes — native integration with Fox ESS inverters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eDynamic Load Balancing\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003eYes — real-time adjustment to household demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eStandby Power\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e\u0026lt; 7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e–25°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e197 × 196 × 105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0faf9;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600; border-bottom: 1px solid #c8e6e3;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px; border-bottom: 1px solid #c8e6e3;\"\u003e3.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 9px 14px; font-weight: 600;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 14px;\"\u003eCE \/ UKCA, IEC 61851-1, IEC 62955, IEC 62196-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- ── FAQ ────────────────────────────────────────────────────────── --\u003e\n\u003cdiv style=\"background: #008377CF; color: #fff; font-weight: 600; font-size: 15px; padding: 10px 16px; border-radius: 6px 6px 0 0;\"\u003eFrequently Asked Questions\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c8e6e3; border-top: none; border-radius: 0 0 6px 6px; margin-bottom: 8px;\"\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eDo I need a Fox ESS inverter to use solar charging?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eFor the \u003cstrong\u003enative solar linkage mode\u003c\/strong\u003e, yes — the L07P connects directly to Fox ESS inverters (H1, KH1, AIO) via LAN and reads real-time generation and consumption data from the FoxESS system. If you have a different brand of inverter and want solar-excess charging, you can install a \u003cstrong\u003eFox Smart Meter in the distribution board\u003c\/strong\u003e, which provides the necessary energy data to the charger without needing a Fox inverter. Contact us to confirm compatibility with your existing installation.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eDoes the integrated RCD-DD mean I don't need a special consumer unit protection device?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe built-in \u003cstrong\u003e6 mA DC RCD-DD\u003c\/strong\u003e satisfies the IEC 62955 requirement for DC fault current detection — which means you do \u003cstrong\u003enot\u003c\/strong\u003e need the more expensive Type B RCD in your consumer unit. However, you still need a standard \u003cstrong\u003eType A RCCB (40A\/30mA AC protection)\u003c\/strong\u003e upstream in the consumer unit or sub-board to protect the supply circuit. Your installer will confirm the appropriate protection arrangement for your specific installation.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eWhat is dynamic load balancing and why does it matter?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eMost homes have a main supply fuse rated at 60A, 80A, or 100A. If the EV charger draws its full 32A while other high-demand appliances are also running, you risk tripping the main fuse. \u003cstrong\u003eDynamic load balancing\u003c\/strong\u003e monitors the total current being drawn from the supply in real time and automatically reduces the charger's output to keep the total load within the fuse rating. When other loads decrease, charging power is restored automatically. This allows a full 7.3 kW charge point to coexist with a normal household without risk of supply overload.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-bottom: 1px solid #c8e6e3;\"\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #fff;\"\u003eWhat OCPP support does it have and when would I use it?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe L07P supports \u003cstrong\u003eOCPP 1.6 JSON\u003c\/strong\u003e and \u003cstrong\u003eOCPP 2.0.1\u003c\/strong\u003e — the open protocols used by commercial EV charge point management systems. This means it can be registered with a back-office platform such as those used for \u003cstrong\u003eworkplace charging, OZEV Electric Vehicle Infrastructure Grant schemes, landlord-managed charging\u003c\/strong\u003e, or multi-unit fleet management. For straightforward home use the app is sufficient; OCPP becomes relevant when billing, access management, or reporting are required.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary style=\"padding: 13px 16px; cursor: pointer; font-weight: 600; background: #f0faf9;\"\u003eWhat does the installer need to supply and what circuit is required?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 11px 16px; font-size: 14px;\"\u003eThe installer must run a \u003cstrong\u003ededicated 32A single-phase circuit\u003c\/strong\u003e from the consumer unit to the charger. \u003cstrong\u003e6–10 mm² supply cable\u003c\/strong\u003e is recommended for the 7.3 kW variant. An \u003cstrong\u003eexternal Type A RCCB\u003c\/strong\u003e (40A\/30mA, minimum) must be installed in the consumer unit or a sub-board — a Type B RCD is not required thanks to the integrated RCD-DD. The charger must be \u003cstrong\u003einstalled by a qualified electrician\u003c\/strong\u003e registered with an approved competent persons scheme. Mounting hardware for wall installation and all connectors are supplied with the unit.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fox ESS","offers":[{"title":"Default Title","offer_id":62825006465373,"sku":"FE-EV-L07P","price":335.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/Fox7kWLSeriesEVCharger1PHwith6mType2Cable.jpg?v=1765173141","url":"https:\/\/qualityheating.co.uk\/products\/fox-7kw-l-series-ev-charger-1ph-with-5m-type-2-cable","provider":"AIZO Quality Heating","version":"1.0","type":"link"}