{"product_id":"esbe-ara801-auxiliary-switch-kit-for-ara600-actuators","title":"ESBE ARA801 Auxiliary Switch Kit ARA600 Actuators | 16200700","description":"\u003c!-- SEO Product Name: ESBE ARA801 Auxiliary Switch Kit ARA600 Actuators | 16200700 --\u003e\n\u003cdiv style=\"font-size:16px; max-width:900px; margin:0 auto; color:#222222; line-height:1.6; font-family:Arial, Helvetica, sans-serif;\"\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe \u003cstrong\u003eESBE ARA801 auxiliary switch kit\u003c\/strong\u003e (article \u003cstrong\u003e16200700\u003c\/strong\u003e) adds a \u003cstrong\u003ebuilt-in, adjustable end-position switch\u003c\/strong\u003e to an ESBE ARA600 series rotary actuator. It lets the actuator tell a boiler, heat pump, pump or controller when a diverting or mixing valve has reached a chosen position, so you can \u003cstrong\u003einterlock other plant with valve travel\u003c\/strong\u003e without extra limit switches or external cams.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eThe switch is rated \u003cstrong\u003e6(3) A at 230 V AC\u003c\/strong\u003e and is set with a clever \u003cstrong\u003etool-free method\u003c\/strong\u003e: simply \u003cstrong\u003elift off the turning knob\u003c\/strong\u003e and the \u003cstrong\u003eswitch cam is exposed\u003c\/strong\u003e so the switch point can be set to \u003cstrong\u003eany position\u003c\/strong\u003e in the actuator's 90° travel, with no disassembly. One kit fits the whole \u003cstrong\u003eARA635 to ARA694\u003c\/strong\u003e family, including the popular \u003cstrong\u003eARA645 and ARA655 2-point actuators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:10px; margin:20px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e6(3) A\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eSwitch rating, 230 V AC ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003eAny position\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eSwitch point set anywhere in the 90° travel\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003eNo tools\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eLift the knob to reach the cam\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003eARA600\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eSeries compatibility\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003eNO \/ NC\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eContact connections\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 130px; min-width:130px; text-align:center; background:#f1f8f7; border-top:4px solid #008377CF; padding:12px 8px; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-size:22px; font-weight:bold; color:#008377CF;\"\u003e16200700\u003c\/div\u003e\n\u003cdiv style=\"font-size:13px; color:#444444;\"\u003eESBE article number\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #b3261e; background:#fdecea; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#b3261e; margin-bottom:4px;\"\u003eElectrical safety\u003c\/div\u003e\n\u003cdiv\u003eIsolate the mains supply before removing any actuator cover or working on the wiring. Installation, wiring and commissioning must be carried out by a competent person in accordance with \u003cstrong\u003eBS 7671\u003c\/strong\u003e and the installation instruction supplied with the product. Provide a suitable means of isolation in the supply to the actuator.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #a06a00; background:#fff6e0; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#a06a00; margin-bottom:4px;\"\u003eCheck your actuator reference first\u003c\/div\u003e\n\u003cdiv\u003eThe kit is designed for the \u003cstrong\u003eARA600 series references listed below\u003c\/strong\u003e. Actuators sold with the \u003cstrong\u003eauxiliary switch already fitted\u003c\/strong\u003e (references ending in 6 or 8, such as ARA646 and ARA656) do \u003cstrong\u003enot\u003c\/strong\u003e need this kit.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-left:6px solid #008377CF; background:#f1f8f7; padding:12px 16px; margin:14px 0; border-radius:4px;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:4px;\"\u003eTypical use\u003c\/div\u003e\n\u003cdiv\u003eProving that a \u003cstrong\u003echange-over valve is fully open before a heat source or pump is allowed to run\u003c\/strong\u003e, or signalling valve position back to a controller.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eKey features\u003c\/h3\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; gap:12px; margin:14px 0;\"\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eTool-free setting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eLift off the turning knob to access the \u003cstrong\u003eswitch cam\u003c\/strong\u003e. No tools and no disassembly are needed to set the switch point.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eAdjustable to any position\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eThe switch can be \u003cstrong\u003eset in any position\u003c\/strong\u003e across the actuator's 90° operating range to match your application.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003e6(3) A, 230 V AC contact\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eRated \u003cstrong\u003e6(3) A at 230 V AC ±10%\u003c\/strong\u003e, suitable for switching small pumps, relays and controller inputs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eFits the full ARA600 family\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eCompatible with \u003cstrong\u003eARA635 to ARA639, ARA641 to ARA648, ARA651 to ARA659, ARA661 to ARA664, ARA671 to ARA674 and ARA691 to ARA694\u003c\/strong\u003e.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eRetrofit upgrade\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eTurn a standard \u003cstrong\u003eARA645 or ARA655\u003c\/strong\u003e into an actuator with auxiliary switch on site, without swapping the actuator.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1 1 260px; border:1px solid #cfe5e2; border-top:4px solid #008377CF; border-radius:4px; padding:12px 14px; background:#ffffff;\"\u003e\n\u003cdiv style=\"font-weight:bold; color:#008377CF; margin-bottom:6px;\"\u003e\u003cstrong\u003eCompliant design\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:15px;\"\u003eConforms to \u003cstrong\u003eLVD 2014\/35\/EU, EMC 2014\/30\/EU and RoHS 2011\/65\/EU\u003c\/strong\u003e, with 2 x \u003cstrong\u003eM16x1.5\u003c\/strong\u003e cable entries for the switch wiring.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eProduct identification\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eBrand\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eESBE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eModel\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eARA801 auxiliary switch kit for ARA600\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eManufacturer part number\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e16200700\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eProduct type\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eAdd-on auxiliary switch kit for rotary actuators\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eElectrical\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSwitch rating\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e6(3) A, 230 V AC ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eContact connections\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eNO and NC contact connections, per the ESBE wiring diagram\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eCable entries\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003e2 x M16x1.5\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eSetting and fitting\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eSwitch point adjustment\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eAny position within the actuator travel, set by lifting off the turning knob to reach the switch cam\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eTools needed to set\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eNone\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eInstallation instruction\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eESBE document 9814 0310\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eCompatible actuators\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA635 to ARA639\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA641 to ARA648\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA651 to ARA659\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA661 to ARA664\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA671 to ARA674\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#ffffff; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eARA691 to ARA694\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eCompatible\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #008377CF; border-radius:4px; margin:14px 0; overflow:hidden;\"\u003e\n\u003cdiv style=\"background:#008377CF; color:#ffffff; font-weight:bold; padding:8px 14px;\"\u003eCompliance\u003c\/div\u003e\n\u003cdiv style=\"display:flex; flex-wrap:wrap; padding:8px 14px; background:#f1f8f7; border-bottom:1px solid #d9e8e6;\"\u003e\n\u003cdiv style=\"flex:1 1 200px; font-weight:bold; color:#008377CF;\"\u003eDirectives\u003c\/div\u003e\n\u003cdiv style=\"flex:2 1 260px;\"\u003eLVD 2014\/35\/EU, EMC 2014\/30\/EU, RoHS 2011\/65\/EU\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size:20px; color:#008377CF; margin:30px 0 12px 0; padding-bottom:6px; border-bottom:2px solid #008377CF; font-weight:bold;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eWhich actuators does the ARA801 fit?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eIt fits ESBE \u003cstrong\u003eARA600 series\u003c\/strong\u003e actuators in the ranges \u003cstrong\u003eARA635 to ARA639, ARA641 to ARA648, ARA651 to ARA659, ARA661 to ARA664, ARA671 to ARA674 and ARA691 to ARA694\u003c\/strong\u003e. This includes the 2-point \u003cstrong\u003eARA645\u003c\/strong\u003e and \u003cstrong\u003eARA655\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eDo I need it if my actuator is an ARA646 or ARA656?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eNo. Those references are supplied with the \u003cstrong\u003eauxiliary switch pre-mounted\u003c\/strong\u003e. The ARA801 is the optional kit for actuators without one.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eHow do I set the switch point?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003e\n\u003cstrong\u003eLift off the turning knob\u003c\/strong\u003e on the front of the actuator. The \u003cstrong\u003eswitch cam\u003c\/strong\u003e is then accessible and can be set to the required position. \u003cstrong\u003eNo tools or disassembly\u003c\/strong\u003e are required.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eWhat load can the switch carry?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eThe switch is rated \u003cstrong\u003e6(3) A at 230 V AC ±10%\u003c\/strong\u003e. Do not exceed this rating; use a relay or contactor for larger loads.\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails style=\"border:1px solid #008377CF; border-radius:6px; margin:8px 0; overflow:hidden;\"\u003e\u003csummary style=\"background:#008377CF; color:#ffffff; padding:10px 14px; cursor:pointer; font-weight:bold;\"\u003eIs wiring information included?\u003c\/summary\u003e\u003cdiv style=\"padding:12px 14px;\"\u003eYes. ESBE publishes an installation instruction for the kit (document 9814 0310) showing the \u003cstrong\u003eNO \/ NC wiring connections\u003c\/strong\u003e and cable entries. Always follow it and isolate the supply before working.\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e","brand":"ESBE","offers":[{"title":"Default Title","offer_id":67580946088326,"sku":"ARA801","price":43.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/2051\/3629\/files\/esbe-actuator-30s-60s.jpg?v=1791356731","url":"https:\/\/qualityheating.co.uk\/products\/esbe-ara801-auxiliary-switch-kit-for-ara600-actuators","provider":"AIZO Quality Heating","version":"1.0","type":"link"}